Equivalent PI Circuit for Zero-sequence Networks of Parallel Transmission Lines

被引:12
|
作者
Liao, Yuan [1 ]
机构
[1] Univ Kentucky, Dept Elect & Comp Engn, Lexington, KY 40506 USA
基金
美国国家科学基金会;
关键词
distributed parameter line model; double-circuit transmission line; equivalent PI circuit; fault analysis and protection; parallel transmission line;
D O I
10.1080/15325000902762349
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The equivalent PI circuit for single-circuit lines is well established in the literature based on the distributed parameter line model. However, the equivalent circuit for the mutually coupled zero-sequence networks of a double-circuit line has not yet been adequately addressed. This article endeavors to derive the equivalent PI circuit for the zero-sequence networks of a double-circuit line based on the distributed parameter model. The parameters of the equivalent circuits have a closed analytical form in terms of the line parameters in per-unit length. A numerical example is provided to demonstrate the application of the proposed method.
引用
收藏
页码:787 / 797
页数:11
相关论文
共 50 条
  • [21] Coordination of Superconductive Fault Current Limiters With Zero-Sequence Current Protection of Transmission Lines
    Li, Bin
    Li, Chao
    Guo, Fengrui
    Xin, Ying
    Wang, Chuncheng
    Pang, Xueyue
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2014, 24 (05)
  • [22] Mixed-measurement of Zero-sequence Parameters of Parallel Coupled Transmission lines Based on Variable-frequency Electrical Measurement
    Niu, Shengsuo
    Zhang, Jia
    Liang, Zhirui
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING AND INTELLIGENT SYSTEMS (ICMEIS 2015), 2015, 26 : 794 - 799
  • [23] Effects of Longitudinal Fault on Pilot Zero-sequence Directional Component in Four Parallel Transmission Lines Under Different Voltage Levels
    Chen, Wenzhe
    Dang, Yiqi
    2018 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2018 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2018,
  • [24] Zero-Sequence Voltages of UHV Untransposed Double-Circuit Lines and Their Influence on Pilot Protection
    Liao, Huiqin
    Li, Bin
    Li, Zhongqing
    Du, Dingxiang
    Jiang, Xianguo
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 846 - 851
  • [25] Unbalanced currents of EHV multi-circuit lines and coordination of zero-sequence overcurrent relayings
    Li, Bin
    Wang, Wenbo
    Wen, Weijie
    Yao, Bin
    He, Jiawei
    Wang, Xingguo
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 126
  • [26] An Improved Zero-sequence Directional Element for Parallel Lines Based on Fast Phasor Extracting Algorithm
    Ding, Jun
    Kang, Xiaoning
    Yang, Liming
    Hojo, Masahide
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [27] Zero Sequence Parameters Measurement of Triple-circuit Non-full-line Parallel Transmission Lines
    Gao M.
    Hu Z.
    Ni S.
    Liu Y.
    Dianwang Jishu/Power System Technology, 2022, 46 (04): : 1539 - 1547
  • [28] ZERO-SEQUENCE CURRENT DISTRIBUTION FOR DOUBLE CIRCUIT TRANSMISSION-LINE WITH SINGLE GROUND WIRE
    KHALEK, MGA
    PERIODICA POLYTECHNICA-ELECTRICAL ENGINEERING, 1978, 22 (04): : 223 - 228
  • [29] Zero-Sequence Impedance Estimation in Mutually Coupled Transmission Lines Using Fault Record Data
    Gashteroodkhani, Oveis Asgari
    Majidi, Mehrdad
    Etezadi-Amoli, Mehdi
    2020 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2020,
  • [30] Parameters estimation for zero-sequence parameter on-line measurement of transmission lines with mutual inductance
    Xue, Zhi-Ying
    Liang, Zhi-Rui
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (04): : 954 - 959