Ion-selective carbon paste electrode based on tetraethyl thiuram disulfide for copper(II) and mercury(II)

被引:64
|
作者
Gismera, MJ [1 ]
Hueso, D [1 ]
Procopio, JR [1 ]
Sevilla, AT [1 ]
机构
[1] Univ Autonoma Madrid, Fac Ciencias, Dept Quim Analit & Anal Instrumental, E-28049 Madrid, Spain
关键词
copper; mercury; ion-selective electrode; carbon paste modified electrode; tetraethyl thiuram disulfide; humic acid;
D O I
10.1016/j.aca.2004.03.098
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tetraethyl thiuram disulfide was chosen as a chemical modifier in a carbon paste electrode for the potentiometric determination of copper(H) and mercury(II) ions. The electrode has wide linear response ranges and rapid response times. The pH influence on the potentiometric response is studied. Selectivity coefficients towards different cationic species are tabulated. The limits of detection are 10(-7.4) and 10(-7.6) M for copper (II) and mercury(II) activity, respectively. The electrode is employed in analyses of real samples and in potentiometric titrations. It is successfully used for potentiometric titration of humic acids in order to obtain information about the complexing properties of these acids. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:347 / 353
页数:7
相关论文
共 50 条
  • [41] A Mercury(II) Ion-selective Electrode Based on N,N-Dimethylformamide-salicylacylhydrazone as a Neutral Carrier
    Guangrong Ye
    Yaqin Chai
    Ruo Yuan
    Jianyuan Dai
    Analytical Sciences, 2006, 22 : 579 - 582
  • [42] A mercury(II) ion-selective electrode based on N,N-dimethylformamide-salicylacylhydrazone as a neutral carrier
    Ye, GR
    Chai, YQ
    Yuan, R
    Dai, JY
    ANALYTICAL SCIENCES, 2006, 22 (04) : 579 - 582
  • [44] Lead(II) and Copper(II) Ion-Selective Electrodes Based on Two Heterocyclic Compounds
    Yan, Zhenning
    Zhang, Qian
    Dan, Junying
    Guo, Yipeng
    Li, Liqin
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (10) : 974 - 980
  • [45] Lead(II) and copper(II) ion-selective electrodes based on two heterocyclic compounds
    Zhenning Yan
    Qian Zhang
    Junying Dan
    Yipeng Guo
    Liqin Li
    Journal of Analytical Chemistry, 2011, 66 : 974 - 980
  • [46] THE BEHAVIOR OF A CU(II) ION-SELECTIVE ELECTRODE IN SEAWATER - COPPER CONSUMPTION CAPACITY AND COPPER DETERMINATIONS
    ROMAN, DA
    RIVERA, L
    MARINE CHEMISTRY, 1992, 38 (3-4) : 165 - 184
  • [47] USE OF COPPER (II) ION-SELECTIVE ELECTRODE AND GRAN PLOTS IN THE SEQUENTIAL COMPLEXOMETRIC DETERMINATION OF COPPER (II), ZINC (II) AND IRON (III)
    STELLA, R
    VALENTINI, MTG
    BORRONI, PA
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1984, 17 (06): : 433 - 445
  • [48] FLOW-INJECTION DETERMINATION OF THE TOTAL WATER HARDNESS BY USING A COPPER(II) ION-SELECTIVE ELECTRODE AND A COPPER(II) ION BUFFER
    IMATO, T
    ISHII, K
    ISHIBASHI, N
    ANALYTICAL SCIENCES, 1992, 8 (05) : 631 - 635
  • [49] Formation of a Mercury Plated Carbon Paste Electrode by Electroreduction of a Mercury(II) Diethyldithiocarbamate Modified Carbon Paste
    S. X. Guo
    S. B. Khoo
    Environmental Monitoring and Assessment, 1997, 44 : 471 - 480
  • [50] THIURAM MONOSULFIDES AS A NEUTRAL CARRIER FOR COPPER(II)-SELECTIVE MEMBRANE-ELECTRODE
    KAMATA, S
    BHALE, A
    UDA, T