Arthroscopic all-inside repair using the meniscus arrow: Long-term clinical follow-up of 113 patients

被引:53
|
作者
Siebold, Rainer [1 ]
Dehler, Carsten [1 ]
Boes, Ludwig [1 ]
Ellermann, Andree [1 ]
机构
[1] ARCUS Sportklin, Dept Orthopaed, D-75179 Pforzheim, Germany
来源
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY | 2007年 / 23卷 / 04期
关键词
meniscus; repair; meniscus arrow; failure rate;
D O I
10.1016/j.arthro.2006.11.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: A clinical trial was carried out to investigate the long-term outcome of Meniscus Arrow (Bionx Implants, Blue Bell, PA) repair. Methods: In a case series 113 consecutive patients with an arthroscopic all-inside Meniscus Arrow repair were evaluated. The mean age was 30 years, and the mean length of follow-up was 6 years. Of the patients, 84% were available for follow-up. Repairs were performed in either the medial (81%) or lateral (19%) posterior horn in only the red-red or red-white meniscal zone. Concomitant anterior cruciate ligament reconstruction was performed in 66% of patients. Results: Of the patients, 28% showed a retear of the meniscus and had to undergo arthroscopic revision with partial meniscectomy. Simultaneous anterior cruciate ligament reconstruction had no significant influence on the revision rate. In patients who did not undergo revision, the mean Lysholm score was 91 points and the mean Cincinnati knee score was 93 points. The International Knee Documentation Committee classification was A or B in 90% of patients and C in 10%. At revision surgery, 2 patients showed distinct femoral cartilage damage caused by the head of the Meniscus Arrow. Conclusions: The Meniscus Arrow shows a high clinical failure rate of 28.4%, especially given that the use of the device was restricted to tears in the red-red and red-white zone of the meniscus, which would be expected to have a good heating potential. More than 80% of all failures occurred during the first 3 postoperative years, suggesting that the initial refixation potential of the Meniscus Arrow is low. Device-specific complications required additional operative treatment. Level of Evidence: Level IV, therapeutic case series.
引用
收藏
页码:394 / 399
页数:6
相关论文
共 50 条
  • [21] Outcomes of Arthroscopic All-Inside Repair vs Observation in Older Patients With Meniscus Root Tears: Response
    Dragoo, Jason L.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2020, 48 (11): : NP50 - NP51
  • [22] Posterolateral approach for all-inside arthroscopic lateral meniscus repair in athletes: technique and outcomes
    Mathieu Thaunat
    Pramod S. Ingale
    Thais Dutra Vieira
    Gaspard Auboyneau
    Abid Ghazi
    Bertrand Sonnery-Cottet
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1101 - 1108
  • [23] All-Inside Arthroscopic Tie-Grip Suture Repair for Radial Tear in the Midbody of Lateral Meniscus Using an All-Inside Device and Slotted Cannula
    Iguchi, Masaki
    Takahashi, Tsuneari
    Handa, Mikiko
    Takeshita, Katsushi
    ARTHROSCOPY TECHNIQUES, 2024, 13 (12):
  • [24] Arthroscopic all-inside repair for a tear of posterior root of the medial meniscus: a technical note
    Choi, Nam-Hong
    Son, Kyung-Mo
    Victoroff, Brian N.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (09) : 891 - 893
  • [25] Posterolateral approach for all-inside arthroscopic lateral meniscus repair in athletes: technique and outcomes
    Thaunat, Mathieu
    Ingale, Pramod S.
    Vieira, Thais Dutra
    Auboyneau, Gaspard
    Ghazi, Abid
    Sonnery-Cottet, Bertrand
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (07) : 1101 - 1108
  • [26] Arthroscopic all-inside repair for a tear of posterior root of the medial meniscus: a technical note
    Nam-Hong Choi
    Kyung-Mo Son
    Brian N. Victoroff
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 891 - 893
  • [27] Long-term outcome after all-inside meniscal repair using the RapidLoc system
    Solheim, Eirik
    Hegna, Janne
    Inderhaug, Eivind
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (05) : 1495 - 1500
  • [28] Long-term outcome after all-inside meniscal repair using the RapidLoc system
    Eirik Solheim
    Janne Hegna
    Eivind Inderhaug
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 1495 - 1500
  • [29] Long-term assessment of arthroscopic meniscus repair
    Steenbrugge, F
    Corteel, J
    Verdonk, R
    Verstraete, K
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2003, 89 (08): : 699 - 706
  • [30] "Zip" Lesion of the Lateral Meniscus Repair Technique Using All-Inside Meniscus Repair Device
    Pimprikar, Milind, V
    Patil, Hitendra G.
    ARTHROSCOPY TECHNIQUES, 2025, 14 (02):