RR interval variability in the evaluation of ventricular tachycardia and effects of implantable cardioverter defibrillator therapy

被引:2
|
作者
Tsukahara, Keita [1 ]
Oginosawa, Yasushi [1 ]
Fujino, Yoshihisa [2 ]
Honda, Toshihiro [3 ]
Kikuchi, Kan [4 ]
Nozoe, Masatsugu [5 ]
Uchida, Takayuki [6 ]
Minamiguchi, Hitoshi [7 ]
Sonoda, Koichiro [8 ]
Ogawa, Masahiro [9 ]
Ideguchi, Takeshi [10 ]
Kizaki, Yoshihisa [11 ]
Nakamura, Toshihiro [12 ]
Oba, Kageyuki [13 ]
Higa, Satoshi [14 ]
Yoshida, Keiki [15 ]
Yagyu, Keishiro [1 ]
Miyamoto, Taro [1 ]
Yamagishi, Yasunobu [1 ]
Ohe, Hisaharu [1 ]
Kohno, Ritsuko [16 ]
Kataoka, Masaharu [1 ]
Otsuji, Yutaka [1 ]
Abe, Haruhiko [16 ]
机构
[1] Univ Occupat & Environm Hlth, Dept Internal Med 2, Kitakyushu, Fukuoka, Japan
[2] Univ Occupat & Environm Hlth, Dept Environm Epidmiol, Inst Ind Ecol Sci, Kitakyushu, Fukuoka, Japan
[3] Kumamoto Junkankika Hosp, Div Cardiol, Kumamoto, Japan
[4] Kyushu Hosp, Div Cardiol, Japan Community Healthcare Org, Kitakyushu, Japan
[5] Saiseikai Fukuoka Gen Hosp, Div Cardiol, Fukuoka, Japan
[6] Iizuka Hosp, Dept Cardiovasc Surg, Iizuka, Japan
[7] Osaka Police Hosp, Dept Cardiol, Osaka, Japan
[8] Sasebo City Gen Hosp, Dept Cardiol, Sasebo, Japan
[9] Fukuoka Univ, Dept Cardiol, Sch Med, Fukuoka, Japan
[10] Univ Miyazaki, Fac Med, Dept Internal Med, Circulatory & Body Fluid Regulat, Miyazaki, Japan
[11] Sasebo Chuo Hosp, Dept Cardiol, Nagasaki, Japan
[12] Natl Hosp Org, Dept Cardiol, Kyushu Med Ctr, Fukuoka, Japan
[13] Yuai Med Ctr, Dept Cardiol, Okinawa, Japan
[14] Makiminato Cent Hosp, Div Cardiovasc Med, Cardiac Elctrophysiol & Pacing Lab, Okinawa, Japan
[15] Saga Ken Med Ctr Koseikan, Dept Cardiol, Saga, Saga, Japan
[16] Univ Occupat & Environm Hlth, Dept Heart Rhythm Management, Kitakyushu, Japan
关键词
anti-tachycardia pacing therapy; implantable cardioverter defibrillator; RR interval variability; shock therapy; ventricular tachycardia; ANTITACHYCARDIA PACING THERAPIES; REDUCTION; SHOCKS; TACHYARRHYTHMIAS;
D O I
10.1002/joa3.12551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: An implantable cardioverter defibrillator (ICD) is the most reliable therapeutic device for preventing sudden cardiac death in patients with sustained ventricular tachycardia (VT). Regarding its effectiveness, targeted VT is defined based on the tachyarrhythmia cycle length. However, variations in RR interval variability of VTs may occur. Few studies have reported on VT characteristics and effects of ICD therapy according to the RR interval variability. We aimed to identify the clinical characteristics of VTs and ICD therapy effects according to the RR interval variability. Methods: We analyzed 821 VT episodes in 69 patients with ICDs or cardiac resynchronization therapy defibrillators. VTs were classified as irregular when the difference between two successive beats was >20 ms in at least one of 10 RR intervals; otherwise, they were classified as regular. We evaluated successful termination using anti-tachycardia pacing (ATP)/shock therapy, spontaneous termination, and acceleration between regular and irregular VTs. The RR interval variability reproducibility rates were evaluated. Results: Regular VT was significantly more successfully terminated than irregular VT by ATP. No significant difference was found in shock therapy or VT acceleration between the regular and irregular VTs. Spontaneous termination occurred significantly more often in irregular than in regular VT cases. The reproducibility rates of RR interval variability in each episode and in all episodes were 89% and 73%, respectively. Conclusions: ATP therapy showed greater effectiveness for regular than for irregular VT. Spontaneous termination was more common in irregular than in regular VT. RR interval variability of VTs seems to be reproducible.
