Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants

被引:39
|
作者
Beer, S. [1 ]
Streun, M. [1 ]
Hombach, T. [2 ]
Buehler, J. [2 ]
Jahnke, S. [2 ]
Khodaverdi, M. [1 ]
Larue, H. [1 ]
Minwuyelet, S. [2 ]
Parl, C. [1 ]
Roeb, G. [2 ]
Schurr, U. [2 ]
Ziemons, K. [1 ]
机构
[1] Forschungszentrum Juelich, Cent Inst Elect, D-52425 Julich, Germany
[2] Forschungszentrum Juelich, ICG Phytosphere 3, D-52425 Julich, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 03期
关键词
SMALL ANIMAL PET; TRANSPORT; PHLOEM; LUYAP;
D O I
10.1088/0031-9155/55/3/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Positron emitters such as C-11, N-13 and F-18 and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is (CO2)-C-11 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET (TM) system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements.
引用
收藏
页码:635 / 646
页数:12
相关论文
共 50 条
  • [1] DESIGN OF A HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPH - NEURO-PET
    BROOKS, RA
    SANK, VJ
    DICHIRO, G
    FRIAUF, WS
    LEIGHTON, SB
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (01) : 5 - 13
  • [2] Design and performance evaluation of a high-resolution small animal positron tomograph
    Pavlopoulos, S
    Tzanakos, G
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3249 - 3255
  • [3] PlanTIS:: A Positron Emission Tomograph for Imaging 11C Transport in Plants
    Streuni, M.
    Beer, S.
    Hombach, T.
    Jahnke, S.
    Khodaverdi, M.
    Larue, H.
    Minwuyelet, S.
    Parl, C.
    Roeb, G.
    Schurr, U.
    Ziemons, K.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4110 - +
  • [4] HIGH-RESOLUTION TIME-OF-FLIGHT POSITRON EMISSION TOMOGRAPH
    ISHII, K
    ORIHARA, H
    MATSUZAWA, T
    BINKLEY, DM
    NUTT, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (12): : 3755 - 3762
  • [5] A BGO DETECTOR UNIT FOR A STATIONARY HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPH
    YAMAMOTO, S
    MIURA, S
    IIDA, H
    KANNO, I
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) : 851 - 855
  • [6] DESIGN OF A HIGH-RESOLUTION POSITRON EMISSION TOMOGRAPH USING SOLID-STATE SCINTILLATION DETECTORS
    CARRIER, C
    MARTEL, C
    SCHMITT, D
    LECOMTE, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 685 - 690
  • [7] HEADTOME-III - A HIGH QUANTITATION AND HIGH-RESOLUTION BRAIN POSITRON EMISSION TOMOGRAPH
    KANNO, I
    MIURA, S
    MURAKAMI, M
    UEMURA, K
    HIROSE, Y
    TAKAHASHI, S
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (05): : P46 - P46
  • [8] DESIGN AND ENGINEERING ASPECTS OF A HIGH-RESOLUTION POSITRON TOMOGRAPH FOR SMALL ANIMAL IMAGING
    LECOMTE, R
    CADORETTE, J
    RICHARD, P
    RODRIGUE, S
    ROULEAU, D
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (04) : 1446 - 1452
  • [9] CLINICAL-EVALUATION OF A HIGH-RESOLUTION (2.6-MM) POSITRON EMISSION TOMOGRAPH
    VALK, PE
    JAGUST, WJ
    DERENZO, SE
    HUESMAN, RH
    GEYER, AB
    BUDINGER, TF
    [J]. RADIOLOGY, 1990, 176 (03) : 783 - 790
  • [10] DONNER 280 CRYSTAL HIGH-RESOLUTION POSITRON TOMOGRAPH
    DERENZO, SE
    BUDINGER, TF
    CAHOON, JL
    GREENBERG, WL
    HUESMAN, RH
    VULETICH, T
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) : 2790 - 2793