NOx Reduction by Air-Side Versus Fuel-Side Dilution in Hydrogen Diffusion Flame Combustors

被引:11
|
作者
Weiland, Nathan T. [1 ,2 ]
Strakey, Peter A. [3 ]
机构
[1] Natl Energy Technol Lab, Pittsburgh, PA 15236 USA
[2] W Virginia Univ, Dept Mech & Aerosp Engn, Morgantown, WV 26506 USA
[3] Natl Energy Technol Lab, Morgantown, WV 26507 USA
关键词
air pollution control; carbon compounds; combined cycle power stations; combustion; diffusion; flames; nitrogen compounds; stratified flow; thermal stability; GAS-TURBINE; EMISSIONS; STABILITY;
D O I
10.1115/1.4000268
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Lean-direct-injection (LDI) combustion is being considered at the National Energy Technology Laboratory as a means to attain low NOx emissions in a high-hydrogen gas turbine combustor. Integrated gasification combined cycle (IGCC) plant designs can create a high-hydrogen fuel using a water-gas shift reactor and subsequent CO2 separation. The IGCC's air separation unit produces a volume of N-2 roughly equivalent to the volume of H-2 in the gasifier product stream, which can be used to help reduce peak flame temperatures and NOx in the diffusion flame combustor. Placement of this diluent in either the air or fuel streams is a matter of practical importance, and it has not been studied to date for LDI combustion. The current work discusses how diluent placement affects diffusion flame temperatures, residence times, and stability limits, and their resulting effects on NOx emissions. From a peak flame temperature perspective, greater NOx reduction should be attainable with fuel dilution rather than air or independent dilution in any diffusion flame combustor with excess combustion air, due to the complete utilization of the diluent as a heat sink at the flame front, although the importance of this mechanism is shown to diminish as flow conditions approach stoichiometric proportions. For simple LDI combustor designs, residence time scaling relationships yield a lower NOx production potential for fuel-side dilution due to its smaller flame size, whereas air dilution yields a larger air entrainment requirement and a subsequently larger flame, with longer residence times and higher thermal NOx generation. For more complex staged-air LDI combustor designs, the dilution of the primary combustion air at fuel-rich conditions can result in the full utilization of the diluent for reducing the peak flame temperature, while also controlling flame volume and residence time for NOx reduction purposes. However, differential diffusion of hydrogen out of a diluted hydrogen/nitrogen fuel jet can create regions of higher hydrogen content in the immediate vicinity of the fuel injection point than can be attained with the dilution of the air stream, leading to increased flame stability. By this mechanism, fuel-side dilution extends the operating envelope to areas with higher velocities in the experimental configurations tested, where faster mixing rates further reduce flame residence times and NOx emissions. Strategies for accurate computational modeling of LDI combustors' stability characteristics are also discussed.
引用
收藏
页数:9
相关论文
共 45 条
  • [31] NOx formation in hydrogen-methane turbulent diffusion flame under the moderate or intense low-oxygen dilution conditions
    Gao, Xuan
    Duan, Fei
    Lim, Seng Chuan
    Yip, Mee Sin
    ENERGY, 2013, 59 : 559 - 569
  • [32] Effect of CO2 diluent on fuel versus oxidizer side of spherical diffusion flames in microgravity
    Chernovsky, M. K.
    Atreya, A.
    Im, H. G.
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2007, 31 : 1005 - 1013
  • [33] EXPERIMENTAL INVESTIGATION OF COMBUSTION OF A LIQUID-HYDROCARBON FUEL, ATOMIZED IN A DIFFUSION HYDROGEN-AIR FLAME
    ANNUSHKIN, YM
    MASLOV, GF
    COMBUSTION EXPLOSION AND SHOCK WAVES, 1981, 17 (05) : 509 - 513
  • [34] Effect of hydrogen percentage and air jet Reynolds number on fuel lean flame stability of LPG-fired inverse diffusion flame with hydrogen enrichment
    Miao, J.
    Leung, C. W.
    Cheung, C. S.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (01) : 602 - 609
  • [35] Effect of the tin- versus air-side plate-glass orientation on the impact response and penetration resistance of a laminated transparent armour structure
    Grujicic, M.
    Bell, W. C.
    Pandurangan, B.
    Cheeseman, B. A.
    Patel, P.
    Dehmer, P. G.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2012, 226 (L2) : 119 - 143
  • [36] Effect of hydrogen and helium addition to fuel on soot formation in an axisymmetric coflow laminar methane/air diffusion flame
    Liu, Fengshan
    Ai, Yuhua
    Kong, Wenjun
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (08) : 3936 - 3946
  • [37] Experimental and numerical study on NOx reduction from NH3/DME/air flame using fuel staging method
    Yu, Mingyu
    Luo, Guangqian
    Sun, Ruize
    Wang, Li
    Li, Xian
    Yao, Hong
    FUEL, 2024, 372
  • [38] Acoustic excitation effect on NOx reduction and flame stability in a lifted non-premixed turbulent hydrogen jet with coaxial air
    Oh, Jeongseog
    Heo, Pilwon
    Yoon, Youngbin
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2009, 34 (18) : 7851 - 7861
  • [39] Effects of hydrogen and helium addition to fuel on soot formation in axisymmetric coflow laminar methane-air diffusion flame
    Liu, Fengshan
    Migliorini, Francesca
    Cignoli, Francesco
    De Luliis, Silvana
    Zizak, Giorgio
    PROCEEDINGS OF THE ASME/JSME THERMAL ENGINEERING SUMMER HEAT TRANSFER CONFERENCE 2007, VOL 3, 2007, : 633 - 642
  • [40] Detailed multi-dimensional study on NOx formation and destruction mechanisms in dimethyl ether/air diffusion flame under the moderate or intense low-oxygen dilution (MILD) condition
    Kang, Yinhu
    Wei, Shuang
    Zhang, Pengyuan
    Lu, Xiaofeng
    Wang, Quanhai
    Gou, Xiaolong
    Huang, Xiaomei
    Peng, Shini
    Yang, Dong
    Ji, Xuanyu
    ENERGY, 2017, 119 : 1195 - 1211