Comparison of single and multiple dwell position methods in MammoSite high dose rate (HDR) brachytherapy planning

被引:3
|
作者
Kim, Yongbok [1 ,2 ]
Trombetta, Mark G. [1 ,2 ]
Miften, Moyed [3 ]
机构
[1] Allegheny Gen Hosp, Dept Radiat Oncol, Pittsburgh, PA 15212 USA
[2] Drexel Univ, Coll Med, Pittsburgh, PA USA
[3] Univ Colorado Denver, Dept Radiat Oncol, Aurora, CO USA
来源
关键词
single and multiple dwell position methods; interfraction dose variation; MammoSite; HDR brachytherapy; APPLICATOR; OPTIMIZATION; IRRADIATION; INDEX;
D O I
10.1120/jacmp.v11i3.3235
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to dosimetrically compare two plans generated-using single dwell position method (SDPM) and multiple dwell position methods (MDPM) in MammoSite high dose rate (HDR) brachytherapy planning for 19 breast cancer patients. In computed tomography (CT) image-based HDR planning, a surface optimization technique was used in both methods. Following dosimetric parameters were compared for fraction 1 plans: %PTV_EVAL (planning target volume for plan evaluation) coverage, dose homogeneity index (DHI), dose conformal index (COIN), maximum dose to skin and ipsilateral lung, and breast tissue volume receiving 150% (V150[cc]) and 200% (V200[cc]) of the prescribed dose. In addition, a plan was retrospectively generated for each fraction 2-10 to simulate the clinical situation where the fraction 1 plan was used for fractions 2-10 without modification. In order to create nine derived plans for each method and for each of the 19 patients, the catheter location and contours of target and critical structures were defined on the CT images acquired prior to each fraction 2-10, while using the same dwell-time distribution as used for fraction 1 (original plan). Interfraction dose variations were evaluated for 19 patients by comparing the derived nine plans (each for fractions 2-10) with the original plan (fraction 1) using the same dosimetric parameters used for fraction 1 plan comparison. For the fraction 1 plan comparison, the MDPM resulted in slightly increased %PTV_EVAL coverage, COIN, V150[cc] and V200[cc] values by an average of 1.2%, 0.025, 0.5 cc and 0.7 cc, respectively, while slightly decreased DHI, maximum skin and ipsilateral lung dose by an average of 0.003, 3.2 cGy and 5.8 cGy, respectively. For the interfraction dose variation comparison, the SDPM resulted in slightly smaller variations in %PTV_EVAL coverage, DHI, maximum skin dose and V150[cc] values by an average of 0.4%, 0.0005, 0.5 cGy and 0.2 cc, respectively, while slightly higher average variations in COIN, maximum ipsilateral lung dose and V200[cc] values by 0.0028, 0.2 cGy and 0.2 cc, respectively. All differences were too small to be clinically significant. Compared to the MDPM, the SDPM combined with a surface optimization technique can generate a clinically comparable fraction 1 treatment plan with a similar interfraction dose variation if a single source is carefully positioned at the center of the balloon catheter.
引用
下载
收藏
页码:54 / 63
页数:10
相关论文
共 50 条
  • [31] Development of a Clinical Knowledge-Based Model for High Dose Rate (HDR) Prostate Brachytherapy Planning
    Plypoo, A.
    Roeske, J.
    Surucu, M.
    Solanki, A.
    Harkenrider, M.
    Kang, H.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [32] Comparison of dose prescription using single versus multiple reference points for MammoSite RTS treatment planning
    Havnen, A.
    King, J.
    Mirzaei, M.
    MEDICAL PHYSICS, 2006, 33 (06) : 2081 - 2081
  • [33] Evaluation of anatomy-based dwell position and inverse optimization in high-dose-rate brachytherapy of prostate cancer: a dosimetric comparison to a conventional cylindrical dwell position, geometric optimization, and dose-point optimization
    Yoshioka, Y
    Nishimura, T
    Kamata, M
    Harada, H
    Kanazawa, K
    Fuji, H
    Murayama, S
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 (03) : 311 - 317
  • [34] A Planning Study: Escalating the Single Fraction Monotherapy Dose for HDR Prostate Brachytherapy
    Sabondjian, Eric
    Sankreacha, Raxa
    Yuen, Jasper
    Rauth, Sarah
    MEDICAL PHYSICS, 2019, 46 (11) : 5378 - 5378
  • [35] High dose rate (HDR) brachytherapy for prostate cancer in the early stages
    Bobkov, M.
    ANNALS OF ONCOLOGY, 2016, 27
  • [36] Results of high dose rate (HDR) brachytherapy boost for prostate cancer
    Kelly, D
    Flynn, J
    Brookover, W
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S18 - S18
  • [37] Commissioning Integrated System in High-Dose-Rate (HDR) Brachytherapy
    Saw, C.
    Juliano, J.
    Wagner, H.
    MEDICAL PHYSICS, 2011, 38 (06) : 3516 - U64
  • [38] High dose rate (HDR) brachytherapy boost for prostate cancer gives high control rate
    Flynn, J. P.
    Kelly, D. A.
    Brookover, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S323 - S324
  • [39] Dosimetric Evaluation Of PLATO And ONCENTRA Treatment Planning Systems For High Dose Rate (HDR) Brachytherapy Gynecological Treatments
    Singh, Hardev
    Herman, Tania De La Fuente
    Showalter, Barry
    Thompson, Spencer J.
    Syzek, Elizabeth J.
    Herman, Terence
    Ahmad, Salahuddin
    MEDICAL PHYSICS, 2012, 1494 : 70 - 72
  • [40] Comparison of focal boost high dose rate prostate brachytherapy optimisation methods
    Mason, Josh
    Bownes, Peter
    Carey, Brendan
    Henry, Ann
    RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) : 521 - 524