High voltage AC-DC difference measurements underhumidity step changes

被引:2
|
作者
Liu, LX [1 ]
Chua, SW [1 ]
Ang, CK [1 ]
机构
[1] Singapore Stand Product & Innovat Board SPRING Si, Natl Meteorol Ctr, Singapore 118221, Singapore
关键词
Calculations - Differential equations - Electric impedance - Frequencies - Mathematical models - Resistors - Standards - Transfer functions - Voltage measurement;
D O I
10.1049/ip-smt:20020745
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Preliminary results of AC-DC difference measurements using a thermal voltage converter with range resistor. under humidity change conditions are reported. The AC-DC difference measurement results, from a Holt-11 thermal converter at 100 and 200 V and frequency range from 40Hz to 100kHz, have shown that a first-order differential equation can be used to model this phenomenon. The humidity coefficients for the model are found to be frequency dependent and the time constants are related to the changes of humidity.
引用
收藏
页码:317 / 319
页数:3
相关论文
共 50 条
  • [21] Calorimetric thermal voltage converter as a wideband calculable standard of ac-dc difference
    Filipski, PS
    Clark, RF
    Paulusse, DC
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 167 - 168
  • [22] AC-DC voltage transfer difference due to Seebeck effect in thermal converters
    Takahashi, K
    Sasaki, H
    Inglis, BD
    Klonz, M
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 169 - 170
  • [23] Investigations of time stability of the ac-dc transfer difference of thermal voltage converters
    Grzenik, Michal
    Kampik, Marian
    PRZEGLAD ELEKTROTECHNICZNY, 2022, 98 (12): : 84 - 87
  • [24] Evaluation of LF AC-DC difference of coaxially mounted thermal voltage converter
    Filipski, PS
    Clark, RF
    Paulusse, DC
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 720 - 725
  • [25] Calorimetric thermal voltage converter as a wideband calculable standard of AC-DC difference
    Filipski, PS
    Clark, RF
    Paulusse, DC
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 387 - 390
  • [26] AC DC DIFFERENCE MEASUREMENTS ON THERMAL VOLTAGE CONVERTERS AT NRC
    MATSUMURA, T
    CLARK, RF
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1987, 36 (02) : 333 - 336
  • [27] Measurement system for the voltage dependence of high voltage ac-dc thermal converters
    Pogliano, U
    Bosco, GC
    D'Elia, V
    1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 377 - 378
  • [28] Automated comparator for accurate AC-DC difference measurements at the BNM-LCIE
    Poletaeff, A
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 412 - 414
  • [29] AC-DC Transfer Difference Measurements using a Frequency Output Thermal Converter
    Geronymo, G. M.
    Ihlenfeld, W. G. K.
    Landim, R. P.
    9TH BRAZILIAN CONGRESS ON METROLOGY (METROLOGIA 2017), 2018, 975
  • [30] DUAL-CHANNEL AUTOMATED COMPARATOR FOR AC-DC DIFFERENCE MEASUREMENTS.
    Williams, Earl S.
    Kinard, Joseph R.
    IEEE Transactions on Instrumentation and Measurement, 1984, IM-34 (02)