The Measurements of Uranium Concentration in Human Blood in Selected Regions in Iraq Using CR-39 Track Detector

被引:9
|
作者
Al-Hamzawi, Anees A. [1 ,2 ]
Jaafar, M. S. [1 ]
Tawfiq, Nada F. [3 ]
机构
[1] Univ Sains Malaysia, Sch Phys, George Town 11800, Malaysia
[2] Qadisiya Univ, Coll Educ, Dept Phys, Qadisiya, Iraq
[3] Nahrin Univ, Coll Sci, Dept Phys, Baghdad, Iraq
来源
关键词
Basrah; CR-39; human blood; fission track; uranium concentration;
D O I
10.4028/www.scientific.net/AMR.925.679
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The technique of fission track has been applied to determine the concentration of uranium in blood samples for people, male and female of Basrah city (south of Iraq), using CR-39 track detector. During the Gulf Wars I and II in 1991 and 2003 respectively, this city became a place of military operations. The measurements were done for samples of human blood for people to study the impact of exposure in this city as compared to results from Babylon city (central Iraq); the latter is far from exposure locations. The results showed that the uranium concentrations in human blood of people in Basrah city ranged from 0.83 ppb to 2.47 while for people in Babylon city, the uranium concentration ranged from 0.3 ppb to 1.59 ppb. It has also been found that the uranium concentration in human blood samples of people in Basrah city is higher than those of people in Babylon city. Results showed statistically significant differences in the uranium concentration in the residential area.
引用
收藏
页码:679 / +
页数:2
相关论文
共 50 条
  • [21] Measuring Radon Concentration Levels in Fertilizers using CR-39 Detector
    Aswood, Murtadha Sh
    Jaafar, Mohamad S.
    Bauk, Sabar
    MICRO/NANO SCIENCE AND ENGINEERING, 2014, 925 : 610 - +
  • [22] Using UV Irradiation to Shorten Track Formation Time on CR-39 Detector
    El-Farrash, A. H.
    Abdelghany, A. M.
    Yousef, Hesham A.
    Mekhimar, M.
    Najim, S. M.
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2015, 6 (06):
  • [23] FAST-NEUTRON DOSIMETRY USING A CR-39 PLASTIC TRACK DETECTOR
    KHAN, HA
    KHAN, NA
    NUCLEAR INSTRUMENTS & METHODS, 1980, 178 (2-3): : 491 - 497
  • [24] Mass resolution for iron isotopes in CR-39 track detector
    Kodaira, S
    Hasebe, N
    Doke, T
    Kitagawa, A
    Kitamura, H
    Sato, S
    Uchihori, Y
    Yasuda, N
    Ogura, K
    Tawara, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2004, 43 (9A): : 6358 - 6363
  • [25] Calibration of CR-39 solid state nuclear track detector
    P. Wanabongse
    B. Sola
    J. Jamsangtong
    S. Rattanabussayaporn
    Indian Journal of Physics, 2009, 83 : 833 - 837
  • [26] Calibration study on the triton response of CR-39 track detector
    Yamauchi, T
    Oda, K
    Tanabe, S
    Matsumoto, H
    Miyake, H
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 191 - 196
  • [27] APPLICATIONS OF CR-39 NUCLEAR TRACK DETECTOR IN MEDICINE AND TECHNOLOGY
    HENSHAW, DL
    PHYSICS IN TECHNOLOGY, 1982, 13 (06): : 266 - &
  • [29] A METHOD TO PROTECT CR-39 TRACK DETECTOR FROM SUNLIGHT
    AHMAD, N
    MIRZA, NM
    MIRZA, SM
    TUFAIL, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1991, 30 (07): : 1521 - 1522
  • [30] Calibration of solid state nuclear track detector CR-39
    Ren, GX
    Jing, GR
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (06): : 596 - 598