Motion compensated whole-heart coronary cardiovascular magnetic resonance angiography using focused navigation (fNAV)

被引:20
|
作者
Roy, Christopher W. [1 ,2 ]
Heerfordt, John [1 ,2 ,3 ]
Piccini, Davide [1 ,2 ,3 ]
Rossi, Giulia [1 ,2 ]
Pavon, Anna Giulia [4 ]
Schwitter, Juerg [4 ,5 ,6 ]
Stuber, Matthias [1 ,2 ,7 ]
机构
[1] Lausanne Univ Hosp CHUV, Dept Radiol, Rue Bugnon 46,BH-7-84, CH-1011 Lausanne, Switzerland
[2] Univ Lausanne UNIL, Rue Bugnon 46,BH-7-84, CH-1011 Lausanne, Switzerland
[3] Siemens Healthcare AG, Adv Clin Imaging Technol ACIT, Lausanne, Switzerland
[4] Lausanne Univ Hosp CHUV, Div Cardiol, Lausanne, Switzerland
[5] Lausanne Univ Hosp CHUV, CMR Ctr, Lausanne, Switzerland
[6] Univ Lausanne UNIL, Fac Biol & Med, Lausanne, Switzerland
[7] Ctr Biomed Imaging CIBM, Lausanne, Switzerland
关键词
Coronary magnetic resonance angiography; Motion correction; Whole heart; Free-breathing;
D O I
10.1186/s12968-021-00717-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Radial self-navigated (RSN) whole-heart coronary cardiovascular magnetic resonance angiography (CCMRA) is a free-breathing technique that estimates and corrects for respiratory motion. However, RSN has been limited to a 1D rigid correction which is often insufficient for patients with complex respiratory patterns. The goal of this work is therefore to improve the robustness and quality of 3D radial CCMRA by incorporating both 3D motion information and nonrigid intra-acquisition correction of the data into a framework called focused navigation (fNAV) Methods:We applied fNAV to 500 data sets from a numerical simulation, 22 healthy subjects, and 549 cardiac patients. In each of these cohorts we compared fNAV to RSN and respiratory resolved extradimensional golden-angle radial sparse parallel (XD-GRASP) reconstructions of the same data. Reconstruction times for each method were recorded. Motion estimate accuracy was measured as the correlation between fNAV and ground truth for simulations, and fNAV and image registration for in vivo data. Percent vessel sharpness was measured in all simulated data sets and healthy subjects, and a subset of patients. Finally, subjective image quality analysis was performed by a blinded expert reviewer who chose the best image for each in vivo data set and scored on a Likert scale 0-4 in a subset of patients by two reviewers in consensus. Results:The reconstruction time for fNAV images was significantly higher than RSN (6.12.1 min vs 1.4 +/- 0.3, min, p<0.025) but significantly lower than XD-GRASP (25.6 +/- 7.1, min, p<0.025). Overall, there is high correlation between the fNAV and reference displacement estimates across all data sets (0.73 +/- 0.29). For simulated data, healthy subjects, and patients, fNAV lead to significantly sharper coronary arteries than all other reconstruction methods (p<0.01). Finally, in a blinded evaluation by an expert reviewer fNAV was chosen as the best image in 444 out of 571 data sets (78%; p< 0.001) and consensus grades of fNAV images (2.6 +/- 0.6) were significantly higher (p<0.05) than uncorrected (1.7 +/- 0.7), RSN (1.9 +/- 0.6), and XD-GRASP (1.8 +/- 0.8). Conclusion: fNAV is a promising technique for improving the quality of RSN free-breathing 3D whole-heart CCMRA. This novel approach to respiratory self-navigation can derive 3D nonrigid motion estimations from an acquired 1D signal yielding statistically significant improvement in image sharpness relative to 1D translational correction as well as XD-GRASP reconstructions. Further study of the diagnostic impact of this technique is therefore warranted to evaluate its full clinical utility.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Optimization of the acceleration of compressed sensing in whole-heart contrast-free coronary magnetic resonance angiography
