Morning pulmonary artery pressure measurements by CardioMEMS are most stable and recommended for pressure trends monitoring

被引:2
|
作者
Crnko, S. [1 ,2 ]
Brugts, J. J. [3 ]
Veenis, J. F. [3 ]
de Jonge, N. [1 ]
Sluijter, J. P. G. [1 ,2 ,4 ]
Oerlemans, M. I. F. [1 ]
van Laake, L. W. [1 ,2 ]
机构
[1] Univ Med Ctr Utrecht, Dept Cardiol & Expt Cardiol, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Regenerat Med Ctr, Circulatory Hlth Lab, Utrecht, Netherlands
[3] Erasmus MC Univ Med Ctr, Dept Cardiol, Rotterdam, Netherlands
[4] Univ Utrecht, Utrecht, Netherlands
关键词
Heart failure; CardioMEMS; Circadian rhythm; Individualised therapy; Telemonitoring; HEART-FAILURE; DIURNAL-VARIATION;
D O I
10.1007/s12471-021-01590-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims The CardioMEMS HF system is used to measure pulmonary artery (PA) pressures of patients with heart failure (HF). The goal of this study was to determine the impact of time in the daily PA pressure measurements, considering variance and influence of circadian rhythms on cardiovascular pathophysiology. Methods and results The study included 10 patients with HF with reduced ejection fraction (LVEF < 40%; New York Heart Association class III). Individual daily PA pressures were obtained by CardioMEMS sensors, per protocol, measured up to six times throughout the day, for a period of 5 days. Differences between variation of morning versus evening PA pressures were compared with Wilcoxon signed-rank test. Mean PA pressures (mPAP) increased from a morning value of 19.1 +/- 2 mm Hg (8 am; mean +/- standard error of the mean [SEM]) to 21.3 +/- 2 mm Hg late in the evening (11 pm; mean +/- SEM). Over the course of 5 days, evening mPAP exhibited a significantly higher median coefficient of variation than morning mPAP (14.9 (interquartile range [IQR] 7.6-21.0) and 7.0 (IQR 5.0-12.8) respectively; p = 0.01). The same daily pattern of pressure variability was observed in diastolic (p = 0.01) and systolic (p = 0.04) pressures, with diastolic pressures being more variable than systolic at all time points. Conclusions Morning PA pressure measurements yield more stable values for observing PA trends. Patients should thus be advised to consistently perform their daily PA pressure measurements early in the morning. This will improve reliability and interpretation of the CardioMEMS management, indicating true alterations in the patient's health status, rather than time-of-day-dependent variations.
引用
收藏
页码:409 / 414
页数:6
相关论文
共 50 条
  • [31] Monitoring pulmonary artery wedge pressure in medical patients
    Sharma, S
    Eagle, KA
    AMERICAN FAMILY PHYSICIAN, 1996, 54 (03) : 1039 - 1049
  • [32] Pulmonary artery pressure variation in patients with connective tissue disease: 24 hour ambulatory pulmonary artery pressure monitoring
    Raeside, DA
    Chalmers, G
    Clelland, J
    Madhok, R
    Peacock, AJ
    THORAX, 1998, 53 (10) : 857 - 862
  • [33] A position of home blood pressure measurements in the morning in relation to daytime ambulatory blood pressure monitoring: Morning surge in a population of Ohasama, Japan
    Imai, Y
    Tsuji, I
    Ohkubo, T
    Ito, S
    Satoh, H
    Nagai, K
    Hisamichi, S
    JOURNAL OF HYPERTENSION, 1998, 16 : S271 - S271
  • [34] SIMULTANEOUS MEASUREMENT OF PULMONARY ARTERY DIASTOLIC PRESSURE BY CARDIOMEMS DEVICE AND LEFT ATRIAL PRESSURE MEASUREMENT BY TRANSTHORACIC ECHOCARDIOGRAM IN HEART FAILURE POPULATION
    Tolia, Sunit Y.
    Khan, Zubair
    Kassem, Hassan
    Zughaib, Marcel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 938 - 938
  • [35] A New Physiological Control Strategy based on the CardioMEMS Pulmonary Artery Pressure Sensor for Rotary Blood Pumps
    Peng, Jing
    Wang, Zhiguo
    Qin, Kairong
    Luan, Yong
    Giridharan, Guruprasad A.
    El-Baz, Ayman
    Sethu, Palaniappan
    Wang, Yu
    2020 IEEE 16TH INTERNATIONAL CONFERENCE ON CONTROL & AUTOMATION (ICCA), 2020, : 1512 - 1517
  • [36] Cost-effectiveness of remote haemodynamic monitoring by an implantable pulmonary artery pressure monitoring sensor (CardioMEMS-HF system) in chronic heart failure in the Netherlands
    Mokri, Hamraz
    Clephas, Pascal R. D.
    de Boer, Rudolf A.
    van Baal, Pieter
    Brugts, Jasper J.
    Rutten-van Molken, Maureen P. M. H.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 (05) : 1189 - 1198
  • [37] Late Migration of a CardioMEMS™ Wireless Pulmonary Artery Hemodynamic Monitoring Sensor
    Rali, Aniket S.
    Shah, Zubair
    Sauer, Andrew
    Gupta, Kamal
    CIRCULATION-HEART FAILURE, 2017, 10 (04)
  • [38] PRESSURE IN PULMONARY ARTERY
    SLONIM, MS
    NEW ENGLAND JOURNAL OF MEDICINE, 1968, 278 (04): : 224 - &
  • [39] MISINTERPRETATION OF PRESSURE MEASUREMENTS FROM THE PULMONARY-ARTERY CATHETER
    NADEAU, S
    NOBLE, WH
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1986, 33 (03) : 352 - 363
  • [40] Natriuretic peptide dynamics with remote pulmonary artery pressure monitoring
    Casquete, D.
    Codina, P.
    Domingo, M.
    Santiago, E.
    Cediel, G.
    Spitaleri, G.
    Zamora, E.
    Santesmases, J.
    Boldo, M.
    Rivas, C.
    Gonzalez, B.
    Velayos, P.
    Pulido, A.
    Lupon, J.
    Bayes-Genis, A.
    EUROPEAN HEART JOURNAL, 2021, 42 : 1031 - 1031