Clinical-oriented Three-dimensional Gait Analysis Method for Evaluating Gait Disorder

被引:24
|
作者
Mukaino, Masahiko [1 ]
Ohtsuka, Kei [2 ]
Tanikawa, Hiroki [2 ]
Matsuda, Fumihiro [2 ]
Yamada, Junya [3 ]
Itoh, Norihide [4 ]
Saitoh, Eiichi [1 ]
机构
[1] Fujita Hlth Univ, Sch Med, Dept Rehabil Med, Toyoake, Aichi, Japan
[2] Fujita Hlth Univ, Sch Hlth Sci, Fac Rehabil, Toyoake, Aichi, Japan
[3] Fujita Hlth Univ Hosp, Dept Rehabil, Toyoake, Aichi, Japan
[4] Kyoto Prefectural Univ Med, Grad Sch Med Sci, Dept Adv Rehabil Med, Kyoto, Japan
来源
关键词
Behavior; Issue; 133; three-dimensional gait analysis; gait disorder; stroke; rehabilitation; treadmill; clinical evaluation; STROKE PATIENTS; POSTSTROKE; WALKING; INDIVIDUALS; HEMIPLEGIA; SPEED; TRUNK;
D O I
10.3791/57063
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Three-dimensional gait analysis (3DGA) is shown to be a useful clinical tool for the evaluation of gait abnormality due to movement disorders. However, the use of 3DGA in actual clinics remains uncommon. Possible reasons could include the time-consuming measurement process and difficulties in understanding measurement results, which are often presented using a large number of graphs. Here we present a clinician-friendly 3DGA method developed to facilitate the clinical use of 3DGA. This method consists of simplified preparation and measurement processes that can be performed in a short time period in clinical settings and intuitive results presentation to facilitate clinicians' understanding of results. The quick, simplified measurement procedure is achieved by the use of minimum markers and measurement of patients on a treadmill. To facilitate clinician understanding, results are presented in figures based on the clinicians' perspective. A Lissajous overview picture (LOP), which shows the trajectories of all markers from a holistic viewpoint, is used to facilitate intuitive understanding of gait patterns. Abnormal gait pattern indices, which are based on clinicians' perspectives in gait evaluation and standardized using the data of healthy subjects, are used to evaluate the extent of typical abnormal gait patterns in stroke patients. A graph depicting the analysis of the toe clearance strategy, which depicts how patients rely on normal and compensatory strategies to achieve toe clearance, is also presented. These methods could facilitate implementation of 3DGA in clinical settings and further encourage development of measurement strategies from the clinician's point of view.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Reliability of a method for analyzing knee kinematics during three-dimensional gait
    Labbe, David R.
    Hagemeister, Nicola
    Tremblay, Mathieu
    de Guise, Jacques
    GAIT & POSTURE, 2008, 28 (01) : 170 - 174
  • [22] Gait characteristics of children with Williams syndrome with impaired visuospatial recognition: a three-dimensional gait analysis study
    Ito, Yuji
    Ito, Tadashi
    Kurahashi, Naoko
    Ochi, Nobuhiko
    Noritake, Koji
    Sugiura, Hideshi
    Mizuno, Seiji
    Kidokoro, Hiroyuki
    Natsume, Jun
    Nakamura, Miho
    EXPERIMENTAL BRAIN RESEARCH, 2020, 238 (12) : 2887 - 2895
  • [23] A simple controller for the prediction of three-dimensional gait
    Fluit, R.
    van der Krogt, M. M.
    van der Kooij, H.
    Verdonschot, N.
    Koopman, H. F. J. M.
    JOURNAL OF BIOMECHANICS, 2012, 45 (15) : 2610 - 2617
  • [24] Gait characteristics of children with Williams syndrome with impaired visuospatial recognition: a three-dimensional gait analysis study
    Yuji Ito
    Tadashi Ito
    Naoko Kurahashi
    Nobuhiko Ochi
    Koji Noritake
    Hideshi Sugiura
    Seiji Mizuno
    Hiroyuki Kidokoro
    Jun Natsume
    Miho Nakamura
    Experimental Brain Research, 2020, 238 : 2887 - 2895
  • [25] Biomechanical analysis of the three-dimensional foot structure during gait: A basic tool for clinical applications
    Gefen, A
    Megido-Ravid, M
    Itzchak, Y
    Arcan, M
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (06): : 630 - 639
  • [26] Evaluation of a multibody kinematics optimization method for three-dimensional canine pelvic limb gait analysis
    Lin, Cheng-Chung
    Wu, Ching-Ho
    Chou, Po-Yen
    Wang, Shi-Nuan
    Hsu, Wei-Ru
    Lu, Tung-Wu
    BMC VETERINARY RESEARCH, 2020, 16 (01)
  • [27] Evaluation of a multibody kinematics optimization method for three-dimensional canine pelvic limb gait analysis
    Cheng-Chung Lin
    Ching-Ho Wu
    Po-Yen Chou
    Shi-Nuan Wang
    Wei-Ru Hsu
    Tung-Wu Lu
    BMC Veterinary Research, 16
  • [28] A wireless MEMS-sensor module for three-dimensional gait analysis
    Yin, Zhijian
    Ning, Haojie
    Yin, Jibin
    Inoue, Yoshio
    Liu, Tao
    ICIC Express Letters, 2014, 8 (04): : 1165 - 1170
  • [29] Three-dimensional lubrication model of an artificial hip joint with gait analysis
    Mechanical Engineering Department, Virginia Commonwealth University, Richmond, VA, United States
    不详
    ASME Bioeng Div Publ BED, (143-144):
  • [30] Bilateral and three-dimensional analysis of elderly able-bodied gait
    Sadeghi, H
    Zabjek, KF
    Prince, F
    Sadeghi, S
    Labelle, H
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 108 (1-2) : 59 - 59