An investigation of ventilation control strategies for louver windows in different climate zones

被引:5
|
作者
Scheuring, Leonie [1 ]
Weller, Bernhard [1 ]
机构
[1] Tech Univ Dresden, Inst Bldg Construct, August Bebel Str 30, D-01219 Dresden, Germany
关键词
Indoor air quality; natural ventilation; control strategies; louver window; energy performance; NATURAL VENTILATION; COOLING STRATEGIES;
D O I
10.1080/14733315.2020.1777018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Guaranteeing high indoor air quality and high degree of usersatisfaction at the same time is one of the challenges when improving the energy efficiency, namely the energy consumption, of a building. Current non-residential buildings mainly use mechanical ventilation systems to ensure high air quality. Natural ventilation can be an alternative regarding to lower maintenance costs and the psychological feeling of fresh air. Present natural ventilated buildings pose the risk of higher energy demand and less indoor air quality due to user's behaviour. Controlled natural ventilation based on indoor CO2 concentration and room air temperature is needed. However, the energy efficiency of a control strategy highly depends on climate zone and control parameters. This paper aims to explore the impact of different control strategies on the energy efficiency of an operable louver window. The analyses are done for yearly results and then for each month individual to clarify the effect of monthly varying control strategies. For the analysis EnergyPlus as a building energy simulation tool and for the natural ventilation in specific the EnergyPlus Design Flow Rate method is used. In the simulation four window opening strategies based on CO2 concentration and one simple intake/exhaust mechanical ventilation system were tested in Mediterranean, subtropical and moderate climate zone. The highest impact on energy efficiency and thermal comfort was seen at the cold months in the moderate climate. Long window opening strategies cannot be implemented because of a high thermal discomfort. In the hot months in the Mediterranean and subtropical climate an impact of ventilation strategies are seen as well. Only at moderate conditions no major differences in the natural ventilation strategies were observed. When comparing the natural ventilation conditions to mechanical ventilation major differences were found. In almost all climate conditions natural ventilation outperformed the mechanical ventilation. Only in winter months in the moderate climate mechanical ventilation outperforms natural ventilation.
引用
收藏
页码:226 / 235
页数:10
相关论文
共 50 条
  • [1] Variable air volume ventilation control strategies analysed in six climate zones
    Ke, YP
    Mumma, SA
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1999, 23 (05) : 371 - 387
  • [2] Thermal and economic windows design for different climate zones
    Jaber, Samar
    Ajib, Salman
    [J]. ENERGY AND BUILDINGS, 2011, 43 (11) : 3208 - 3215
  • [3] Evaluation on energy efficiency of windows in different climate zones of China
    Fang, Shanshan
    Chen, Youming
    [J]. BUILDING SIMULATION 2007, VOLS 1-3, PROCEEDINGS, 2007, : 1638 - 1644
  • [4] Evaluation of Building Retrofit Strategies in Different Climate Zones
    Yao, Runming
    Han, Shiyu
    Li, Xinyi
    Shahrestani, Mehdi
    Li, Baizhan
    [J]. ASHRAE TRANSACTIONS, VOL 122, PT 1, 2016, 122 : 289 - 299
  • [5] Numerical evaluation of louver configuration and ventilation strategies for the windcatcher system
    Liu, Shichao
    Mak, C. M.
    Niu, JianLei
    [J]. BUILDING AND ENVIRONMENT, 2011, 46 (08) : 1600 - 1616
  • [6] Hybrid zones: windows on climate change
    Taylor, Scott A.
    Larson, Erica L.
    Harrison, Richard G.
    [J]. TRENDS IN ECOLOGY & EVOLUTION, 2015, 30 (07) : 398 - 406
  • [7] Ventilation behavior in residential buildings with mechanical ventilation systems across different climate zones in China
    Lai, Dayi
    Qi, Yue
    Liu, Junjie
    Dai, Xilei
    Zhao, Lei
    [J]. BUILDING AND ENVIRONMENT, 2018, 143 : 679 - 690
  • [8] The influence of building material, windows and insulators on energy saving in different climate zones in Iran
    P. Gohari
    [J]. International Journal of Energy and Water Resources, 2019, 3 (4) : 283 - 289
  • [9] Passive Design Strategies for Residential Buildings in Different Spanish Climate Zones
    Fernandez-Antolin, Maria-Mar
    Manuel del Rio, Jose
    Costanzo, Vincenzo
    Nocera, Francesco
    Gonzalez-Lezcano, Roberto-Alonso
    [J]. SUSTAINABILITY, 2019, 11 (18)
  • [10] Application potential analysis of different control strategies for radiant floor cooling systems in office buildings in different climate zones of China
    Cui, Mengying
    Liu, Jiying
    Kim, Moon Keun
    Wu, Xiaozhou
    [J]. ENERGY AND BUILDINGS, 2023, 282