High-precision half-life determination of 14O via direct β counting

被引:0
|
作者
Sharma, S. [1 ]
Grinyer, G. F. [1 ]
Ball, G. C. [2 ]
Leslie, J. R. [3 ]
Svensson, C. E. [4 ]
Ali, F. A. [4 ,9 ]
Andreoiu, C. [5 ]
Bernier, N. [2 ,6 ,10 ,11 ]
Bhattacharjee, S. S. [2 ]
Bildstein, V [4 ]
Burbadge, C. [4 ]
Caballero-Folch, R. [2 ]
Coleman, R. [4 ]
Varela, A. Diaz [4 ]
Dunlop, M. R. [4 ]
Dunlop, R. [4 ]
Garnsworthy, A. B. [2 ]
Fuakye, E. Gyabeng [1 ]
Huber, G. M. [1 ]
Jigmeddorj, B. [4 ]
Kapoor, K. [1 ]
Laffoley, A. T. [4 ]
Leach, K. G. [7 ]
Long, J. [8 ]
MacLean, A. D. [4 ]
Natzke, C. R. [2 ,7 ]
Olaizola, B. [2 ,12 ]
Radich, A. J. [4 ]
Saei, N. [1 ]
Smallcombe, J. T. [2 ,13 ]
Talebitaher, A. [1 ]
Whitmore, K. [5 ]
Zidar, T. [4 ]
机构
[1] Univ Regina, Dept Phys, Regina, SK S4S 0A2, Canada
[2] TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[3] Queens Univ, Kingston, ON K7L 3N6, Canada
[4] Univ Guelph, Dept Phys, Guelph, ON N1G 2W1, Canada
[5] Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada
[6] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 1Z4, Canada
[7] Colorado Sch Mines, Dept Phys, Golden, CO 80401 USA
[8] Univ Notre Dame, Dept Phys, Notre Dame, IN 46556 USA
[9] Univ Sulaimani, Coll Educ, Dept Phys, POB 334, Sulaimani, Kurdistan Regio, Iraq
[10] Univ Western Cape, Dept Phys & Astron, P-B X17, ZA-7535 Bellville, South Africa
[11] Univ Zululand, Dept Phys & Engn, PB X1001, ZA-3886 Kwa Dlangezwa, South Africa
[12] CERN, ISOLDE, CH-1211 Geneva 23, Switzerland
[13] Univ Liverpool, Oliver Lodge Lab, Liverpool L69 7ZE, Merseyside, England
来源
EUROPEAN PHYSICAL JOURNAL A | 2022年 / 58卷 / 05期
基金
加拿大自然科学与工程研究理事会;
关键词
DECAY; LIVES;
D O I
10.1140/epja/s10050-022-00730-w
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The half-life of the superallowed Fermi beta(+) emitter O-14 was determined to high precision via a direct beta counting experiment performed at the Isotope Separator and Accelerator (ISAC) facility at TRIUMF. The result, T-1/2(O-1(4)) = 70619.2(76) ms, is consistent with, but is more precise than, the world average obtained from 11 previous measurements. Combining the O-14 half-life deduced in the present work with the previous most precise measurements of this quantity leads to a reduction in the overall uncertainty, by nearly a factor of 2. The new world average is T-1/2(O-1(4)) = 70619.6(63) ms with a reduced chi(2) value of 0.87 obtained from 8 degrees of freedom.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] High-precision half-life determination for 21Na using a 4π gas-proportional counter
    Finlay, P.
    Laffoley, A. T.
    Ball, G. C.
    Bender, P. C.
    Dunlop, M. R.
    Dunlop, R.
    Hackman, G.
    Leslie, J. R.
    MacLean, A. D.
    Miller, D.
    Moukaddam, M.
    Olaizola, B.
    Severijns, N.
    Smith, J. K.
    Southall, D.
    Svensson, C. E.
