Ferrocene-mediated carbon paste electrode modified with D-fructose dehydrogenase for batch mode measurement of D-fructose

被引:10
|
作者
Boujtita, M [1 ]
El Murr, N [1 ]
机构
[1] Fac Sci Tech, CNRS UPRSA 6006, Grp Electrochim, Lab Anal Isotop & Electrochim Metab, F-44322 Nantes 03, France
关键词
renewable surface electrode; modified carbon paste electrode; fructose dehydrogenase; fructose;
D O I
10.1385/ABAB:89:1:55
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A mediated modified carbon paste and renewable surface electrode for fructose amperometric measurement based on D-fructose dehydrogenase (FDH) was prepared and optimized. Commercially available ferrocene (FcH) and hydroxymethyl ferrocene (FcCH(2)OH) were used as mediators. The substituted FcH showed better linearity and higher sensitivity. The influence of different experimental parameters was studied for optimum analytical performance. The final FDH-modified electrode showed good analytical performance for batch mode measurements of fructose.
引用
收藏
页码:55 / 66
页数:12
相关论文
共 50 条
  • [1] Ferrocene-mediated carbon paste electrode modified with d-fructose dehydrogenase for batch mode measurement of d-fructose
    Mohamed Boujtita
    Nabil El Murr
    [J]. Applied Biochemistry and Biotechnology, 2000, 89 : 55 - 66
  • [2] D-FRUCTOSE DEHYDROGENASE-MODIFIED CARBON PASTE ELECTRODE CONTAINING PARA-BENZOQUINONE AS A MEDIATED AMPEROMETRIC FRUCTOSE SENSOR
    IKEDA, T
    MATSUSHITA, F
    SENDA, M
    [J]. AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1990, 54 (11): : 2919 - 2924
  • [3] D-fructose sensing electrode based on electron transfer of D-fructose dehydrogenase at colloidal gold-enzyme modified electrode
    Yabuki, S
    Mizutani, F
    [J]. ELECTROANALYSIS, 1997, 9 (01) : 23 - 25
  • [4] Amperometric mediated carbon paste biosensor based on D-fructose dehydrogenase for the determination of fructose in food analysis
    Paredes, PA
    Parellada, J
    Fernandez, VM
    Katakis, I
    Dominguez, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (12): : 1233 - 1243
  • [5] Coulometric D-Fructose Biosensor Based on Direct Electron Transfer Using D-Fructose Dehydrogenase
    Tsujimura, Seiya
    Nishina, Akiko
    Kamitaka, Yuji
    Kano, Kenji
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (22) : 9383 - 9387
  • [6] HYDROGENATION OF D-FRUCTOSE AND D-FRUCTOSE D-GLUCOSE MIXTURES
    MAKKEE, M
    KIEBOOM, APG
    VANBEKKUM, H
    [J]. CARBOHYDRATE RESEARCH, 1985, 138 (02) : 225 - 236
  • [7] Bioelectrocatalytic performance of D-fructose dehydrogenase
    Adachi, Taiki
    Kaida, Yuya
    Kitazumi, Yuki
    Shirai, Osamu
    Kano, Kenji
    [J]. BIOELECTROCHEMISTRY, 2019, 129 : 1 - 9
  • [8] DETERMINATION OF SEMINAL FRUCTOSE USING D-FRUCTOSE DEHYDROGENASE
    NAKASHIMA, K
    TAKEI, H
    ADACHI, O
    SHINAGAWA, E
    AMEYAMA, M
    [J]. CLINICA CHIMICA ACTA, 1985, 151 (03) : 307 - 310
  • [9] A NEW ENZYME D-FRUCTOSE DEHYDROGENASE
    YAMADA, Y
    AIDA, K
    UEMURA, T
    [J]. AGRICULTURAL AND BIOLOGICAL CHEMISTRY, 1966, 30 (01): : 95 - &
  • [10] D-FRUCTOSE DIHYDRATE
    YOUNG, FE
    JONES, FT
    LEWIS, HJ
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1952, 56 (06): : 738 - 739