Analysis of steady state and non-steady state corneal permeation of diclofenac

被引:26
|
作者
Mohapatra, Rajaram [1 ]
Mallick, Subrata [1 ]
Nanda, Ashirbad [1 ]
Sahoo, Rudra N. [1 ]
Pramanik, Arunima [1 ]
Bose, Anindya [1 ]
Das, Debajyoti [1 ]
Pattnaik, Lolly [2 ,3 ]
机构
[1] Siksha O Anusandhan Univ, Sch Pharmaceut Sci, Bhubaneswar 751003, Orissa, India
[2] Siksha O Anusandhan Univ, Inst Med Sci, Bhubaneswar 751003, Orissa, India
[3] Siksha O Anusandhan Univ, Sum Hosp, Bhubaneswar 751003, Orissa, India
关键词
CONTROLLED DRUG-DELIVERY; IN-VITRO PERFORMANCE; PHARMACOKINETIC MODEL; PERCUTANEOUS-ABSORPTION; LOTEPREDNOL ETABONATE; STATISTICAL MOMENTS; TRANSIENT DIFFUSION; DISSOLUTION TIME; THERMAL-ANALYSIS; RELEASE;
D O I
10.1039/c6ra03604j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The present study was undertaken for characterization of the steady state and non steady state corneal permeation kinetics of diclofenac potassium (DCP) using statistical moment theory. Hydrogel films containing DCP in a hydroxypropyl methylcellulose (HPMC) matrix were prepared by a casting method, and the steady state and non-steady state corneal permeation parameters of diclofenac were evaluated using statistical moment analysis. The correlation coefficient (r), coefficient of non-determination and standard error of estimate (SEE) results indicated a good Level "A" correlation between in vitro dissolution and ex vivo steady state permeation of DCP from all the hydrogel formulations. SEM, XRD and DSC studies suggested the inhibition of the crystal growth and partial amorphization of diclofenac in the film. One way analysis of variance (ANOVA) followed by Dunnett's test revealed that all the hydrogel films containing plasticizer (L2, L3 and L4) show very high significant difference of extent of permeation in non-steady state (EPN), extent of permeation in lag time (EPL), extent of permeation in steady state (EPS) and total amount permeated in 360 min (TAP) from the control film containing no plasticizer (L1) related to highly improved permeation. Marked anti-inflammatory activity has been observed after application of the hydrogel film. The binding configuration of DCP-HPMC using docking calculations indicated drug-excipient interaction at the molecular level. Steady state and non-steady state corneal permeation parameters have been evaluated successfully using statistical moment analysis, and highly improved permeation has been observed when compared to the parameters of the film with the control.
引用
收藏
页码:31976 / 31987
页数:12
相关论文
共 50 条
  • [21] Implicit scheme for contact analysis in non-steady state forming
    Department of Applied Mechanics, IIT Delhi, Hauz Khas, New Delhi, India
    不详
    Eng Comput (Swansea Wales), 7 (908-924):
  • [22] Non-steady state rolling contact and corrugations
    Knothe, K
    ROLLING CONTACT PHENOMENA, 2000, (411): : 203 - 276
  • [23] COUNTERCURRENT TRANSFER PROCESSES IN THE NON-STEADY STATE
    JASWON, MA
    SMITH, W
    PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1954, 225 (1161): : 226 - 244
  • [24] NON-STEADY STATE NATURE OF DROPLET COMBUSTION
    NURUZZAMAN, AS
    BEER, JM
    COMBUSTION SCIENCE AND TECHNOLOGY, 1971, 3 (01) : 17 - +
  • [26] Energy utilization in cattle with steady state and non-steady state methods: the importance of thermal neutrality
    Schaefer, A. L.
    Ominski, K.
    Thompson, S.
    Crow, G.
    Bench, C.
    Colyn, J.
    Rodas-Gonzalez, A.
    Maharjan, D.
    Bollum, R.
    Cook, N. J.
    Basarab, J.
    von Gaza, H.
    HELIYON, 2018, 4 (10):
  • [27] STEADY STATE AND NON-STEADY STATE OF A SEMICONDUCTOR-FERROELECTRIC IN THE PRESENCE OF AN ELECTRIC FIELD.
    Kachlishvili, T.Z.
    Soviet physics journal, 1987, 30 (06): : 524 - 538
  • [28] Steady-state and non-steady state operation of counter-current chromatography devices
    Kostanyan, Artak E.
    Ignatova, Svetlana N.
    Sutherland, Ian A.
    Hewitson, Peter
    Zakhodjaeva, Yulya A.
    Erastov, Andrey A.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1314 : 94 - 105
  • [29] THE THEORY OF NON-STEADY STATE FRACTURE KINETICS ANALYSIS .2. NON-STEADY STATE CRACK-PROPAGATION IN STRESS-CORROSION CRACKING
    KRAUSZ, AS
    MSHANA, J
    KRAUSZ, K
    ENGINEERING FRACTURE MECHANICS, 1980, 13 (04) : 759 - 766
  • [30] Comparing Steady State to Time Interval and Non-Steady State Measurements of Resting Metabolic Rate
    Irving, Chelsea Jayne
    Eggett, Dennis L.
    Fullmer, Susan
    NUTRITION IN CLINICAL PRACTICE, 2017, 32 (01) : 77 - 83