Extraction of Ascorbate Oxidase from Cucurbita maxima by Continuous Process in Perforated Rotating Disc Contactor Using Aqueous Two-Phase Systems

被引:14
|
作者
Porto, T. S. [1 ,2 ]
Marques, P. P. [1 ]
Porto, C. S. [1 ]
Moreira, K. A. [1 ,3 ]
Lima-Filho, J. L. [1 ]
Converti, A. [4 ]
Pessoa, A. [2 ]
Porto, A. L. F. [1 ,5 ]
机构
[1] Univ Fed Pernambuco, LIKA, BR-50670901 Recife, PE, Brazil
[2] Univ Sao Paulo, Dept Biochem & Pharmaceut Technol, Sao Paulo, Brazil
[3] Univ Fed Rural Pernambuco, Acad Unit Garanhuns, Recife, PE, Brazil
[4] Univ Genoa, Dept Chem & Proc Engn, Genoa, Italy
[5] Univ Fed Rural Pernambuco, Dept Anim Morphol & Physiol, Recife, PE, Brazil
基金
巴西圣保罗研究基金会;
关键词
Ascorbate oxidase; ATPS; Continuous extraction; Cucurbita maxima; PRDC; MASS-TRANSFER; PROTEIN EXTRACTION; FERMENTED BROTH; CRUDE EXTRACT; RECOVERY; HYDRODYNAMICS; PERFORMANCE; PREDICTION; COLUMN;
D O I
10.1007/s12010-009-8631-y
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The ascorbate oxidase is the enzyme used to determine the content of ascorbic acid in the pharmaceutical and food industries and clinics analyses. The techniques currently used for the purification of this enzyme raise its production cost. Thus, the development of alternative processes and with the potential to reduce costs is interesting. The application of aqueous two-phase system is proposed as an alternative to purification because it enables good separation of biomolecules. The objective of this study was to determine the conditions to continuously pre-purify the enzyme ascorbate oxidase by an aqueous two-phase system (PEG/citrate) using rotating column provided with perforated discs. Under the best conditions (20,000 g/mol PEG molar mass, 10% PEG concentration, and 25% citrate concentration), the system showed satisfactory results (partition coefficient, 3.35; separation efficiency, 54.98%; and purification factor, 1.46) and proved suitable for the pre-purification of ascorbate oxidase in continuous process.
引用
收藏
页码:1057 / 1064
页数:8
相关论文
共 50 条
  • [41] Extraction of caffeine using aqueous two-phase systems containing ionic liquid and sorbitol
    Yazdabadi, Atousa
    Shahriari, Shahla
    Salehifar, Mania
    FLUID PHASE EQUILIBRIA, 2019, 502
  • [42] Extraction and Purification of Lipoxygenase from Soybean Using Aqueous Two-Phase System
    Lakshmi, M. C.
    Madhusudhan, M. C.
    Raghavarao, K. S. M. S.
    FOOD AND BIOPROCESS TECHNOLOGY, 2012, 5 (01) : 193 - 199
  • [43] Bioaffinity extraction of glucoamylase in aqueous two-phase systems using starch as free bioligand
    de Gouveia, T
    Kilikian, BV
    JOURNAL OF CHROMATOGRAPHY B, 2000, 743 (1-2): : 241 - 246
  • [44] Malic acid extraction from aqueous solution by using aqueous two-phase system method
    Masoumi, Hadiseh
    Penchah, Hamid Ramezanipour
    Gilani, Hossein Ghanadzadeh
    Shaldehi, Tahereh Jangjooye
    RESULTS IN CHEMISTRY, 2019, 1
  • [45] Optimization of extraction of luciferase from fireflies (Photinus pyralis) using aqueous two-phase extraction
    Priyanka, B. S.
    Rastogi, Navin K.
    Raghavarao, K. S. M. S.
    Thakur, M. S.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 118 : 40 - 48
  • [46] Application of aqueous two-phase systems for the extraction of pharmaceutical compounds from water samples
    Assis, Roberta C.
    Mageste, Aparecida B.
    de Lemos, Leandro R.
    Orlando, Ricardo Mathias
    Rodrigues, Guilherme D.
    JOURNAL OF MOLECULAR LIQUIDS, 2020, 301
  • [47] Separation and purification of laccases from two different fungi using aqueous two-phase extraction
    Prinz, Axel
    Hoenig, Jacqueline
    Schuettmann, Ina
    Zorn, Holger
    Zeiner, Tim
    PROCESS BIOCHEMISTRY, 2014, 49 (02) : 335 - 346
  • [48] New process design for plasmid isolation using aqueous two-phase systems.
    Kula, MR
    Frerix, A
    Mueller, M
    Hubbuch, J
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U183 - U184
  • [49] Integrated process for purification of capsaicin using aqueous two-phase systems based on ethanol
    Cienfuegos, N. E. C.
    Santos, P. L.
    Garcia, A. R.
    Soares, C. M. F.
    Lima, A. S.
    Souza, R. L.
    FOOD AND BIOPRODUCTS PROCESSING, 2017, 106 : 1 - 10
  • [50] Continuous-flow fractionation of animal cells in microfluidic device using aqueous two-phase extraction
    Nam, KH
    Chang, WJ
    Hong, H
    Lim, SM
    Kim, DI
    Koo, YM
    BIOMEDICAL MICRODEVICES, 2005, 7 (03) : 189 - 195