Robotics Versus Navigation Versus Conventional Total Hip Arthroplasty: Does the Use of Technology Yield Superior Outcomes?

被引:52
|
作者
Singh, Vivek [1 ]
Realyvasquez, John [1 ]
Simcox, Trevor [1 ]
Rozell, Joshua C. [1 ]
Schwarzkopf, Ran [1 ]
Davidovitch, Roy, I [1 ]
机构
[1] NYU Langone Hlth, Dept Orthoped Surg, New York, NY USA
来源
JOURNAL OF ARTHROPLASTY | 2021年 / 36卷 / 08期
关键词
technology; navigation; robotics; total hip arthroplasty; patient-reported outcome measures; outcomes; KNEE ARTHROPLASTY; IMAGELESS NAVIGATION; CUP PLACEMENT; COMORBIDITY; RISK; THA;
D O I
10.1016/j.arth.2021.02.074
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The use of technology such as navigation and robotic systems may improve the accuracy of component positioning in total hip arthroplasty (THA), but its impact on patient-reported outcome measures (PROMS) remains unclear. This study aims to elucidate the association between the use of intraoperative technology and PROMS in patients who underwent primary THA. Methods: We retrospectively reviewed a consecutive series of patients who underwent primary THA between 2016 and 2020 and answered PROM questionnaires. Patients were separated into 3 groups depending on intraoperative technology utilization: computer-assisted navigation, robotic-assisted, or no technology (conventional) THA. Forgotten Joint Score-12 and Hip disability and Osteoarthritis Outcome Score, Joint Replacemen scores were collected at various time points. Demographic differences were assessed with chi-square and analysis of variance. Mean scores between groups were compared using univariate analysis of covariance, controlling for all significant demographic differences. Results: Of the 1960 cases identified, 896 used navigation, 135 used robotics, and 929 used no technology. There were significant statistical differences in one-year Hip disability and Osteoarthritis Outcome Score, Joint Replacement scores (85.23 vs 85.95 vs 86.76, respectively; P = .014) and two-year Forgotten Joint Score-12 scores (64.72 vs 73.35 vs 74.63, respectively; P = .004) between the 3 groups. However, these differences did not exceed the mean clinically important differences. Length of stay was statistically longest for patients who underwent conventionally performed THA versus navigation and robotics (2.22 vs 1.46 vs 1.91, respectively; P < .001). Surgical time was significantly longer for cases performed using robotics versus navigation and conventionally (119.61 vs 90.35 vs 95.35, respectively; P < .001). Conclusion: Statistical differences observed between all modalities are not likely to be clinically meaningful with regard to early patient-reported outcomes. Although intraoperative use of technology may improve the accuracy of implant placement, these modalities have not yet translated into improved early reported functional outcomes. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页码:2801 / 2807
页数:7
相关论文
共 50 条
  • [31] Outcomes of acute versus delayed total hip arthroplasty following acetabular fracture
    G. Gracia
    P. Laumonerie
    M. E. Tibbo
    E. Cavaignac
    P. Chiron
    N. Reina
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 51 - 60
  • [32] A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty
    Mu, Zongyou
    Tian, Jialiang
    Wu, Taixiang
    Yang, Jing
    Pei, Fuxing
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) : 599 - 604
  • [33] A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty
    Zongyou Mu
    Jialiang Tian
    Taixiang Wu
    Jing Yang
    Fuxing Pei
    International Orthopaedics, 2009, 33 : 599 - 604
  • [34] Complication Rates of Hemiarthroplasty Conversion to Total Hip Arthroplasty Versus Primary Total Hip Arthroplasty
    Ofa, Sione A.
    Ross, Austin J.
    Ross, Bailey J.
    Lee, Oliva C.
    Sherman, William F.
    ORTHOPEDIC REVIEWS, 2021, 13 (02)
  • [35] Total hip arthroplasty versus hemiarthroplasty for intracapsular hip fracture
    Judge, A.
    Metcalfe, D.
    Whitehouse, M. R.
    Parsons, N.
    Costa, M.
    BONE & JOINT JOURNAL, 2020, 102B (06): : 658 - 660
  • [36] Total hip arthroplasty versus hemiarthroplasty for intracapsular hip fractures
    Parker, M.
    BONE & JOINT JOURNAL, 2021, 103B (01): : 3 - 4
  • [37] Changes in periacetabular bone mineral density five years after resurfacing hip arthroplasty versus conventional total hip arthroplasty
    Gerhardt, Davey M. J. M.
    Smolders, Jose M. H.
    Roovers, Elisabeth A.
    Rijnders, Ton A. J. M.
    van Susante, Job L. C.
    HIP INTERNATIONAL, 2019, 29 (02) : 153 - 160
  • [38] Readmission rate and healthcare utilization outcomes of computer-assisted fluoroscopy-based hip navigation versus manual total hip arthroplasty
    Hamilton, William G. G.
    Sershon, Robert A. A.
    Gupta, Anshu
    Goldstein, Laura
    Kabiri, Mina
    Holy, Chantal E. E.
    Diaz, Rodrigo
    EXPERT REVIEW OF MEDICAL DEVICES, 2023, 20 (09) : 779 - 789
  • [39] Use of Imageless Navigation in the Conversion of Hip Fusion to Total Hip Arthroplasty
    Kuzyk, Paul
    Gross, Allan
    Lamb, Iain R.
    Muir, Jeffrey M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [40] Measurement of polyethylene wear in total hip arthroplasty - Accuracy versus ease of use
    Kang, JS
    Park, SR
    Ebramzadeh, E
    Dorr, LD
    YONSEI MEDICAL JOURNAL, 2003, 44 (03) : 473 - 478