High speed three-dimensional endoscopic OCT using MEMS technology

被引:1
|
作者
Chen, Zhongping [1 ,2 ]
Jung, Woonggyu [1 ,2 ]
Ahn, Yeh-Chan [1 ]
Sepehr, Ali [1 ,3 ]
Armstrong, William B. [3 ]
Brenner, Matt [1 ,4 ]
McCormick, Daniel T. [5 ,6 ]
Tien, Norman C. [7 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA USA
[3] Univ Calif Irvine, Dept Otolaryngol Head & Neck Surg, Irvine, CA USA
[4] Univ Calif Irvine, Dept Pulm Med, Irvine, CA USA
[5] Univ Calif Berkeley, Berkeley Sensor & Actuator Ctr, Berkeley, CA 94720 USA
[6] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[7] Case Western Reserve Univ, Dept Elect & Comp Engn, Cleveland, OH 44106 USA
来源
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
endoscopic optical coherence tomography (OCT); MEMS technology; 3D imaging;
D O I
10.1117/12.713950
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a three-dimensional (3-D) endoscopic optical coherence tomography (OCT) system using a dual axis scanning mirror. The MEMS device employed in this study utilized a 12 min mirror and exhibited x and y-axis resonant frequencies greater than 1 kHz. The developed probe was packaged and integrated with an OCT system which has a scan rate of 3-8 frames/s. Preliminary in vivo and in vitro 3-D OCT images of biological tissue, such as human finger, vocal cord, rabbit trachea, were visualized to verify the achieved performance of the device.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Three-dimensional endoscopic system
    Yoshida, T
    Inoue, H
    Kudo, SE
    GASTROINTESTINAL ENDOSCOPY, 2002, 55 (05) : AB108 - AB108
  • [22] MEMS three-dimensional scan mirror
    Shao, Y
    Dickensheets, DL
    MOEMS AND MINIATURIZED SYSTEMS IV, 2004, 5346 : 249 - 257
  • [23] MEMS three-dimensional scan mirror
    Shao, YH
    Dickensheets, DL
    MOEMS DISPLAY AND IMAGING SYSTEMS II, 2004, 5348 : 175 - 183
  • [24] Three-dimensional bonding technologies for MEMS
    Vaganov, V
    Belov, N
    't Hout, SI
    SMART SENSORS, ACTUATORS, AND MEMS, PTS 1 AND 2, 2003, 5116 : 890 - 900
  • [25] High speed test interface module using MEMS technology
    Kandalaft, Nabeeh
    Attaran, Ali
    Rashizadeh, Rashid
    MICROELECTRONICS RELIABILITY, 2015, 55 (02) : 374 - 382
  • [26] Three-dimensional optics for optical data storage and optical MEMs using two-photon technology
    Kawata, S
    18TH CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: OPTICS FOR THE NEXT MILLENNIUM, TECHNICAL DIGEST, 1999, 3749 : 442 - 443
  • [27] A Three-Dimensional Integrated Micro Calorimetric Flow Sensor in CMOS MEMS Technology
    Xu, Wei
    Wang, Bo
    Duan, Mingzheng
    Ahmed, Moaaz
    Bermak, Amine
    Lee, Yi-Kuen
    IEEE SENSORS LETTERS, 2019, 3 (02)
  • [28] Endoscopic transseptal transsphenoidal hypophysectomy with three-dimensional intraoperative localization technology
    Moses, RL
    Keane, WM
    Andrews, DW
    Goel, R
    Simeone, F
    LARYNGOSCOPE, 1999, 109 (03): : 509 - 512
  • [29] Rainbow three-dimensional camera: New concept of high-speed three-dimensional vision systems
    Geng, ZJ
    OPTICAL ENGINEERING, 1996, 35 (02) : 376 - 383
  • [30] Wide dynamic range high-speed three-dimensional quantitative OCT angiography with a hybrid-beam scan
    Park, Taejin
    Jang, Sun-Joo
    Han, Myounghee
    Ryu, Sukyoung
    Oh, Wang-Yuhl
    OPTICS LETTERS, 2018, 43 (10) : 2237 - 2240