    Wang, Weiwei
    Zhang, Longyan
    Su, Guangzong
    Xiong, Feng
    Wu, Yang
    Yu, Ke
    Yi, Qiaodan
    Sun, Peng
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2025, 27 (01)
  • [32] Evaluation of Cardiac Allograft Vasculopathy by Multidetector Computed Tomography and Whole-Heart Magnetic Resonance Coronary Angiography
    Nunoda, Shinichi
    Machida, Haruhiko
    Sekikawa, Akihiko
    Shitakura, Kazunobu
    Okajima, Kiyotaka
    Kubo, Yutaka
    Ueno, Eiko
    Otsuka, Kuniaki
    CIRCULATION JOURNAL, 2010, 74 (05) : 946 - 953
  • [33] Whole-Heart Coronary Angiography using Volume Computed Tomography in Comparison to Conventional Coronary Angiography
    Dewey, Marc
    Zimmermann, Elike
    Deissenrieder, Florian
    Laule, Michael
    Duebel, Hans-Peter
    Rutsch, Wolfgang
    Hamm, Bernd
    CIRCULATION, 2008, 118 (18) : S1006 - S1006
  • [34] Free-running cardiac and respiratory motion-resolved 5D whole-heart coronary cardiovascular magnetic resonance angiography in pediatric cardiac patients using ferumoxytol
    Roy, Christopher W.
    Di Sopra, Lorenzo
    Whitehead, Kevin K.
    Piccini, Davide
    Yerly, Jerome
    Heerfordt, John
    Ghosh, Reena M.
    Fogel, Mark A.
    Stuber, Matthias
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
  • [35] Free-running cardiac and respiratory motion-resolved 5D whole-heart coronary cardiovascular magnetic resonance angiography in pediatric cardiac patients using ferumoxytol
    Christopher W. Roy
    Lorenzo Di Sopra
    Kevin K. Whitehead
    Davide Piccini
    Jérôme Yerly
    John Heerfordt
    Reena M. Ghosh
    Mark A. Fogel
    Matthias Stuber
    Journal of Cardiovascular Magnetic Resonance, 24
  • [36] Contrast-Enhanced Whole-Heart Coronary Magnetic Resonance Angiography at 3 T Using Interleaved Echo Planar Imaging
    Bhat, Himanshu
    Yang, Qi
    Zuehlsdorff, Sven
    Li, Kuncheng
    Li, Debiao
    INVESTIGATIVE RADIOLOGY, 2010, 45 (08) : 458 - 464
  • [37] Whole-heart coronary MR angiography - Initial results
    Ozgun, M.
    Hoffmeier, A.
    Quante, M.
    Fischbach, R.
    Heindel, W.
    Botnar, R.
    Maintz, D.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2006, 178 (05): : 500 - 507
  • [38] 3.0-T whole-heart coronary magnetic resonance angiography: comparison of gadobenate dimeglumine and gadofosveset trisodium
    Fabio S. Raman
    Marcelo S. Nacif
    George Cater
    Neville Gai
    Jacquin Jones
    Debiao Li
    Christopher T. Sibley
    Songtao Liu
    David A. Bluemke
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1085 - 1094
  • [39] 210 Validation of a semi-automatic coronary vessel tracker algorithm for magnetic resonance whole-heart angiography
    Jeroen Sonnemans
    Raymond Habets
    Javier Olivan-Bescos
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [40] 3.0-T whole-heart coronary magnetic resonance angiography: comparison of gadobenate dimeglumine and gadofosveset trisodium
    Raman, Fabio S.
    Nacif, Marcelo S.
    Cater, George
    Gai, Neville
    Jones, Jacquin
    Li, Debiao
    Sibley, Christopher T.
    Liu, Songtao
    Bluemke, David A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (05): : 1085 - 1094