Ultrasound and MRI accordance and features in the prenatal diagnosis of placenta accreta

被引:2
|
作者
Lin, Ru [1 ]
Li, Jingtao [2 ]
Ren, Yunyun [1 ]
Cheng, Haidong [3 ]
机构
[1] Fudan Univ, Obstet & Gynecol Hosp, Dept Ultrasound, Shanghai 200011, Peoples R China
[2] Fudan Univ, Software Sch, Shanghai, Peoples R China
[3] Fudan Univ, Obstet & Gynecol Hosp, Dept Obstet, 419 Fangxie Rd, Shanghai 200011, Peoples R China
关键词
Placenta accrete; ultrasound; magnetic resonance imaging; image features; ACCURACY; ULTRASONOGRAPHY; PREVIA;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives: To analyze major image features of ultrasonography and magnetic resonance imaging (MRI), as well as the agreement between the two methods for the diagnosis of placenta accreta. Methods: A retrospective analysis was performed on 378 highly suspected cases of placenta accreta in Obstetrics and Gynaecology Hospital of Fudan University, by comparing ultrasound and MRI results with postpartum surgical pathology and clinical follow-up results. Results: Clinical and postpartum pathology confirmed 65 cases of placenta accreta. Ultrasound and MRI results showed a high level of agreement (Kappa approximate to 0.79). Ultrasound features with high accuracy (>60%) are as follows in the order of high to low: irregular blood flow signals in the basal portion of the placenta, intraplacental lacunae, placental thickening, thinning or disappearance of the hypoechoic retroplacental myometrial zone. The combination of the following three features has the largest Area Under Curve value (AUC, 0.93): Intraplacental lacunae, Thinning or disappearance of the hypoechoic retroplacental zone and Irregular blood flow signals in the basal portion of the placenta. MRI features with high accuracy (> 60%) are as follows: Dark intraplacental bands on T2-weighted images, heterogeneous signal intensity within the placenta, blurring or disappearance of the low-signal-intensity interface between the placenta and the myometrium. The combination of all 6 features listed in this article has the largest AUC (0.79). Conclusion: Ultrasonography, with a high accuracy, is still the main method for the diagnosis of placenta accreta. Combining multiple image features can improve the accuracy of diagnosis for both ultrasound and MRI.
引用
收藏
页码:8917 / 8925
页数:9
相关论文
共 50 条
  • [21] Placenta Accreta Spectrum Prenatal Diagnosis and Management
    Horgan, Rebecca
    Abuhamad, Alfred
    OBSTETRICS AND GYNECOLOGY CLINICS OF NORTH AMERICA, 2022, 49 (03) : 423 - 438
  • [22] Advances in Prenatal Diagnosis of Placenta Accreta Spectrum
    Chen, Qiuming
    Shen, Kuifang
    Wu, Yating
    Wei, Jianling
    Huang, Jingrui
    Pei, Chenlin
    MEDICINA-LITHUANIA, 2025, 61 (03):
  • [23] Prenatal Diagnosis of Placenta Accreta Spectrum Disorders: Deep Learning Radiomics of Pelvic MRI
    Peng, Lulu
    Yang, Zehong
    Liu, Jue
    Liu, Yi
    Huang, Jianwei
    Chen, Junwei
    Su, Yun
    Zhang, Xiang
    Song, Ting
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (02) : 496 - 509
  • [24] Texture analysis of placental MRI: can it aid in the prenatal diagnosis of placenta accreta spectrum?
    Eric Chen
    Winnie A. Mar
    Jeanne M. Horowitz
    Amanda Allen
    Priyanka Jha
    Donald R. Cantrell
    Kejia Cai
    Abdominal Radiology, 2019, 44 : 3175 - 3184
  • [25] Texture analysis of placental MRI: can it aid in the prenatal diagnosis of placenta accreta spectrum?
    Chen, Eric
    Mar, Winnie A.
    Horowitz, Jeanne M.
    Allen, Amanda
    Jha, Priyanka
    Cantrell, Donald R.
    Cai, Kejia
    ABDOMINAL RADIOLOGY, 2019, 44 (09) : 3175 - 3184
  • [26] Accuracy of ultrasound imaging for diagnosis of placenta accreta
    Bowman, Zachary
    Eller, Alexandra
    Kennedy, Anne
    Richards, Douglas
    Winter, Thomas
    Woodward, Paula
    Silver, Robert
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2014, 210 (01) : S72 - S72
  • [27] Placenta accreta: A review of current advances in prenatal diagnosis
    Mazouni, C.
    Gorincour, G.
    Juhan, V.
    Bretelle, F.
    PLACENTA, 2007, 28 (07) : 599 - 603
  • [28] Usefulness of decision tree analysis of MRI features for diagnosis of placenta accreta spectrum in cases with placenta previa
    Tanaka, Yasuhiro
    Ando, Hirofumi
    Miyamoto, Tsutomu
    Yokokawa, Yusuke
    Ono, Motoki
    Asaka, Ryoichi
    Kobara, Hisanori
    Fuseya, Chiho
    Kikuchi, Norihiko
    Ohya, Ayumi
    Fujinaga, Yasunari
    Shiozawa, Tanri
    JAPANESE JOURNAL OF RADIOLOGY, 2025, 43 (03) : 492 - 501
  • [29] Prenatal ultrasound staging system for placenta accreta spectrum disorders
    Cali, G.
    Forlani, F.
    Lees, C.
    Timor-Tritsch, I.
    Palacios-Jaraquemada, J.
    Dall'Asta, A.
    Bhide, A.
    Flacco, M. E.
    Manzoli, L.
    Labate, F.
    Perino, A.
    Scambia, G.
    D'Antonio, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2019, 53 (06) : 752 - 760
  • [30] Usefulness of gray-scale ultrasound and complementary color Doppler ultrasound in the prenatal diagnosis of placenta previa accreta
    Chou, MM
    Tseng, JJ
    Ho, ESC
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2005, 192 (04) : 1349 - 1349