High speed three-dimensional endoscopic OCT using MEMS technology

被引:1
|
作者
Chen, Zhongping [1 ,2 ]
Jung, Woonggyu [1 ,2 ]
Ahn, Yeh-Chan [1 ]
Sepehr, Ali [1 ,3 ]
Armstrong, William B. [3 ]
Brenner, Matt [1 ,4 ]
McCormick, Daniel T. [5 ,6 ]
Tien, Norman C. [7 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA USA
[3] Univ Calif Irvine, Dept Otolaryngol Head & Neck Surg, Irvine, CA USA
[4] Univ Calif Irvine, Dept Pulm Med, Irvine, CA USA
[5] Univ Calif Berkeley, Berkeley Sensor & Actuator Ctr, Berkeley, CA 94720 USA
[6] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[7] Case Western Reserve Univ, Dept Elect & Comp Engn, Cleveland, OH 44106 USA
来源
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
endoscopic optical coherence tomography (OCT); MEMS technology; 3D imaging;
D O I
10.1117/12.713950
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a three-dimensional (3-D) endoscopic optical coherence tomography (OCT) system using a dual axis scanning mirror. The MEMS device employed in this study utilized a 12 min mirror and exhibited x and y-axis resonant frequencies greater than 1 kHz. The developed probe was packaged and integrated with an OCT system which has a scan rate of 3-8 frames/s. Preliminary in vivo and in vitro 3-D OCT images of biological tissue, such as human finger, vocal cord, rabbit trachea, were visualized to verify the achieved performance of the device.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] High speed three-dimensional endoscopic OCT using MEMS technology
    Chen, Zhongping
    2007 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1-4, 2007, : 170 - 170
  • [2] Three-dimensional time and Fourier domain endoscopic OCT using 2 axis scanning MEMS mirror
    Jung, Woonggyu
    McCormick, Daniel T.
    Ahn, Yeh-Chan
    Zhang, Jun
    Tien, Norman C.
    Chen, Zhongping
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [3] Three-dimensional retinal imaging with high speed and high resolution OCT
    Werner, JS
    Zawadzki, RJ
    Zhao, M
    Izatt, JA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [4] Development of a High-Speed Endoscopic OCT System and Its Application to Three-Dimensional Intravascular Imaging in Vivo
    Cho, Han Saem
    Jang, Sun-Joo
    Oh, Wang-Yuhl
    KOREAN JOURNAL OF OPTICS AND PHOTONICS, 2014, 25 (02) : 67 - 71
  • [5] Intraretinal thickness mapping using three-dimensional, high-speed ultrahigh resolution OCT
    Srinivasan, VJ
    Wojtkowski, M
    Ko, TH
    Carvalho, MT
    Witkin, AJ
    Schuman, JS
    Duker, JS
    Fujimoto, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [6] THREE-DIMENSIONAL MICROBATTERIES FOR MEMS/NEMS TECHNOLOGY
    Dunn, Bruce
    Kim, Chang-Jin
    Tolbert, Sarah
    MEMS 2010: 23RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2010, : 164 - 167
  • [7] Automatic three-dimensional segmentation of endoscopic airway OCT images
    Qi, Li
    Zheng, Kaibin
    Li, Xipan
    Feng, Qianjin
    Chen, Zhongping
    Chen, Wufan
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (02): : 642 - 656
  • [8] Microfabrication technology of three-dimensional microdevices and their MEMS applications
    Li, JF
    JOURNAL OF INORGANIC MATERIALS, 2002, 17 (04) : 657 - 664
  • [9] Endoscopic OCT using MEMS probes
    Zhang, J., 2005, Laurin Publishing Co. Inc. (12):
  • [10] The research on OCT deep cavity three-dimensional morphology of application of endoscopic
    Ding, Hongchang
    Cao, Guohua
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLIED SCIENCE AND ENGINEERING INNOVATION, 2015, 12 : 1333 - 1336