RR interval variability in the evaluation of ventricular tachycardia and effects of implantable cardioverter defibrillator therapy

被引:2
|
作者
Tsukahara, Keita [1 ]
Oginosawa, Yasushi [1 ]
Fujino, Yoshihisa [2 ]
Honda, Toshihiro [3 ]
Kikuchi, Kan [4 ]
Nozoe, Masatsugu [5 ]
Uchida, Takayuki [6 ]
Minamiguchi, Hitoshi [7 ]
Sonoda, Koichiro [8 ]
Ogawa, Masahiro [9 ]
Ideguchi, Takeshi [10 ]
Kizaki, Yoshihisa [11 ]
Nakamura, Toshihiro [12 ]
Oba, Kageyuki [13 ]
Higa, Satoshi [14 ]
Yoshida, Keiki [15 ]
Yagyu, Keishiro [1 ]
Miyamoto, Taro [1 ]
Yamagishi, Yasunobu [1 ]
Ohe, Hisaharu [1 ]
Kohno, Ritsuko [16 ]
Kataoka, Masaharu [1 ]
Otsuji, Yutaka [1 ]
Abe, Haruhiko [16 ]
机构
[1] Univ Occupat & Environm Hlth, Dept Internal Med 2, Kitakyushu, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Environm Epidmiol, Inst Ind Ecol Sci, Kitakyushu, Fukuoka, Japan
[3] Kumamoto Junkankika Hosp, Div Cardiol, Kumamoto, Japan
[4] Kyushu Hosp, Div Cardiol, Japan Community Healthcare Org, Kitakyushu, Japan
[5] Saiseikai Fukuoka Gen Hosp, Div Cardiol, Fukuoka, Japan
[6] Iizuka Hosp, Dept Cardiovasc Surg, Iizuka, Japan
[7] Osaka Police Hosp, Dept Cardiol, Osaka, Japan
[8] Sasebo City Gen Hosp, Dept Cardiol, Sasebo, Japan
[9] Fukuoka Univ, Dept Cardiol, Sch Med, Fukuoka, Japan
[10] Univ Miyazaki, Fac Med, Dept Internal Med, Circulatory & Body Fluid Regulat, Miyazaki, Japan
[11] Sasebo Chuo Hosp, Dept Cardiol, Nagasaki, Japan
[12] Natl Hosp Org, Dept Cardiol, Kyushu Med Ctr, Fukuoka, Japan
[13] Yuai Med Ctr, Dept Cardiol, Okinawa, Japan
[14] Makiminato Cent Hosp, Div Cardiovasc Med, Cardiac Elctrophysiol & Pacing Lab, Okinawa, Japan
[15] Saga Ken Med Ctr Koseikan, Dept Cardiol, Saga, Saga, Japan
[16] Univ Occupat & Environm Hlth, Dept Heart Rhythm Management, Kitakyushu, Japan
关键词
anti-tachycardia pacing therapy; implantable cardioverter defibrillator; RR interval variability; shock therapy; ventricular tachycardia; ANTITACHYCARDIA PACING THERAPIES; REDUCTION; SHOCKS; TACHYARRHYTHMIAS;
D O I
10.1002/joa3.12551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: An implantable cardioverter defibrillator (ICD) is the most reliable therapeutic device for preventing sudden cardiac death in patients with sustained ventricular tachycardia (VT). Regarding its effectiveness, targeted VT is defined based on the tachyarrhythmia cycle length. However, variations in RR interval variability of VTs may occur. Few studies have reported on VT characteristics and effects of ICD therapy according to the RR interval variability. We aimed to identify the clinical characteristics of VTs and ICD therapy effects according to the RR interval variability. Methods: We analyzed 821 VT episodes in 69 patients with ICDs or cardiac resynchronization therapy defibrillators. VTs were classified as irregular when the difference between two successive beats was >20 ms in at least one of 10 RR intervals; otherwise, they were classified as regular. We evaluated successful termination using anti-tachycardia pacing (ATP)/shock therapy, spontaneous termination, and acceleration between regular and irregular VTs. The RR interval variability reproducibility rates were evaluated. Results: Regular VT was significantly more successfully terminated than irregular VT by ATP. No significant difference was found in shock therapy or VT acceleration between the regular and irregular VTs. Spontaneous termination occurred significantly more often in irregular than in regular VT cases. The reproducibility rates of RR interval variability in each episode and in all episodes were 89% and 73%, respectively. Conclusions: ATP therapy showed greater effectiveness for regular than for irregular VT. Spontaneous termination was more common in irregular than in regular VT. RR interval variability of VTs seems to be reproducible.
