Glenohumeral Contact Kinematics in Patients After Total Shoulder Arthroplasty

被引:30
|
作者
Massimini, Daniel F. [1 ]
Li, Guoan [1 ]
Warner, Jon P. [1 ]
机构
[1] Massachusetts Gen Hosp, Bioengn Lab, Boston, MA 02114 USA
来源
关键词
RETRIEVED GLENOID COMPONENTS; ARTICULAR-CARTILAGE CONTACT; CONSTANT SCORE; HUMERAL HEAD; REPLACEMENT ARTHROPLASTY; SCAPULOHUMERAL RHYTHM; SURGICAL TECHNIQUE; PROSTHETIC DESIGN; JOINT KINEMATICS; REACTION FORCES;
D O I
10.2106/JBJS.H.01610
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Knowledge of in vivo glenohumeral joint contact mechanics after total shoulder arthroplasty may provide insight for the improvement of patient function, implant longevity, and surgical technique. The objective of this study was to determine the in vivo glenohumeral joint contact locations in patients after total shoulder arthroplasty. We hypothesized that the glenohumeral joint articular contact would be centered on the glenoid surface because of the ball-in-socket geometric features of the implants. Methods: Dual-plane fluoroscopic images and computer-aided design models were used to quantify patient-specific glenohumeral articular contact in thirteen shoulders following total shoulder arthroplasty. The reconstructed shoulder was imaged at arm positions of 0 degrees, 45 degrees, and 90 degrees of abduction (in the coronal plane) and neutral rotation and at 90 degrees of abduction with maximum internal and external rotation. The patients were individually investigated, and their glenohumeral joint contact centroids were reported with use of contact frequency. Results: In all positions, the glenohumeral joint contact centroids were not found at the center of the glenoid surface but at an average distance (and standard deviation) of 11.0 +/- 4.3 mm from the glenoid center. Forty (62%) of the sixty-five total contact occurrences were found on the superior-posterior quadrant of the glenoid surface. The position of 0 degrees of abduction in neutral rotation exhibited the greatest variation of quadrant contact location; however, no contact was found on the superior-anterior quadrant of the glenoid surface in this position. Conclusions: In vivo, glenohumeral joint contact after total shoulder arthroplasty is not centered on the glenoid surface, suggesting that kinematics after shoulder arthroplasty may not be governed by ball-in-socket mechanics as traditionally thought. Although contact locations as a function of arm position vary among patients, the superior-posterior quadrant seems to experience the most articular contact in the shoulder positions tested.
引用
收藏
页码:916 / 926
页数:11
相关论文
共 50 条
  • [21] Glenohumeral Arthrodesis After Failed Prosthetic Shoulder Arthroplasty
    Scalise, Jason J.
    Iannotti, Joseph P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A : 30 - 37
  • [22] Outcome of Revision Shoulder Arthroplasty After Resurfacing Hemiarthroplasty in Patients with Glenohumeral Osteoarthritis
    Rasmussen, Jeppe V.
    Olsen, Bo S.
    Al-Hamdani, Ali
    Brorson, Stig
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2016, 98 (19): : 1631 - 1637
  • [23] Risk factors for failing to achieve improvement after anatomic total shoulder arthroplasty for glenohumeral osteoarthritis
    Mahony, Gregory T.
    Werner, Brian C.
    Chang, Brenda
    Grawe, Brian M.
    Taylor, Samuel A.
    Craig, Edward V.
    Warren, Russell F.
    Dines, David M.
    Gulotta, Lawrence V.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (06) : 968 - 975
  • [24] The effects of prosthetic humeral head shape on glenohumeral joint kinematics during humeral axial rotation in total shoulder arthroplasty
    Jun, Bong Jae
    Lee, Thay Q.
    McGarry, Michelle H.
    Quigley, Ryan J.
    Shin, Sang Jin
    Iannotti, Joseph P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (07) : 1084 - 1093
  • [25] Kinematics and EMG activity in Reverse Total Shoulder Arthroplasty
    Smith, Ryan A.
    Woolley, Katherine
    Mazzocca, Augustus
    Feinn, Richard
    Cote, Mark
    Gomlinski, Gregg
    Garbalosa, Juan
    Myrick, Karen M.
    JOURNAL OF ORTHOPAEDICS, 2020, 22 : 165 - 169
  • [26] Current Role of Reverse Total Shoulder Arthroplasty in the Management of Glenohumeral Osteoarthritis
    Hays, Claire
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2024, 55 (04) : 489 - 502
  • [27] Radiographic performance depends on the radial glenohumeral mismatch in total shoulder arthroplasty
    Hasler, Anita
    Meyer, Dominik C.
    Tondelli, Timo
    Dietrich, Tobias
    Gerber, Christian
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [28] Radiographic performance depends on the radial glenohumeral mismatch in total shoulder arthroplasty
    Anita Hasler
    Dominik C. Meyer
    Timo Tondelli
    Tobias Dietrich
    Christian Gerber
    BMC Musculoskeletal Disorders, 21
  • [29] Effects of Prosthetic Mismatch and Subscapularis Tear on Glenohumeral Contact Patterns in Total Shoulder Arthroplasty: A Numerical Musculoskeletal Analysis
    Sins, Lauranne
    Tetreault, Patrice
    Nuno, Natalia
    Hagemeister, Nicola
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (12):
  • [30] Glenohumeral Arthritis: Current Indications for Hemiarthroplasty Versus Total Shoulder Arthroplasty
    Throckmorton, Thomas W.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2016, 17 (01): : 25 - 26