Interrupted tension-tension fatigue behavior of angle-ply GFRP composite laminates

被引:28
|
作者
Movahedi-Rad, A. Vahid [1 ]
Keller, Thomas [1 ]
Vassilopoulos, Anastasios P. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Composite Construct Lab CCLab, Stn 16,Batiment BP, CH-1015 Lausanne, Switzerland
基金
瑞士国家科学基金会;
关键词
Fatigue; Interrupted loading; Failure; Damage mechanism; Dissipated energy; Self-generated temperature; STRESS RATIO; CRACK-GROWTH; RETARDATION; DAMAGE; CREEP;
D O I
10.1016/j.ijfatigue.2018.05.001
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The effect of load interruptions on the tension-tension fatigue behavior of angle-ply (+/- 45)(2S) glass/epoxy composite laminates was investigated. The cyclic loading was interrupted for two hours at regular cycle intervals, corresponding to 20% of the fatigue life under continuous loading at the same maximum cyclic stress level. Fatigue stiffness was partially restored after each loading interruption due to the recovery of the viscoelastic polymeric matrix. This repeated material stiffening at the beginning of each loading block delayed crack growth. Crack blunting further delayed damage growth and caused a more uniform damage distribution throughout the specimen volume. By applying interrupted fatigue loading, the rates of stiffness degradation and energy dissipation per cycle decreased due to the delayed damage growth. In addition, more uniform damage growth throughout the specimen volume increased the specimen's capacity to accumulate damage, which led to a lower stiffness at failure, greater energy dissipation per cycle at failure and higher total dissipated energy of specimens subjected to interrupted loading. The specimens loaded under interrupted fatigue therefore exhibited longer fatigue lives than those continuously loaded. This enhancement of fatigue life increased at higher stress levels but almost disappeared at low levels. It was thus concluded that fatigue design allowables, if determined on the basis of continuous fatigue, are conservative in the case of interrupted fatigue.
引用
收藏
页码:377 / 388
页数:12
相关论文
共 50 条
  • [11] A criterion for failure mode prediction of angle-ply composite laminates under in-plane tension
    Dong, H.
    Wang, J.
    COMPOSITE STRUCTURES, 2015, 128 : 234 - 240
  • [12] Cryogenic fatigue behavior of plain weave glass/epoxy composite laminates under tension-tension cycling
    Shindo, Yasuhide
    Takano, Satoru
    Horiguchi, Katsumi
    Sato, Takashi
    CRYOGENICS, 2006, 46 (11) : 794 - 798
  • [13] Fatigue behavior of textile composite materials subjected to tension-tension loads
    Gowayed, Y
    Fan, H
    POLYMER COMPOSITES, 2001, 22 (06) : 762 - 769
  • [14] Tension-tension fatigue of hybrid composite rods
    Kar, N. K.
    Hu, Y.
    Barjasteh, E.
    Nutt, S. R.
    COMPOSITES PART B-ENGINEERING, 2012, 43 (05) : 2115 - 2124
  • [15] Prediction of transverse crack multiplication of CFRP cross-ply laminates under tension-tension fatigue load
    Kitagawa, Youzou
    Arai, Masahiro
    Yoshimura, Akinori
    Goto, Keita
    ADVANCED COMPOSITE MATERIALS, 2023, 32 (03) : 419 - 436
  • [16] Effect of stress ratio on the tension-tension fatigue behavior of tungsten carbide nanoparticles toughened GFRP
    Radhakrishnan, P. M.
    Bharadwaj, S.
    Sudhi, G.
    Ramajeyathilagam, K.
    FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2023, 46 (08) : 2949 - 2965
  • [17] Analytical and experimental investigation of tensile properties of cross-ply and angle-ply GFRP composite laminates
    Bourchak, Mostefa
    Harasani, Wail
    SCIENCE AND ENGINEERING OF COMPOSITE MATERIALS, 2015, 22 (03) : 297 - 301
  • [18] Width effects on the tensile strength and fatigue behavior of angle-ply laminates
    Western Michigan Univ, Kalamazoo, United States
    Int J Fatigue, 8 (575-580):
  • [20] FLEXURAL FAILURE ANALYSIS OF ANGLE-PLY LAMINATES OF GFRP AND CFRP
    TURVEY, GJ
    JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 1980, 15 (01): : 43 - 49