引用
收藏
页码:1052 / 1060
页数:9
相关论文
共 50 条
  • [1] Inappropriate implantable cardioverter defibrillator therapy: RR interval stability does not discriminate between atrial fibrillation and ventricular tachycardia
    Nanthakumar, K
    Newman, DM
    Paquette, M
    Gilkerson, JD
    Guidant, CPI
    Greene, M
    Szpak, C
    Dorian, P
    CIRCULATION, 1998, 98 (17) : 712 - 712
  • [2] IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IN CATECHOLAMINERGIC POLYMORPHIC VENTRICULAR TACHYCARDIA
    Wanguemert Perez, Fernando
    Ruiz Hernandez, Pablo
    Perez, Guillermo
    Campuzano Larrea, Oscar
    Hernandez, Julio
    Brugada, Josep
    Brugada, Ramon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 818 - 818
  • [3] Failure of an Implantable Cardioverter Defibrillator to Terminate Ventricular Tachycardia: Why?
    Conti, Letizia
    Tran, Nam
    Burri, Haran
    Zimmermann, Marc
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (02): : 228 - 230
  • [4] PROVOCATION OF VENTRICULAR-TACHYCARDIA BY AN AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    KOU, WH
    KIRSH, MM
    STIRLING, MC
    KADISH, AH
    ORRINGER, CE
    MORADY, F
    AMERICAN HEART JOURNAL, 1990, 120 (01) : 208 - 210
  • [5] Implantable cardioverter defibrillator therapy for ambulatory ventricular tachycardia: Are we using an elephant gun?
    Kadish, AH
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2004, 15 (06) : 665 - 666
  • [6] ANTITACHYCARDIA PACEMAKER AND AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR AS SOLE THERAPY FOR VENTRICULAR-TACHYCARDIA
    MALONEY, JD
    MASTERSON, M
    WILKOFF, B
    SIMMONS, T
    MORANT, VA
    CASTLE, LW
    GOLDING, L
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A140 - A140
  • [7] Heart rate variability patterns before ventricular tachycardia onset in patients with as implantable cardioverter defibrillator
    Lombardi, F
    Porta, A
    Marzegalli, M
    Favale, S
    Santini, M
    Vincenti, A
    De Rosa, A
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 86 (09): : 959 - 963
  • [8] Sexual Activity as a Trigger for Ventricular Tachycardia in a Patient with Implantable Cardioverter Defibrillator
    Arshad M. Safi
    Maurice Rachko
    Dima Yeshou
    Richard A. Stein
    Archives of Sexual Behavior, 2002, 31 : 295 - 299
  • [9] Fast ventricular tachycardia induced by programmed stimulation predicts appropriate implantable cardioverter defibrillator therapy
    Tiongson, J
    Robin, J
    Ciaccio, C
    Weinberg, K
    Goldberger, J
    Passman, R
    CIRCULATION, 2004, 110 (17) : 504 - 504
  • [10] RIGHT VENTRICULAR PACING AND IMPLANTABLE CARDIOVERTER DEFIBRILLATOR THERAPY
    Seifer, C.
    Farag, A.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (10) : S194 - S194