Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes

被引:85
|
作者
Abitbol, Olivia [1 ,2 ,3 ]
Bouden, Jihene [2 ,3 ]
Doan, Serge [2 ,3 ]
Hoang-Xuan, Thanh [2 ,3 ]
Gatinel, Damien [2 ,3 ]
机构
[1] St Joseph Fdn, Glaucoma Inst, Dept Ophthalmol, F-75674 Paris 14, France
[2] Hop Bichat Claude Bernard, Dept Ophthalmol, F-75877 Paris 18, France
[3] Rothschild Fdn, Dept Ophthalmol, Paris, France
关键词
central corneal thickness; corneal biomechanics; glaucoma; hysteresis; INTRAOCULAR-PRESSURE; BIOMECHANICAL PROPERTIES; ACQUIRED PIT; OPTIC-NERVE; RISK-FACTOR; THICKNESS; HYPERTENSION; DAMAGE;
D O I
10.1111/j.1755-3768.2009.01554.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To identify differences in corneal hysteresis (CH) and central corneal thickness (CCT) between healthy and glaucomatous patients. Methods: Retrospective observational study. One hundred and thirty-three eyes of 75 healthy and 58 glaucomatous patients were included. CH was measured in each patient using Ocular Response Analyzer. CCT was determined by ultrasonic pachymetry. For each patient, one eye was randomly selected. We used a Student t-test to search for significant differences between the different groups (p < 0.05). Results: In healthy and glaucomatous eyes, mean CH values were 10.46 +/- 1.6 and 8.77 +/- 1.4 mm Hg, respectively. Mean CCT values were 560.2 +/- 36.3 and 535.3 +/- 42.7 mu m, respectively. CH and CCT were significantly lower in glaucomatous eyes than in normal eyes, (p < 0.05). Discussion: In our series, CH was lower in glaucomatous than in normal eyes. The relationship between glaucoma, IOP, and ocular structures may not be confined to the consideration of CCT. A low CH value could be responsible for under-estimation of IOP. CH could also be a risk factor for glaucoma, independent of IOP. Further studies are needed to support these hypotheses. Conclusion: In our investigation, CCT and CH were significantly lower in glaucomatous eyes than in healthy eyes.
引用
收藏
页码:116 / 119
页数:4
相关论文
共 50 条
  • [41] Relationship between corneal hysteresis (CH) as measured by ocular response analyzer (ORA) and corneal central thickness (CCT) as determined using Pentacam in childhood glaucoma (CG) patients
    Perucho Gonzalez, Lucia
    Saenz-Frances, Federico
    Morales Fernendez, Laura
    Mendez-Hernandez, Carmen
    Martinez de la Casa, Jose Maria
    Perez Bartolome, Francisco
    Santos Bueso, Enrique
    Garcia Feijoo, Julian
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [42] Relative utility of central corneal thickness and corneal hysteresis for differentiating glaucomatous from glaucoma suspect eyes
    Pensyl, Denise
    Katiyar, Suchitra
    Sullivan-Mee, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [43] Correlations between corneal biomechanical properties measured with the Ocular Response Analyzer and ICare rebound tonometry
    Martins Jorge, Jorge Manuel
    Gonzalez-Meijome, Jose M.
    Queiros, Antonio
    Fernandes, Paulo
    Parafita, Manuel A.
    JOURNAL OF GLAUCOMA, 2008, 17 (06) : 442 - 448
  • [44] Fluctuations of the Ocular Response Analyzer in measuring Corneal Hysteresis of subjects with and without Glaucoma and other Systemic Conditions
    Chandrasekaran, Subhashini
    Uppuluri, Siri
    Sadek, Hadeel
    Lu, Ziyao
    Khouri, Albert S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [45] CORNEAL ELASTICITY AND OCULAR RIGIDITY IN NORMAL AND KERATOCONIC EYES
    EDMUND, C
    ACTA OPHTHALMOLOGICA, 1988, 66 (02): : 134 - 140
  • [46] Evaluation of the Ocular Response Analyzer in ocular hypertension, glaucoma, and normal populations. Prospective study on 329 eyes
    Streho, M.
    Dariel, R.
    Giraud, J. -M.
    Verret, C.
    Fenolland, J. -R.
    Crochelet, O.
    May, F.
    Maurin, J. -F.
    Renard, J. -P.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2008, 31 (10): : 953 - 960
  • [47] Diurnal Variation in Intraocular Pressure and Corneal Biomechanical Properties Measured by Ocular Response Analyzer in Normal and Nromal tension glaucoma Group in Korea
    Choi, Yeun Jung
    Rhew, Jin Young
    Choi, Kyu-Ryong
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [48] Corneal Biomechanical Properties in Myopic Eyes Measured by a Dynamic Scheimpflug Analyzer
    Wang, Jingyi
    Li, Ying
    Jin, Yumei
    Yang, Xue
    Zhao, Chan
    Long, Qin
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [49] The Dynamic Response of Intraocular Pressure and Ocular Pulse Amplitude to Acute Hemodynamic Changes in Normal and Glaucomatous Eyes
    Li, Jonathan C.
    Gupta, Vivek K.
    You, Yuyi
    Ng, Keith W.
    Graham, Stuart L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (10) : 6960 - 6967
  • [50] Association between Corneal Biomechanical Properties with Ocular Response Analyzer and Also CorvisST Tonometry, and Glaucomatous Visual Field Severity
    Hirasawa, Kazunori
    Matsuura, Masato
    Murata, Hiroshi
    Nakakura, Shunsuke
    Nakao, Yoshitaka
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2017, 6 (03):