Comparison of Dual to Single Contrast Bolus Magnetic Resonance Myocardial Perfusion Imaging for Detection of Significant Coronary Artery Disease

被引:10
|
作者
Groothuis, Jan G. J. [1 ,3 ,4 ]
Kremers, Frans P. P. J. [2 ]
Beek, Aernout M. [1 ,3 ]
Brinckman, Stijn L. [1 ,3 ]
Tuinenburg, Alvin C. [1 ]
Jerosch-Herold, Michael [5 ]
van Rossum, Albert C. [1 ,3 ]
Hofman, Mark B. M. [2 ,3 ]
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Cardiol, NL-1081 HV Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Phys & Med Technol, NL-1081 HV Amsterdam, Netherlands
[3] Vrije Univ Amsterdam Med Ctr, Inst Cardiovasc Res, NL-1081 HV Amsterdam, Netherlands
[4] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[5] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
magnetic resonance myocardial perfusion imaging; absolute quantification; dual bolus; coronary artery disease; diagnostic value; POSITRON-EMISSION-TOMOGRAPHY; BLOOD-FLOW; HEALTHY HUMANS; RESERVE; QUANTIFICATION; MRI; DECONVOLUTION; ANGIOGRAPHY; HEART; MODEL;
D O I
10.1002/jmri.22231
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the incremental diagnostic value of dual-bolus over single-contrast-bolus first pass magnetic resonance myocardial perfusion imaging (MR-MPI) for detection of significant coronary artery disease (CAD). Materials and Methods: Patients (n = 49) with suspected CAD underwent first pass adenosine stress and rest MR-MPI and invasive coronary angiography (CA). Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) was injected with a prebolus (1 mL) and a large bolus (0.1 mmol/kg). For the single-bolus technique, the arterial input function (AIF) was obtained from the large-contrast bolus. For the dual-bolus technique, the AIF was reconstructed from the prebolus. Absolute myocardial perfusion was calculated by Fermi-model constrained deconvolution. Receiver operating characteristic (ROC) analysis was used to investigate diagnostic accuracy of MR myocardial perfusion imaging for detection of significant CAD on CA at vessel-based analysis. Results: The area under the curve (AUC) of the minimal stress perfusion value for the detection of significant CAD using the single-bolus and dual-bolus technique was 0.85 +/- 0.04 (95% confidence interval [CI], 0.77-0.93) and 0.77 +/- 0.05 (95% CI, 0.67-0.86), respectively. Conclusion: In this study the dual-bolus technique had no incremental diagnostic value over single-bolus technique for detection of significant CAD with the used contrast concentrations.
引用
收藏
页码:88 / 93
页数:6
相关论文
共 50 条
  • [31] Magnetic resonance imaging of regional myocardial perfusion in patients with single-vessel coronary artery disease:: Quantitative comparison with 201thallium-SPECT and coronary angiography
    Keijer, JT
    van Rossum, AC
    van Eenige, MJ
    Bax, JJ
    Visser, FC
    Teule, JJ
    Visser, CA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (06) : 607 - 615
  • [32] Quantitative myocardial perfusion assessment with magnetic resonance imaging in patients with coronary artery disease: clinical application
    Gramovitch, VV
    Sinitsyn, VE
    Gordin, MP
    Stukalova, OV
    Ustuzhanin, DV
    Ternovoy, SK
    EUROPEAN HEART JOURNAL, 2004, 25 : 43 - 43
  • [33] Qualitative evaluation of magnetic resonance myocardial perfusion for the detection of coronary artery stenosis
    Al-Saadi, N
    Wassmuth, R
    Friedrich, MG
    CIRCULATION, 2003, 108 (17) : 402 - 402
  • [34] Quantitative myocardial perfusion magnetic resonance imaging: the impact of pulsatile flow on contrast agent bolus dispersion
    Graafen, Dirk
    Hamer, Julia
    Weber, Stefan
    Schreiber, Laura M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (16): : 5167 - 5185
  • [35] Magnetic resonance perfusion measurements for the noninvasive detection of coronary artery disease
    Nagel, E
    Klein, C
    Paetsch, I
    Hettwer, S
    Schnackenburg, B
    Wegscheider, K
    Fleck, E
    CIRCULATION, 2003, 108 (04) : 432 - 437
  • [36] Letter regarding Bettencourt et al. "Cardiac magnetic resonance myocardial perfusion imaging for detection of functionally significant obstructive coronary artery disease: A prospective study"
    Ma, Heng
    Wang, Yong
    Wen, Zhaoying
    Liu, Ying
    Liu, Jing
    Yang, Jun
    Wang, Bin
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (01) : 553 - 553
  • [37] Validation of Dynamic 3-Dimensional Whole Heart Magnetic Resonance Myocardial Perfusion Imaging Against Fractional Flow Reserve for the Detection of Significant Coronary Artery Disease
    Jogiya, Roy
    Kozerke, Sebastian
    Morton, Geraint
    De Silva, Kalpa
    Redwood, Simon
    Perera, Divaka
    Nagel, Eike
    Plein, Sven
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (08) : 756 - 765
  • [38] Evidence for myocardial CT perfusion imaging in the diagnosis of hemodynamically significant coronary artery disease
    Sun, Zhonghua
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2015, 5 (01) : 58 - 62
  • [39] Comparison of adenosine infusion and adenosine bolus in myocardial contrast echocardiography (Optison) for detection of coronary artery disease using nuclear imaging as the independent standard
    Nesser, HJ
    Yao, J
    Tkalec, W
    Ebner, C
    Steringer-Mascherbauer, R
    Ng, C
    Markl, B
    Morcerf, F
    Pandian, N
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 414A - 414A
  • [40] Disappearance of myocardial perfusion defects on prone SPECT imaging: Comparison with cardiac magnetic resonance imaging in patients without established coronary artery disease
    Hedén B.
    Persson E.
    Carlsson M.
    Pahlm O.
    Arheden H.
    BMC Medical Imaging, 9 (1)