Parametric Process Design and Economic Analysis of Post-Combustion CO2 Capture and Compression for Coal- and Natural Gas-Fired Power Plants

被引:21
|
作者
Adu, Emmanuel [1 ,2 ]
Zhang, Y. D. [1 ,3 ]
Liu, Dehua [1 ]
Tontiwachwuthikul, Paitoon [4 ]
机构
[1] Yangtze Univ, Sch Petr Engn, Dept Oil & Gas Storage & Transportat Engn, Wuhan 430100, Peoples R China
[2] Kumasi Tech Univ, Fac Engn & Technol, Mech Engn Dept, POB 854, Kumasi, Ghana
[3] Natl Res Council Canada, Measurement Sci & Stand, Bldg M-9,1200 Montreal Rd, Ottawa, ON K1A OR6, Canada
[4] Univ Regina, Fac Engn & Appl Sci, Clean Energy Technol Res Inst CETRI, 3737 Wascana Pkwy, Regina, SK S4S0A2, Canada
基金
中国国家自然科学基金;
关键词
post-combustion; carbon capture and storage; coal-fired power plants; NGCC; energy; economic analysis; LOCAL COMPOSITION MODEL; CARBON-DIOXIDE CAPTURE; EXCESS GIBBS ENERGY; TECHNOECONOMIC ANALYSIS; PILOT-PLANT; PERFORMANCE; STORAGE; TECHNOLOGY; PROGRESS; SOLVENT;
D O I
10.3390/en13102519
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
For the envisaged large number of commercial-scale carbon capture and storage (CCS) projects that are to be implemented in the near future, a number of issues still need to be resolved, the most prominent being the large capital and operational costs incurred for the CO2 capture and compression process. An economic assessment of the capture and compression system based on optimal design data is important for CCS deployment. In this paper, the parametric process design approach is used to optimally design coal and natural gas monoethanolamine (MEA)-based post-combustion CO2 absorption-desorption capture (PCC) and compression plants that can be integrated into large-scale 550 MW coal-fired and 555 MW natural gas combined cycle (NGCC) power plants, respectively, for capturing CO2 from their flue gases. The study then comparatively assesses the energy performance and economic viabilities of both plants to ascertain their operational feasibilities and relative costs. The parametric processes are presented and discussed. The results indicate that, at 90% CO2 capture efficiency, for the coal PCC plant, with 13.5 mol.% CO2 in the inlet flue gas, at an optimum liquid/gas ratio of 2.87 kg/kg and CO2 lean loading of 0.2082 mol CO2/mol MEA, the CO2 avoidance cost is about $72/tCO(2), and, for the NGCC PCC plant, with 4.04 mol.% CO2 in the inlet flue gas, at an optimum liquid/gas ratio of 0.98 kg/kg and CO2 lean loading of 0.2307 mol CO2/mol MEA, the CO2 avoidance cost is about $94/tCO(2).
引用
收藏
页数:28
相关论文
共 50 条
  • [1] Preliminary Performance and Cost Evaluation of Four Alternative Technologies for Post-Combustion CO2 Capture in Natural Gas-Fired Power Plants
    Gatti, Manuele
    Martelli, Emanuele
    Di Bona, Daniele
    Gabba, Marco
    Scaccabarozzi, Roberto
    Spinelli, Maurizio
    Vigano, Federico
    Consonni, Stefano
    ENERGIES, 2020, 13 (03)
  • [3] Dynamic modelling and simulation of a post-combustion CO2 capture process for coal-fired power plants
    Jianlin Li
    Ti Wang
    Pei Liu
    Zheng Li
    Frontiers of Chemical Science and Engineering, 2022, 16 : 198 - 209
  • [4] Dynamic modelling and simulation of a post-combustion CO2 capture process for coal-fired power plants
    Li, Jianlin
    Wang, Ti
    Liu, Pei
    Li, Zheng
    FRONTIERS OF CHEMICAL SCIENCE AND ENGINEERING, 2022, 16 (02) : 198 - 209
  • [5] Dynamic modelling and simulation of a post-combustion CO2 capture process for coal-fired power plants
    Li Jianlin
    Wang Ti
    Liu Pei
    Li Zheng
    Frontiers of Chemical Science and Engineering, 2022, 16 (02) : 198 - 209
  • [6] Thermodynamic analysis on post-combustion CO2 capture of natural-gas-fired power plant
    Amrollahi, Zeinab
    Ertesvag, Ivar S.
    Bolland, Olav
    INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2011, 5 (03) : 422 - 426
  • [7] Systems Analysis of Ionic Liquids for Post-combustion CO2 Capture at Coal-fired Power Plants
    Zhai, Haibo
    Rubin, Edward S.
    12TH INTERNATIONAL CONFERENCE ON GREENHOUSE GAS CONTROL TECHNOLOGIES, GHGT-12, 2014, 63 : 1321 - 1328
  • [8] Performance and Economic Analysis of 500 MWe Coal-Fired Power Plant with Post-Combustion CO2 Capture Process
    Lee, Ji Hyun
    Kim, Jun-Han
    Lee, In Young
    Jang, Kyung Ryoung
    Shim, Jae-Goo
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2011, 49 (02): : 244 - 249
  • [9] Analysis of CO2 post-combustion capture in coal-fired power plants integrated with renewable energies
    Carapellucci, Roberto
    Giordano, Lorena
    Vaccarelli, Maura
    70TH CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, ATI2015, 2015, 82 : 350 - 357
  • [10] Performance and Economic Analysis of Domestic Supercritical Coal-Fired Power Plant with Post-Combustion CO2 Capture Process
    Lee, Ji-Hyun
    Kwak, No-Sang
    Lee, In-Young
    Jang, Kyung-Ryoung
    Shim, Jae-Goo
    KOREAN CHEMICAL ENGINEERING RESEARCH, 2012, 50 (02): : 365 - 370