Development of a fast Monte Carlo dose calculation system for online adaptive radiation therapy quality assurance

被引:20
|
作者
Wang, Yuhe [1 ]
Mazur, Thomas R. [1 ]
Park, Justin C. [1 ]
Yang, Deshan [1 ]
Mutic, Sasa [1 ]
Li, H. Harold [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, St Louis, MO 63110 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 12期
关键词
GPU; Monte Carlo; variance reduction; MRI guided radiation therapy; adaptive radiation therapy; RADIOTHERAPY; PHOTON; GEANT4; IMPLEMENTATION; SIMULATION; TRANSPORT; EGSNRC; CODE;
D O I
10.1088/1361-6560/aa6e38
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Online adaptive radiation therapy (ART) based on real-time magnetic resonance imaging represents a paradigm-changing treatment scheme. However, conventional quality assurance (QA) methods based on phantom measurements are not feasible with the patient on the treatment couch. The purpose of this work is to develop a fast Monte Carlo system for validating online re-optimized tri-Co-60 IMRT adaptive plans with both high accuracy and speed. The Monte Carlo system is based on dose planning method (DPM) code with further simplification of electron transport and consideration of external magnetic fields. A vendor-provided head model was incorporated into the code. Both GPU acceleration and variance reduction were implemented. Additionally, to facilitate real-time decision support, a C++ GUI was developed for visualizing 3D dose distributions and performing various analyses in an online adaptive setting. A thoroughly validated Monte Carlo code (gPENELOPE) was used to benchmark the new system, named GPU-accelerated DPM with variance reduction (gDPMvr). The comparison using 15 clinical IMRT plans demonstrated that gDPMvr typically runs 43 times faster with only 0.5% loss in accuracy. Moreover, gDPMvr reached 1% local dose uncertainty within 2.3 min on average, and thus is well-suited for ART QA.
引用
收藏
页码:4970 / 4990
页数:21
相关论文
共 50 条
  • [41] Development of a flattening filter free multiple source model for use as an independent, Monte Carlo, dose calculation, quality assurance tool for clinical trials
    Faught, Austin M.
    Davidson, Scott. E.
    Popple, Richard
    Kry, Stephen F.
    Etzel, Carol
    Ibbott, Geoffrey S.
    Followill, David S.
    MEDICAL PHYSICS, 2017, 44 (09) : 4952 - 4960
  • [42] Numerical system utilising a Monte Carlo calculation method for accurate dose assessment in radiation accidents
    Takahashi, F.
    Endo, A.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 595 - 599
  • [43] Calculation of radiation dose to the lens of the eye using Monte Carlo simulation
    Meriç, N
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (04) : 557 - 560
  • [44] MONTE-CARLO CALCULATION OF INTEGRAL RADIATION-DOSE IN XEROMAMMOGRAPHY
    DANCE, DR
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (01): : 25 - 37
  • [45] Monte Carlo Dose Verification and Quality Assurance for Multi-Target SRT
    Lin, T.
    Wang, L.
    Fan, J.
    Li, J.
    Ma, C.
    MEDICAL PHYSICS, 2008, 35 (06) : 2954 - +
  • [46] Toward Daily Dose Tracking for Adaptive Therapy: Feasibility Using Monte Carlo Dose Calculation on Corrected CBCT Images
    Lamba, N.
    Pittock, D.
    Ginsburg, S.
    Bonsall, H.
    Fung, W. W. K.
    Man, H. M. C.
    Kruzer, A.
    Nelson, A. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E732 - E733
  • [47] Monte Carlo based dose calculations for quality assurance in the electronic medical record
    Linton, N.
    Pencea, S.
    Krivosheev, O.
    Napolitano, M.
    Alber, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2470 - 2470
  • [48] Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance
    Ali, Imad
    Ahmad, Salahuddin
    MEDICAL DOSIMETRY, 2013, 38 (03) : 255 - 261
  • [49] PMC, a new fast Monte Carlo code for radiation therapy
    Jabbari, K.
    Seuntjens, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2482 - 2482
  • [50] Development and benchmarking of the first fast Monte Carlo engine for helium ion beam dose calculation: MonteRay
    Lysakovski, Peter
    Besuglow, Judith
    Kopp, Benedikt
    Mein, Stewart
    Tessonnier, Thomas
    Ferrari, Alfredo
    Haberer, Thomas
    Debus, Juergen
    Mairani, Andrea
    MEDICAL PHYSICS, 2023, 50 (04) : 2510 - 2524