引用
收藏
页码:1052 / 1060
页数:9
相关论文
共 50 条
  • [11] Sexual activity as a trigger for ventricular tachycardia in a patient with implantable cardioverter defibrillator
    Safi, AM
    Rachko, M
    Yeshou, D
    Stein, RA
    ARCHIVES OF SEXUAL BEHAVIOR, 2002, 31 (03) : 295 - 299
  • [12] Long-term Arrhythmia Variability after Monomorphic Ventricular Tachycardia in Patients with an Implantable Cardioverter Defibrillator
    Clemens, Marcell
    Nagy-Balo, Edina
    Herczku, Csaba
    Kun, Csaba
    Edes, Istvan
    Csanadi, Zoltan
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (10): : 1185 - 1191
  • [13] Implantable cardioverter-defibrillator therapy in patients with nonischemic ventricular tachycardia or -fibrillation and normal left ventricular function
    Wichter, T
    Block, M
    MartinezRubio, A
    Brunn, J
    Weber, M
    Bansch, D
    Borggrefe, M
    CIRCULATION, 1996, 94 (08) : 763 - 763
  • [14] Implantable cardioverter defibrillator therapy in patients with ischemic or non-ischemic cardiomyopathy and nonsustained ventricular tachycardia
    Evonich, RF
    Maheshwari, A
    Gardiner, JC
    Khasnis, A
    Kantipudi, S
    Ip, JH
    Grimes, D
    Hayter, G
    Thakur, RK
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2004, 11 (01) : 59 - 65
  • [15] Implantable cardioverter defibrillator detection during radiofrequency catheter ablation of ventricular tachycardia
    Hammerschmidt, S
    Cao, KJ
    Schaumann, A
    Krieglstein, H
    Gonska, BD
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (09): : 1388 - 1390
  • [16] Increase in ventricular tachycardia frequency after biventricular implantable cardioverter defibrillator upgrade
    Guerra, JM
    Wu, JY
    Miller, JM
    Groh, WJ
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (11) : 1245 - 1247
  • [17] COMBINATION OF ANTITACHYCARDIA PACEMAKER AND AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR FOR VENTRICULAR-TACHYCARDIA
    MANZ, M
    GERCKENS, U
    FUNKE, HD
    KIRCHHOFF, PG
    LUDERITZ, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (05): : 676 - 684
  • [18] Implantable Cardioverter Defibrillator Therapy in Patients with Ischemic or Non-Ischemic Cardiomyopathy and Nonsustained Ventricular Tachycardia
    Rudolph F. Evonich
    Alok Maheshwari
    Joseph C. Gardiner
    Atul Khasnis
    Sricharan Kantipudi
    John H. Ip
    Denise Grimes
    Gregory Hayter
    Ranjan K. Thakur
    Journal of Interventional Cardiac Electrophysiology, 2004, 11 : 59 - 65
  • [19] Supraventricular arrhythmias and implantable cardioverter defibrillator shocks in catecholaminergic polymorphic ventricular tachycardia
    Dusi, V.
    De Ferrari, G. M.
    Bos, J. M.
    Moir, C. R.
    Shkolnikova, M.
    Abrams, D. J.
    Crotti, L.
    Wilde, A. A. M.
    Paul, T.
    Eldar, M.
    Till, J.
    Noguer, F. R. I.
    Krahn, A. D.
    Schwartz, P. J.
    Ackerman, M. J.
    EUROPEAN HEART JOURNAL, 2016, 37 : 83 - 83
  • [20] Ventricular tachycardia initiated by high energy cardioversion in a patient with an implantable cardioverter defibrillator
    Chinushi, M
    Aizawa, Y
    Higuchi, K
    HEART, 1997, 77 (04) : 373 - 374