Fluid composition influences wear testing of artificial knee implants

被引:0
|
作者
Schwenke, T. [1 ]
Wimmer, M. A. [1 ]
Kaddick, C. [1 ]
机构
[1] Rush Univ, Med Ctr, Chicago, IL 60612 USA
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multi-axial simulator testing is a standard tool in development and evaluation of artificial hip and knee joints. Close to in-vivo conditions are desirable in terms of implant set-up, input parameters, and environment. Thus, specimens are subjected to loads and displacements measured for patients with artificial joints, and a lubrication medium is provided to simulate human synovial fluid. Implant wear is then commonly assessed through periodic gravimetric measurements. However, ultra-high weight polyethylene (UHMWPE), the typical material for tibial plateaus, has been shown to gain weight through fluid absorption, which influences the results of such tests. A recent study performed on a 4-DOF knee joint simulator reveals that composition variations in the lubricating medium highly influences fluid uptake of UHMWPE, and alters the wear behavior of tested specimen. Two lubricants, both within boundaries of ISO and ASTM testing standards but with different compositions, have been compared. They showed significant deviations in fluid soak and wear results. It is suggested that wear measurements are only comparable if testing parameters are kept in very tight tolerances and identical lubrication media are used.
引用
收藏
页码:173 / 177
页数:5
相关论文
共 50 条
  • [1] Wear and Creep Behavior of Total Knee Implants Undergoing Wear Testing
    Teeter, Matthew G.
    Parikh, Amit
    Taylor, Marc
    Sprague, Jeff
    Naudie, Douglas D.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (01): : 130 - 134
  • [2] Fluid composition impacts standardized testing protocols in ultrahigh molecular weight polyethylene knee wear testing
    Schwenke, T
    Kaddick, C
    Schneider, E
    Wimmer, MA
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2005, 219 (H6) : 457 - 464
  • [3] Synovial Fluid Replication in Knee Wear Testing: An Investigation of the Fluid Volume
    Reinders, Joern
    Sonntag, Robert
    Kretzer, Jan Philippe
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (01) : 92 - 97
  • [4] Review of the Artificial Hip and Knee Wear Testing Standards and Simulation Testing Machines
    Cui W.
    Zhang Y.
    Wang Z.
    Zeng H.
    Wu D.
    Jin Z.
    Mocaxue Xuebao/Tribology, 2019, 39 (02): : 248 - 258
  • [5] Prediction of wear in total knee replacement implants using artificial neural network
    Kumar, Vipin
    Rawat, Anubhav
    Tewari, R. P.
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2023, 43 (04) : 338 - 358
  • [6] In Vitro Wear Behavior of Knee Implants at Different Load Levels: The Impact of the Test Fluid
    Schroeder, Stefan
    Uhler, Maximilian
    Schonhoff, Mareike
    Nees, Timo A.
    Wonerow, Tanja
    Nuppnau, Jens
    Mantwill, Frank
    Kretzer, Jan Philippe
    LUBRICANTS, 2023, 11 (11)
  • [7] THEORETICAL AND EXPERIMENTAL INVESTIGATION ON CROSS-SHEAR DEPENDENCY OF POLYETHYLENE WEAR IN ARTIFICIAL KNEE IMPLANTS
    Schwenke, Thorsten
    Wimmer, Markus A.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 817 - 818
  • [8] Protocol for clinically-relevant and severe wear simulator testing of total hip and knee implants
    Widding, K
    Scott, M
    Jani, S
    Good, V
    Hunter, G
    Salehi, A
    TRIBOLOGY IN ENVIRONMENTAL DESIGN 2003, 2003, : 247 - 253
  • [9] Wear of polyethylene in artificial knee joints
    Fisher, J
    McEwen, HMJ
    Barnett, PI
    Bell, CJ
    Stewart, TD
    Stone, MH
    Ingham, E
    CURRENT ORTHOPAEDICS, 2001, 15 (06): : 399 - 405
  • [10] Development of a synovial fluid analogue with bio-relevant rheology for wear testing of orthopaedic implants
    Smith, Alan M.
    Fleming, Leigh
    Wudebwe, Uchena
    Bowen, James
    Grover, Liam M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 32 : 177 - 184