Changes in the clinical measurement of visual acuity

被引:7
|
作者
Bailey, I. L. [1 ]
Jackson, A. J. [2 ]
机构
[1] Univ Calif Berkeley, Sch Optometry, Berkeley, CA 94720 USA
[2] Royal Victoria Hosp, Ophthalmol, Belfast BT12 6BA, Antrim, North Ireland
关键词
D O I
10.1088/1742-6596/772/1/012046
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In 1862, Hermann Snellen introduced his letter chart for the clinical measurement of visual acuity. His chart presented letters,or optotypes, arranged in a progressively diminishing size sequence, and the visual acuity was determined by the smallest letters that could read at a specified distance. Numerous modifications of the design of the optotypes, the progression of size and the chart layout were suggested, and in 1976, Bailey and Lovie published a set of design principles that made the visual task the same at all size levels, so that size become the only significant variable. This required the same number of letters at each size level, fixed spacing ratios and a logarithmic progression of size. This facilitates more precise quantification of visual acuity by giving credit for every letter read correctly, and this gives clinicians tighter confidence limits for determining changes or differences in visual acuity. However, optotype choices, and associated spacing arrangements can have significant effects on visual acuity scores as can viewing conditions and testing protocols. Computer based visual acuity tests are becoming more commonplace, there will be more variety in test charts and procedures which will create some problems for making comparisons between tests.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] CLINICAL TESTING OF VISUAL ACUITY
    EHLERS, H
    AMA ARCHIVES OF OPHTHALMOLOGY, 1953, 49 (04): : 431 - 434
  • [12] Toward the Optimum Measurement of Visual Acuity
    Redmond, Tony
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (11) : 7424 - 7424
  • [13] Dynamic visual acuity and methods of measurement
    Erdinest, Nir
    London, Naomi
    JOURNAL OF OPTOMETRY, 2022, 15 (03) : 247 - 248
  • [14] SIMULATED AUTOMATED VISUAL ACUITY MEASUREMENT
    MARG, E
    LIBERMAN, G
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1967, 44 (10): : 669 - &
  • [15] On the measurement of the stereoscopic visual acuity.
    James, GTB
    LANCET, 1908, 1 : 1763 - 1766
  • [16] Functional visual acuity measurement in glaucoma
    Sato, Haruka
    Kunikata, Hiroshi
    Ouchi, Junko
    Nakazawa, Toru
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 (04): : 414 - 415
  • [17] VISUAL-ACUITY MEASUREMENT STANDARD
    ARDEN, GB
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1988, 11 (11): : 779 - 792
  • [18] OBJECTIVE MEASUREMENT OF VISUAL ACUITY BY ARRESTOVISIOGRAPHY
    VOIPIO, H
    HYVARINEN, L
    ARCHIVES OF OPHTHALMOLOGY, 1966, 75 (06) : 799 - +
  • [19] Stability of visual acuity measurement in depression
    Rovner, BW
    Casten, R
    AMERICAN JOURNAL OF GERIATRIC PSYCHIATRY, 2005, 13 (03): : 255 - 258
  • [20] A need for standardization in visual acuity measurement
    Patel, Hina
    Congdon, Nathan
    Strauss, Glenn
    Lansingh, Charles
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2017, 80 (05) : 332 - 337