Wireless induction coils embedded in diamond for power transfer in medical implants

被引:5
|
作者
Sikder, Md. Kabir Uddin [1 ,2 ,3 ]
Fallon, James [1 ,2 ,4 ]
Shivdasani, Mohit N. [1 ,2 ]
Ganesan, Kumaravelu [5 ]
Seligman, Peter [2 ]
Garrett, David J. [2 ,5 ]
机构
[1] Univ Melbourne, Dept Med Bion, Melbourne, Vic 3010, Australia
[2] Bion Inst, 384 Albert St, East Melbourne, Vic 3002, Australia
[3] Jahangirnagar Univ, Dept Phys, Dhaka 1342, Bangladesh
[4] Univ Melbourne, Dept Otolaryngol, Melbourne, Vic 3010, Australia
[5] Univ Melbourne, Dept Phys, Melbourne, Vic 3010, Australia
基金
英国医学研究理事会; 澳大利亚研究理事会;
关键词
Medical implant; Wireless power; Diamond; Braze; Silver ABA; Induction coil; RETINAL PROSTHESIS; SKIN THICKNESS; COMMUNICATION; STIMULATION; FABRICATION; DESIGN; ARRAY;
D O I
10.1007/s10544-017-0220-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wireless power and data transfer to medical implants is a research area where improvements in current state-of-the-art technologies are needed owing to the continuing efforts for miniaturization. At present, lithographical patterning of evaporated metals is widely used for miniature coil fabrication. This method produces coils that are limited to low micron or nanometer thicknesses leading to high impedance values and thus limiting their potential quality. In the present work we describe a novel technique, whereby trenches were milled into a diamond substrate and filled with silver active braze alloy, enabling the manufacture of small, high cross-section, low impedance microcoils capable of transferring up to 10 mW of power up to a distance of 6 mm. As a substitute for a metallic braze line used for hermetic sealing, a continuous metal loop when placed parallel and close to the coil surface reduced power transfer efficiency by 43%, but not significantly, when placed perpendicular to the microcoil surface. Encapsulation of the coil by growth of a further layer of diamond reduced the quality factor by an average of 38%, which can be largely avoided by prior oxygen plasma treatment. Furthermore, an accelerated ageing test after encapsulation showed that these coils are long lasting. Our results thus collectively highlight the feasibility of fabricating a high-cross section, biocompatible and long lasting miniaturized microcoil that could be used in either a neural recording or neuromuscular stimulation device.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Wireless Power Transfer With HTS Transmitting and Relaying Coils
    Yu, Hui
    Zhang, GuoMin
    Jing, Liwei
    Liu, Qi
    Yuan, Weijia
    Liu, Zhongjing
    Feng, Xianghua
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2015, 25 (03)
  • [22] Behavioral modeling of Wireless Power Transfer System coils
    Stoyka, Kateryna
    Di Mambro, Gennaro
    Femia, Nicola
    Maffucci, Antonio
    Ventre, Salvatore
    Villone, Fabio
    [J]. MATHEMATICS AND COMPUTERS IN SIMULATION, 2021, 183 : 208 - 220
  • [23] A Study of Loosely Coupled Coils for Wireless Power Transfer
    Chen, Chih-Jung
    Chu, Tah-Hsiung
    Lin, Chih-Lung
    Jou, Zeui-Chown
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2010, 57 (07) : 536 - 540
  • [24] AC Loss Behavior of Wireless Power Transfer Coils
    Utschick, Christoph
    Merz, Christian
    Som, Cem
    [J]. 2019 IEEE MTT-S WIRELESS POWER TRANSFER CONFERENCE (WPTC) / IEEE PELS WORKSHOP ON EMERGING TECHNOLOGIES: WIRELESS POWER (WOW) / WIRELESS POWER WEEK (WPW 2019), 2019, : 120 - 125
  • [25] Inductive Characteristics of Asymmetrical Coils for Wireless Power Transfer
    Ravikiran, Vaka
    Keshri, Ritesh Kumar
    Santos, Max Mauro
    [J]. 2017 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2017, : 538 - 542
  • [26] Metal Object Detection With Detection Coils Perpendicular to Power Coils for Wireless Power Transfer Systems
    Zhong, Wenxing
    Xiang, Fei
    Hu, Changsheng
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (09) : 10530 - 10534
  • [27] Wireless Power Transfer for Smart Knee Implants
    Jain, Manav
    Stanacevic, Milutin
    Willing, Ryan
    Towfighian, Sherry
    Salman, Emre
    [J]. 2022 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 22), 2022, : 1896 - 1900
  • [28] Safety Analysis of Medical Implants in the Human Head Exposed to a Wireless Power Transfer System
    Shah, Izaz Ali
    Basir, Abdul
    Cho, Youngdae
    Yoo, Hyoungsuk
    [J]. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2022, 64 (03) : 640 - 649
  • [29] Wireless Power Transfer System With High Misalignment Tolerance for Bio-Medical Implants
    Wang, Qinghua
    Che, Wenquan
    Mongiardo, Mauro
    Monti, Giuseppina
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2020, 67 (12) : 3023 - 3027
  • [30] Wireless power transfer technology for electric iron based on multi-coils induction heating design
    Meng, Lichan
    Cheng, Ka Wai Eric
    [J]. IET POWER ELECTRONICS, 2019, 12 (10) : 2566 - 2577