Influence of the fixation stability on the healing time - A numerical study of a patient-specific fracture healing process

被引:59
|
作者
Wehner, Tim [1 ]
Claes, Lutz [1 ]
Niemeyer, Frank [1 ,2 ]
Nolte, Daniel [2 ]
Simon, Ulrich [1 ,2 ]
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech, D-89081 Ulm, Germany
[2] Univ Ulm, Sci Comp Ctr Ulm, D-89081 Ulm, Germany
关键词
Fixation stability; External fixator; Interfragmentary movement; Fracture healing; Mechanobiology; Numerical simulation; TISSUE DIFFERENTIATION; MECHANICAL-PROPERTIES; BIOPHYSICAL STIMULI; OSTEOTOMY GAP; FUZZY-LOGIC; BONE; MODEL; SIZE; SHEEP; VASCULARIZATION;
D O I
10.1016/j.clinbiomech.2010.03.003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The healing outcome of long bone fractures is strongly influenced by the interfragmentary movement of the bone fragments. This depends on the fixation stability, the optimum value of which is still not known. The aim of this study was to simulate a patient-specific human healing process using a numerical algorithm and to retrospectively analyse the influence of the fixation stability on the healing time. Methods: The healing simulation was processed as an initial value problem. This was iteratively solved based on two mechanical (invariants of the strain tensor, calculated through a finite element analysis) and five biological state variables (local tissue composition and blood perfusion) using a previously published fuzzy logic algorithm. For validation purposes, the calculated interfragmentary movement was compared to in vivo measurements of this patient. By changing clinically adjustable parameters of the fixation device, the influence of the fixation stability on the healing time was analysed. Finding: The time course showed good agreement of the interfragmentary movement compared with the in vivo measurements. The predicted healing time was strongly influenced by the fixation stability, i.e. by changing the parameters of the fixation device, it was possible to significantly reduce the healing time. Interpretation: The time to heal could be greatly reduced by modification of the fixator design, i.e. increasing the fixation stiffness. When using external fixation devices, this could be achieved by decreasing the free bending length of the pins, using a stiff fixation body and a stiff connection between the pins and the body. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:606 / 612
页数:7
相关论文
共 50 条
  • [11] A method for optimal fit of patient-specific fracture fixation plates
    Harith, Hazreen
    Malekani, Javad
    Schmutz, Beat
    Schuetz, Michael
    Yarlagadda, Prasad K. D. V.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2016, 230 (01) : 282 - 290
  • [12] Timely fracture-healing requires optimization of axial fixation stability
    Epari, Devakara R.
    Kassi, Jean-Pierre
    Schell, Hanna
    Duda, Georg N.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (07): : 1575 - 1585
  • [13] INFLUENCE OF REMOVAL OF EXTERNAL FIXATION AFTER VARIOUS PERIODS OF TIME IN EXPERIMENTAL FRACTURE-HEALING
    TERJESEN, T
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03): : 386 - 386
  • [15] Simulation of fracture healing using cellular automata - (Influence of operation conditions on healing result in external fixation)
    Kawamura, S
    Kamitani, K
    Iwatsubo, T
    Matuda, M
    Kurosaka, M
    Yoshiya, S
    Muratsu, H
    Hofer, EP
    JSME INTERNATIONAL JOURNAL SERIES A-SOLID MECHANICS AND MATERIAL ENGINEERING, 2005, 48 (02) : 57 - 64
  • [16] Influence of Mechanical Fixation on Angiogenesis during Bone Healing Process
    Zhou, Zhilun
    Zhao, Feng
    Yan, Yang
    Yuan, Zhen
    Yang, Guanzhong
    Yu, Hao
    Su, Hao
    Zhang, Tao
    Fan, Yubo
    1ST GLOBAL CONFERENCE ON BIOMEDICAL ENGINEERING & 9TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 47 : 111 - +
  • [17] EFFECT OF DELAYED INTERNAL FIXATION ON FRACTURE HEALING - AN EXPERIMENTAL STUDY
    PIEKARSK.K
    WILEY, AM
    BARTELS, JE
    ACTA ORTHOPAEDICA SCANDINAVICA, 1969, 40 (05): : 543 - &
  • [18] An external fixation method and device to study fracture healing in rats
    Mark, H
    Bergholm, J
    Nilsson, A
    Rydevik, B
    Strömberg, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 2003, 74 (04): : 476 - 482
  • [19] Does the level of an intracapsular femoral fracture influence fracture healing after internal fixation? A study of 411 patients
    Rajan, DT
    Parker, MJ
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2001, 32 (01): : 53 - 56
  • [20] Renal impairment and time to fracture healing following surgical fixation of distal radius fracture
    Lai, Sean Han Sheng
    Tang, Camelia Qian Ying
    Chiow, Si Min
    Chia, Dawn Sinn Yii
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (04): : 1329 - 1334