Measurement of ultrafine particle size distributions from coal-, oil-, and gas-fired stationary combustion sources

被引:88
|
作者
Chang, MCO
Chow, JC
Watson, JG
Hopke, PK
Yi, SM
England, GC
机构
[1] Desert Res Inst, Reno, NV 89512 USA
[2] Clarkson Univ, Potsdam, NY USA
[3] Seoul Natl Univ, Seoul 151, South Korea
[4] GE Energy & Environm Res Corp, Irvine, CA USA
来源
关键词
D O I
10.1080/10473289.2004.10471010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Currently, we have limited knowledge of the physical and chemical properties of emitted primary combustion aerosols and the changes in those properties caused by nucleation, condensation growth of volatile species, and particle coagulations under dilution and cooling in the ambient air. A dilution chamber was deployed to sample exhaust from a pilot-scale furnace burning various fuels at a nominal heat input rate of 160 kW/h(-1) and 3% excess oxygen. The formation mechanisms of particles smaller than 420 nm in electrical mobility diameter were experimentally investigated by measurement with a Scanning Mobility Particle Sizer (SMPS) as a function of aging times, dilution air ratios, combustion exhaust temperatures, and fuel types. Particle formation in the dilution process is a complex mixture of nucleation, coagulation, and condensational growth, depending on the concentrations of available condensable species and solid or liquid particles (such as soot, ash) in combustion exhausts. The measured particle size distributions in number concentrations measured show peaks of particle number concentrations for medium sulfur bituminous coal, No. 6 fuel oil, and natural gas at 40-50 nm, 70-100 nm, and 15-25 nm, respectively. For No. 6 fuel oil and coal, the particle number concentration is constant in the range of a dilution air ratio of 50, but the number decreases as the dilution air ratio decreases to 10. However, for natural gas, the particle number concentration is higher at a dilution air ratio of 10 and decreases at dilution air ratios of 20-50. At a dilution air ratio of 10, severe particle coagulation occurs in a relatively short time. Samples taken at different combustion exhaust temperatures for these fuel types show higher particle number concentrations at 645 K than at 450 K. As the aging time of particles increases, the particles increase in size and the number concentrations decrease. The largest gradient of particle number distribution occurs within the first 10 sec after dilution but shows only minor differences between 10 and 80 sec. The lifetimes of the ultrafine particles are relatively short, with a scale on the order of a few seconds. Results from this study suggest that an aging time of 10 sec and a dilution air ratio of 20 are sufficient to obtain representative primary particle emission samples from stationary combustion sources.
引用
收藏
页码:1494 / 1505
页数:12
相关论文
共 23 条
  • [1] Proposal for the Conversion of Oil- or Gas-fired Water Tube Boilers to Coal Firing.
    Wieser, Rudolf
    Fernwarme international, 1982, 11 (01): : 28 - 30
  • [2] Thermoneutral tri-reforming of flue gases from coal- and gas-fired power stations
    Halmann, M
    Steinfeld, A
    CATALYSIS TODAY, 2006, 115 (1-4) : 170 - 178
  • [3] Methanol, hydrogen, or ammonia production by tri-reforming of flue gases from coal- and gas-fired power stations
    Halmann, M
    Steinfeld, A
    Energy-Efficient, Cost-Effective and Environmentally-Sustainable Systems and Processes, Vols 1-3, 2004, : 1117 - 1128
  • [4] Particle size distributions of ultrafine combustion aerosols generated from household fuels
    Tiwari, Mahesh
    Sahu, Sanjay Kumar
    Bhangare, Rahul Chindhu
    Yousaf, Ajmal
    Pandit, Gauri Girish
    ATMOSPHERIC POLLUTION RESEARCH, 2014, 5 (01) : 145 - 150
  • [5] Comparison of particle size distributions and elemental partitioning from the combustion of pulverized coal and residual fuel oil
    Linak, WP
    Miller, CA
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (08) : 1532 - 1544
  • [6] Comparison of particle size distributions and elemental partitioning from the combustion of pulverized coal and residual fuel oil
    Linak, William P.
    Miller, C. Andrew
    Wendt, Jost O.L.
    Journal of the Air and Waste Management Association, 2000, 50 (08): : 1532 - 1544
  • [7] Parametric Process Design and Economic Analysis of Post-Combustion CO2 Capture and Compression for Coal- and Natural Gas-Fired Power Plants
    Adu, Emmanuel
    Zhang, Y. D.
    Liu, Dehua
    Tontiwachwuthikul, Paitoon
    ENERGIES, 2020, 13 (10)
  • [8] Hazardous air pollutant emissions from gas-fired combustion sources: emissions and the effects of design and fuel type
    England, GC
    McGrath, TP
    Gilmer, L
    Seebold, JG
    Lev-On, M
    Hunt, T
    CHEMOSPHERE, 2001, 42 (5-7) : 745 - 764
  • [9] Particle-size distributions and heavy metal partitioning in emission gas from different coal-fired power plants
    Yoo, JI
    Seo, YC
    Shinagawa, T
    ENVIRONMENTAL ENGINEERING SCIENCE, 2005, 22 (02) : 272 - 279
  • [10] Size and chemical characteristics of fine particulate emissions from oil- and coal-fired pilot scale boilers.
    Lee, SW
    He, I
    Herage, T
    Young, B
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U573 - U573