13N-Ammonia myocardial blood flow quantitation in patient with aneurismal coronary artery disease

被引:0
|
作者
Plata-Corona, Juan Carlos [1 ]
Carvajal-Juarez, Isabel [2 ,3 ]
Espinola-Zavaleta, Nilda [2 ,4 ]
de los Santos, Felix Damas [5 ]
Rivera-Bravo, Belen [6 ]
Alexanderson-Rosas, Erick [2 ,6 ,7 ]
机构
[1] Natl Inst Cardiol Ignacio Chavez, Clin Cardiol Dept, Mexico City, DF, Mexico
[2] Natl Inst Cardiol Ignacio Chavez, Nucl Cardiol Dept, Uan Badiano 1,Colonia Secc 16, Mexico City 14080, DF, Mexico
[3] CMNSXXI, Cardiol Hosp, UMAE, Nucl Med Dept, Mexico City, DF, Mexico
[4] ABC Med Ctr, Echocardiog Dept, Mexico City, DF, Mexico
[5] Natl Inst Cardiol Ignacio Chavez, Hemodynam Dept, Mexico City, DF, Mexico
[6] Autonomous Natl Univ Mexico UNAM, Fac Med, PET CT Unit, Mexico City, DF, Mexico
[7] Autonomous Natl Univ Mexico UNAM, Fac Med, Dept Physiol, Mexico City, DF, Mexico
关键词
Coronary artery aneurysm; coronary artery ectasia; positron emission tomography; coronary blood flow; coronary flow reserve; ECTASIA; PREVALENCE; PERFUSION; HISTORY;
D O I
10.1007/s12350-021-02642-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aneurysmal coronary artery disease includes coronary artery aneurysms and ectasia; this condition has been associated with poor long-term outcomes. Few studies have explored myocardial blood flow N-13-ammonia PET/CT MPI added value. We present a 45-year-old man who came to the emergency department with chest pain. After a physical examination and laboratory studies, he was diagnosed with very high-risk unstable angina and referred to the catheterization laboratory. Coronary angiography showed the culprit lesion in the LCx and was treated by angioplasty and stent. LAD was found with coronary artery ectasia (TIMI 2 flow grade) and the RCA with aneurysmal disease in the proximal and middle segments (TIMI 3 flow grade). Medical treatment was decided for these findings and the patient was discharged. Two weeks later, we performed a N-13-ammonia PET/CT MPI founding apical, inferior, and inferoseptal severe ischemia, and reduced hyperemic coronary blood flow and coronary flow reserve in the RCA territory. Flow was normal in the LAD territory. Although coronary angiography remains the gold standard for evaluating these coronary abnormalities, it does not show the physiological compromise. Therefore N-13-ammonia PET/CT MPI should be performed as a complementary noninvasive imaging approach.
引用
收藏
页码:1826 / 1831
页数:6
相关论文
共 50 条
  • [31] Human 13N-ammonia PET studies: the importance of measuring 13N-ammonia metabolites in blood
    Susanne Keiding
    Michael Sørensen
    Ole Lajord Munk
    Dirk Bender
    Metabolic Brain Disease, 2010, 25 : 49 - 56
  • [32] Diagnostic performance of quantitative 13N-ammonia PET/CT measures of coronary flow reserve and myocardial blood flow for the assessment of functional significance of coronary stenoses
    Shavman, M. G.
    Bockeria, L. A.
    Aslanidis, I. P.
    Shurupova, I. V.
    Ekaeva, I. V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S283 - S284
  • [33] Oestrogen increases myocardial blood flow in men:: assessment by 13N-ammonia positron emission tomography
    Yoshioka, J
    Hasegawa, S
    Node, K
    Nakatani, D
    Kitakaze, M
    Hori, M
    Nishimura, T
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (06) : 557 - 562
  • [34] Role of quantitative myocardial blood flow and 13N-ammonia washout for viability assessment in ischemic cardiomyopathy
    Benz, Dominik C.
    Ferro, Paola
    Safa, Nico
    Messerli, Michael
    von Felten, Elia
    Huang, Wenjie
    Patriki, Dimitri
    Giannopoulos, Andreas A.
    Fuchs, Tobias A.
    Grani, Christoph
    Gebhard, Catherine
    Pazhenkottil, Aju P.
    Kaufmann, Philipp A.
    Buechel, Ronny R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (01) : 263 - 273
  • [35] Quantifying the normal range of myocardial blood flow with 13N-ammonia PET and tracer kinetic modeling
    Renaud, Jennifer M.
    Lortie, Mireille
    Wassenaar, Richard W.
    DaSilva, Jean
    Beanlands, Robert S.
    deKemp, Robert A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1686 - 1690
  • [36] HUMAN 13N-AMMONIA PET STUDIES: THE IMPORTANCE OF MEASURING 13N-AMMONIA METABOLITES IN BLOOD
    Sorensen, M.
    Keiding, S.
    Munk, O. L.
    Bender, D.
    JOURNAL OF HEPATOLOGY, 2010, 52 : S216 - S216
  • [37] Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET
    Alessio, Adam M.
    Bassingthwaighte, James B.
    Glenny, Robb
    Caldwell, James H.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (01) : 64 - 75
  • [38] Does global value of myocardial flow reserve using 13N-ammonia positron emission tomography independently predict identification of multivessel coronary artery disease
    Shakhova, A.
    Golukhova, E.
    Aslanidis, I.
    Shurupova, I.
    Surkova, N.
    Rumyantseva, M.
    Ekaeva, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S201 - S202
  • [39] Effect of temporal sampling protocols on myocardial blood flow quantification using 13N-ammonia PET
    Hu, Yingqi
    Wang, Ruonan
    Zhang, Chuxin
    Li, Yuanyuan
    Wang, Yanhui
    Diao, Xin
    Zhang, Jun
    Jia, Yanni
    Li, Sijin
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [40] Validation of an axially distributed model for quantification of myocardial blood flow using 13N-ammonia PET
    Adam M. Alessio
    James B. Bassingthwaighte
    Robb Glenny
    James H. Caldwell
    Journal of Nuclear Cardiology, 2013, 20 : 64 - 75