Use of intravascular ultrasound as a "Quality Control" technique during carotid stent-angioplasty: are there risks to its use?

被引:0
|
作者
Bandyk, D. F. [1 ]
Armstrong, P. A. [1 ]
机构
[1] Univ S Florida, Coll Med, Div Vasc & Endovasc Surg, Tampa, FL USA
来源
JOURNAL OF CARDIOVASCULAR SURGERY | 2009年 / 50卷 / 06期
关键词
Stems; Angioplasty; Quality control; RESTENOSIS; PREDICTORS;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular ultrasound (IVUS) provides high-resolution vessel imaging and has been shown to improve clinical outcomes when used to assess the technical result of peripheral angioplasty procedures. Our vascular group compared anatomic and clinical outcomes of carotid artery stent-angioplasty (CAS) performed with angiogram monitoring alone, or in combination with IVUS imaging to select stent/balloon diameter and interrogate stent deployment region for residual stenosis. A retrospective review of our carotid stent registry (N=306) identified 220 AS procedures performed with either a digital C-arm fluoroscopy alone (N=110) or in conjunction with IVUS (N=110) with at least 6-month of clinical follow-up. Outcome measures of procedure time, angioplasty balloon diameter, contrast dye volume, Duplex surveillance testing for recurrent stenosis, and procedure event (death, cardiac, neurologic) rates were compared to assess the risks and benefits of IVUS. All procedures utilized a cerebral protection device deployed prior to IVUS imaging. Procedure times were similar, but IVUS usage resulted in lower (P<0.05) contrast agent volumes due to fewer angiogram runs for stent sizing and verification of adequate stent deployment. IVUS imaging resulted in the use of larger diameter balloons (typically 6 mm) for final stent angioplasty based on distal internal carotid artery (ICA) dia measurements, and identified (P<0.01) more residual stent abnormalities (N=12, 11%) versus CAS with angiogram assessment alone (N=2, 1.8%). No procedural or 30-day cardiac events or deaths occurred. The overall stroke rate was 0.9%; two events (stroke-1; reperfusion injury-1) in the angio+IVUS group (1.8%) and none in the angio alone group. Duplex ultrasound surveillance following CAS demonstrated a higher (P<0.01) incidence of >50% diameter-reducing in-stent stenosis in the angio alone group (11% vs 7% at 1 month; 24% vs 6% at last surveillance; mean 36 moontha; range: 6-66 months). The quality control of the CAS procedure was enhanced by IVUS imaging which directed stent/balloon sizing and was more accurate than angiography in confirming adequate stent expansion. No IVUS related adverse events occurred. Based on the anatomic information provided by IVUS, larger diameter angioplasty balloons were used which correlated with less residual stenosis after CAS based on duplex ultrasound testing.
引用
收藏
页码:727 / 733
页数:7
相关论文
共 50 条
  • [21] The use of intravascular ultrasound for intraoperative assessment during semiclosed thromboendarterectomy
    Vogt, KC
    Sillesen, H
    Schroeder, TV
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (01): : 21 - 25
  • [22] The Effect of Statin Use on Embolic Potential During Carotid Angioplasty and Stenting
    Tadros, Rami O.
    Vouyouka, Ageliki G.
    Chung, Christine
    Malik, Rajesh K.
    Krishnan, Prakash
    Ellozy, Sharif H.
    Marin, Michael L.
    Faries, Peter L.
    [J]. ANNALS OF VASCULAR SURGERY, 2013, 27 (01) : 96 - 103
  • [23] Combined use of optical coherence tomography and intravascular ultrasound imaging for the evaluation of stent thrombosis
    Gonzalo, Nieves
    Alfonso, Fernando
    Escaned, Javier
    [J]. EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (01) : 5 - 7
  • [24] Intravascular ultrasound assessment of the mechanism of lumen enlargement during cutting balloon angioplasty treatment of in-stent restenosis
    Ahmed, JM
    Mintz, GS
    Castagna, M
    Weissman, NJ
    Pichard, AD
    Satler, LF
    Kent, KM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (09): : 1032 - +
  • [25] The use of intravascular ultrasound as control procedure for the deployment of endovascular stented grafts
    Vogt, KC
    Brunkwall, J
    Malina, M
    Ivancev, K
    Lindblad, B
    Risberg, B
    Schroeder, TV
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1997, 13 (06) : 592 - 596
  • [26] USE OF AN INTRACORONARY STENT TO CONTROL INTRAPERICARDIAL BLEEDING DURING CORONARY-ARTERY RUPTURE COMPLICATING CORONARY ANGIOPLASTY
    THOMAS, MR
    WAINWRIGHT, RJ
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (02): : 169 - 172
  • [27] QUALITY CONTROL - ITS USE AND ABUSE
    GILMORE, F
    [J]. JOURNAL OF THE PATENT OFFICE SOCIETY, 1966, 48 (09): : 579 - 593
  • [28] Combined use of intravascular ultrasound and optical coherence tomography in patients suffering from stent thrombosis
    Alfonso Manterola, F.
    Dutary, J.
    Gonzalo, N.
    Jimenez-Quevedo, P.
    Paulo, M.
    Banuelos, C.
    Escaned, J.
    Perez-Vizcayno, M. J.
    Hernandez, R.
    Macaya, C.
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 : 863 - 863
  • [29] Ischemic preconditioning during the use of the PercuSurge occlusion balloon for carotid angioplasty and stenting
    Faries, Peter L.
    DeRubertis, Brian
    Trocciola, Susan
    Karwowski, John
    Kent, K. Craig
    Chaer, Rabih A.
    [J]. VASCULAR, 2008, 16 (01) : 1 - 9
  • [30] Iatrogenic Acute Coronary Dissection During Coronary Angioplasty for In-Stent Restenosis: Role of Intravascular Ultrasound in Diagnosis and Treatment
    Park, Chang-Bum
    Park, Hoon-Ki
    Kim, Chong-Jin
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (01): : E1 - E2