    PHYSICAL REVIEW C, 2017, 96 (02)
  • [22] A DETERMINATION OF THE HALF-LIFE OF CARBON-14
    JONES, WM
    PHYSICAL REVIEW, 1949, 76 (07): : 885 - 889
  • [23] A DETERMINATION OF HALF-LIFE OF 14C
    BELLA, F
    ALESSIO, M
    FRATELLI, P
    NUOVO CIMENTO B, 1968, 58 (01): : 232 - &
  • [24] The half-life of 198Au : High-precision measurement shows no temperature dependence
    J. R. Goodwin
    V. V. Golovko
    V. E. Iacob
    J. C. Hardy
    The European Physical Journal A, 2007, 34 : 271 - 274
  • [25] High-precision half-life measurements for the superallowed Fermi β+ emitter 18Ne
    Laffoley, A. T.
    Svensson, C. E.
    Andreoiu, C.
    Ball, G. C.
    Bender, P. C.
    Bidaman, H.
    Bildstein, V.
    Blank, B.
    Cross, D. S.
    Deng, G.
    Varela, A. Diaz
    Dunlop, M. R.
    Dunlop, R.
    Garnsworthy, A. B.
    Garrett, P. E.
    Giovinazzo, J.
    Grinyer, G. F.
    Grinyer, J.
    Hackman, G.
    Hadinia, B.
    Jamieson, D. S.
    Jigmeddorj, B.
    Kisliuk, D.
    Leach, K. G.
    Leslie, J. R.
    MacLean, A. D.
    Miller, D.
    Mills, B.
    Moukaddam, M.
    Radich, A. J.
    Rajabali, M. M.
    Rand, E. T.
    Thomas, J. C.
    Turko, J.
    Unsworth, C.
    Voss, P.
    PHYSICAL REVIEW C, 2015, 92 (02)
  • [26] High-precision half-life measurement for the superallowed Fermi β+ emitter 22Mg
    Dunlop, M. R.
    Svensson, C. E.
    Ball, G. C.
    Leslie, J. R.
    Andreoiu, C.
    Bernier, N.
    Bidaman, H.
    Bildstein, V.
    Bowry, M.
    Burbadge, C.
    Caballero-Folch, R.
    Varela, A. Diaz
    Dunlop, R.
    Garnsworthy, A. B.
    Garrett, P. E.
    Hackman, G.
    Jigmeddorj, B.
    Leach, K. G.
    MacLean, A. D.
    Olaizola, B.
    Measures, J.
    Natzke, C.
    Saito, Y.
    Smith, J. K.
    Turko, J.
    Zidar, T.
    PHYSICAL REVIEW C, 2017, 96 (04)
  • [27] The half-life of 198Au:: High-precision measurement shows no temperature dependence
    Goodwin, J. R.
    Golovko, V. V.
    Iacob, V. E.
    Hardy, J. C.
    EUROPEAN PHYSICAL JOURNAL A, 2007, 34 (03): : 271 - 274
  • [28] A PRECISION DETERMINATION OF THE HALF-LIFE OF RADIUM-C'
    VONDARDEL, G
    PHYSICAL REVIEW, 1950, 79 (04): : 734 - 735
  • [29] HALF-LIFE DETERMINATION OF PO-210 BY ALPHA COUNTING
    CURTIS, ML
    PHYSICAL REVIEW, 1953, 92 (06): : 1489 - 1489
  • [30] HIGH-PRECISION HALF-LIFE AND BRANCHING RATIO MEASUREMENTS FOR THE SUPERALLOWED β+ EMITTER 26Alm
    Finlay, P.
    Svensson, C. E.
    Demand, G. A.
    Garrett, P. E.
    Green, K. L.
    Leach, K. G.
    Phillips, A. A.
    Rand, E. T.
    Ball, G.
    Bandyopadhyay, D.
    Djongolov, M.
    Ettenauer, S.
    Hackman, G.
    Pearson, C. J.
    Leslie, J. R.
    Andreoiu, C.
    Cross, D.
    Austin, R. A. E.
    Grinyer, G. F.
    Sumithrarachchi, C. S.
    Williams, S. J.
    Triambak, S.
    CAPTURE GAMMA-RAY SPECTROSCOPY AND RELATED TOPICS, 2013, : 415 - 420