Ultrasound and MRI accordance and features in the prenatal diagnosis of placenta accreta

被引:2
|
作者
Lin, Ru [1 ]
Li, Jingtao [2 ]
Ren, Yunyun [1 ]
Cheng, Haidong [3 ]
机构
[1] Fudan Univ, Obstet & Gynecol Hosp, Dept Ultrasound, Shanghai 200011, Peoples R China
[2] Fudan Univ, Software Sch, Shanghai, Peoples R China
[3] Fudan Univ, Obstet & Gynecol Hosp, Dept Obstet, 419 Fangxie Rd, Shanghai 200011, Peoples R China
关键词
Placenta accrete; ultrasound; magnetic resonance imaging; image features; ACCURACY; ULTRASONOGRAPHY; PREVIA;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives: To analyze major image features of ultrasonography and magnetic resonance imaging (MRI), as well as the agreement between the two methods for the diagnosis of placenta accreta. Methods: A retrospective analysis was performed on 378 highly suspected cases of placenta accreta in Obstetrics and Gynaecology Hospital of Fudan University, by comparing ultrasound and MRI results with postpartum surgical pathology and clinical follow-up results. Results: Clinical and postpartum pathology confirmed 65 cases of placenta accreta. Ultrasound and MRI results showed a high level of agreement (Kappa approximate to 0.79). Ultrasound features with high accuracy (>60%) are as follows in the order of high to low: irregular blood flow signals in the basal portion of the placenta, intraplacental lacunae, placental thickening, thinning or disappearance of the hypoechoic retroplacental myometrial zone. The combination of the following three features has the largest Area Under Curve value (AUC, 0.93): Intraplacental lacunae, Thinning or disappearance of the hypoechoic retroplacental zone and Irregular blood flow signals in the basal portion of the placenta. MRI features with high accuracy (> 60%) are as follows: Dark intraplacental bands on T2-weighted images, heterogeneous signal intensity within the placenta, blurring or disappearance of the low-signal-intensity interface between the placenta and the myometrium. The combination of all 6 features listed in this article has the largest AUC (0.79). Conclusion: Ultrasonography, with a high accuracy, is still the main method for the diagnosis of placenta accreta. Combining multiple image features can improve the accuracy of diagnosis for both ultrasound and MRI.
引用
收藏
页码:8917 / 8925
页数:9
相关论文
共 50 条
  • [1] Diagnostic accuracy of ultrasound and MRI in the prenatal diagnosis of placenta accreta
    Maher, Mohammad A.
    Abdelaziz, Ahmed
    Bazeed, Mohamed F.
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2013, 92 (09) : 1017 - 1022
  • [2] Utility of Ultrasound and MRI in Prenatal Diagnosis of Placenta Accreta: A Pilot Study
    Lim, Philip S.
    Greenberg, Marianne
    Edelson, Mitchell I.
    Bell, Karen A.
    Edmonds, Pamela R.
    Mackey, Amy M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (06) : 1506 - 1513
  • [3] Accuracy of placenta accreta prenatal diagnosis by ultrasound and MRI in a high-risk population
    de Marcillac, F. Daney
    Moliere, S.
    Pinton, A.
    Weingertner, A-S.
    Fritz, G.
    Viville, B.
    Roedlich, M-N
    Gaudineau, A.
    Sananes, N.
    Favre, R.
    Nisand, I.
    Langer, B.
    JOURNAL DE GYNECOLOGIE OBSTETRIQUE ET BIOLOGIE DE LA REPRODUCTION, 2016, 45 (02): : 198 - 206
  • [4] Perspective in diagnostic accuracy of prenatal ultrasound and MRI for placenta accreta
    Yang, Qiu-min
    Zhang, Chu
    Zhang, Yun-yun
    Liu, Cai-ning
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2025, 38 (01):
  • [5] HOW GOOD ARE ULTRASOUND AND MRI FOR THE DIAGNOSIS OF PLACENTA ACCRETA?
    Esakoff, Tania
    Sparks, Teresa
    Poder, Liina
    Kaimal, Anjali
    Kim, Lena
    Goldstein, Ruth
    Cheng, Yvonne
    Feldstein, Vickie
    Caughey, Aaron
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2008, 199 (06) : S189 - S189
  • [6] Ultrasound scoring system for prenatal diagnosis of placenta accreta spectrum
    Junling Zhang
    Hezhou Li
    Demin Feng
    Juan Wu
    Zhaoyu Wang
    Fan Feng
    BMC Pregnancy and Childbirth, 23
  • [7] Dynamic contrast enhanced MRI of the placenta: A tool for prenatal diagnosis of placenta accreta?
    Millischer, A. E.
    Deloison, B.
    Silvera, S.
    Ville, Y.
    Boddaert, N.
    Balvay, D.
    Siauve, N.
    Cuenod, C. A.
    Ttsatsaris, V.
    Sentilhes, L.
    Salomon, L. J.
    PLACENTA, 2017, 53 : 40 - 47
  • [8] Ultrasound scoring system for prenatal diagnosis of placenta accreta spectrum
    Zhang, Junling
    Li, Hezhou
    Feng, Demin
    Wu, Juan
    Wang, Zhaoyu
    Feng, Fan
    BMC PREGNANCY AND CHILDBIRTH, 2023, 23 (01)
  • [9] Comparative analysis of ultrasound and MRI in the diagnosis of placenta accreta spectrum
    Barzilay, Eran
    Brandt, Benny
    Gilboa, Yinon
    Kassif, Eran
    Achiron, Reuven
    Raviv-Zilka, Lisa
    Katorza, Eldad
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (21): : 4056 - 4059
  • [10] The Ultrasound Diagnosis of Placenta Accreta
    Comstock, Christine H.
    ULTRASOUND, 2007, 15 (04) : 208 - 214