Optical observation of shear waves excited by focused ultrasound in a tissue-mimicking phantom

被引:0
|
作者
Callé, S [1 ]
Remenieras, JP [1 ]
Matar, OB [1 ]
Patat, F [1 ]
机构
[1] GIP Ultrasons, LUSSI EA2102, Tours, France
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Acoustic radiation force imaging is a new approach to characterize mechanical properties of soft tissues. This method provides to the physician a virtual "finger" to probe the elasticity of internal regions. The tissue response to the impulse stress caused by the localized radiation force can be described by the elastodynamic Green function: the remotely induced displacements are mainly created by shear waves. This work describes how an optical interferometric method can be used to study both the displacements induced by the radiation force at the focal point and the axial shear displacement along the radial direction around the focal point of the transducer. A tissue-mimicking phantom including a 1 mum thick metallized sheet of Mylar is placed in a water tank. While the transient shear wave propagates, this reflective target moves with the tissue. The central plane of the phantom was positioned between the transducer and the laser beam, perpendicular to both ultrasonic and laser beams. The laser beam propagates in the optically transparent phantom and is reflected back by the Mylar. A 1 MHz transducer focalizes at the optical focal point. By moving the transducer and continuously measuring the displacement at the same location with the laser probe, we can reconstruct the temporal and spatial behavior of axial shear displacement along the radial direction around the focal point of the transducer. From these displacement measurements, attenuation and celerity distributions of this shear wave are extracted. By using this configuration (for pressures in the MPa range), displacements in the gin range can be measured with a noise level of 2 nm whereas the ultrasonic methods usually used to measure these tissue displacements have a noise level of 1 mum.
引用
收藏
页码:1851 / 1854
页数:4
相关论文
共 50 条
  • [31] Absolute Ultrasound Perfusion Parameter Quantification of a Tissue-Mimicking Phantom Using Bolus Tracking
    Mezl, Martin
    Jirik, Radovan
    Harabis, Vratislav
    Kolar, Radim
    Standara, Michal
    Nylund, Kim
    Gilja, Odd Helge
    Taxt, Torfinn
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (05) : 983 - 987
  • [32] MICROSCOPIC MECHANISM OF ATTENUATION OF COMPRESSIONAL ULTRASONIC-WAVES IN TISSUE-MIMICKING PHANTOM MATERIALS
    WU, EX
    GOODSITT, MM
    MADSEN, EL
    ULTRASONIC IMAGING, 1992, 14 (02) : 121 - 133
  • [33] Quality Assurance for Ultrasound Scanners using a durable tissue-mimicking Phantom and radial MTF
    Kaar, Marcus
    Semturs, Friedrich
    Figl, Michael
    Hoffmann, Rainer
    Hummel, Johann
    MEDICAL IMAGING 2014: ULTRASONIC IMAGING AND TOMOGRAPHY, 2014, 9040
  • [34] Design and characterization of a tissue-mimicking phantom for ultrasonic elastography
    Ling, Tao
    Jin, Qiaofeng
    Yao, Hui
    Zheng, Hairong
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [35] A multiparameter tissue-mimicking phantom for multispectral endoscopic imaging
    Gao, Xingjun
    Wu, Zhisheng
    Chen, Xiaopeng
    Wang, Liqiang
    Qi, Ji
    Yang, Qing
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XIII, 2023, 12770
  • [36] DEVELOPMENT OF A TISSUE-MIMICKING PHANTOM OF THE BRAIN FOR ULTRASONIC STUDIES
    Taghizadeh, Somayeh
    Labuda, Cecille
    Mobley, Joel
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (12): : 2813 - 2820
  • [37] Erosion of Tissue-Mimicking Phantom by Acoustic Droplet Vaporization
    Lin, Yi-Chen
    Kang, Shih Tsung
    Yeh, Chih-Kuang
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1635 - 1638
  • [38] The Effect of Tissue-Mimicking Phantom Compressibility on Magnetic Hyperthermia
    Kaczmarek, Katarzyna
    Mrowczynski, Radoslaw
    Hornowski, Tomasz
    Bielas, Rafal
    Jozefczak, Arkadiusz
    NANOMATERIALS, 2019, 9 (05)
  • [39] Evaluation of a tissue-mimicking thermochromic phantom for radiofrequency ablation
    Mikhail, Andrew S.
    Negussie, Ayele H.
    Graham, Cole
    Mathew, Manoj
    Wood, Bradford J.
    Partanen, Ari
    MEDICAL PHYSICS, 2016, 43 (07) : 4304 - 4311
  • [40] Simulation and Measurement of Thermal Ablation in a Tissue-Mimicking Phantom and Ex-Vivo Porcine Liver by Using High Intensity Focused Ultrasound
    Kang Il Lee
    Journal of the Korean Physical Society, 2018, 73 : 1289 - 1294