Intermediate analysis of magnesium alloy covered stent for a lateral aneurysm model in the rabbit common carotid artery

被引:5
|
作者
Cui, Hong-kai [1 ,2 ]
Li, Fen-Bao [1 ,2 ]
Guo, Ying-Chang [1 ,2 ]
Zhao, Yong-Li [1 ,2 ]
Yan, Rui-Fang [1 ,2 ]
Wang, Wu [3 ,4 ]
Li, Yong-Dong [1 ,2 ,3 ,4 ]
Wang, Yong-Li [3 ,5 ]
Yuan, Guang-Yin [6 ,7 ,8 ]
机构
[1] Xinxiang Med Univ, Affiliated Hosp 1, Dept Intervent Radiol, Xinxiang, Henan, Peoples R China
[2] 88 Jian Kang Rd, Jian 453100, Henan, Peoples R China
[3] Shanghai Jiao Tong Univ, Affiliated Peoples Hosp 6, Dept Intervent Radiol, Fengxian Hosp, Shanghai 200233, Peoples R China
[4] 600 Yi Shan Rd, Shanghai 200233, Peoples R China
[5] 6600 Nan Feng Rd, Shanghai 210499, Peoples R China
[6] Shanghai Jiao Tong Univ, Natl Engn Res Ctr Light Alloy Net Forming, Shanghai 200240, Peoples R China
[7] Shanghai Jiao Tong Univ, State Key Lab Met Matrix Composite, Shanghai 200240, Peoples R China
[8] 800 Dong Chuan Rd, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
Mg alloy stent; Common carotid artery; Degradation; Intravascular ultrasound (IVUS); Covered stent; GUGLIELMI DETACHABLE COILS; UNRUPTURED CEREBRAL ANEURYSMS; IN-VITRO DEGRADATION; INTRACRANIAL ANEURYSMS; CORONARY-ARTERIES; SHEAR-STRESS; SUBARACHNOID HEMORRHAGE; FLOW-DIVERSION; TRIAL; IMPLANTATION;
D O I
10.1007/s00330-016-4715-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To analyze the outcomes of a magnesium alloy covered stent (MACS) for a lateral aneurysm model in common carotid artery (CCA). In 32 rabbits, a MACS (group A, n = 17) or a Willis covered stent (WCS; group B, n = 15) was inserted and the rabbits were sacrificed 1, 3, 6, or 12 months after stenting. Angiography and intravascular ultrasound (IVUS) were performed at 3, 6, and 12 months. Scanning electron microscopy was performed for six stents in each group at 1, 3, and 6 months, and histopathology and histomorphology were conducted at 3 (n = 4), 6 (n = 4), and 12 (n = 12) months. Final angiography showed complete occlusion of the aneurysms in 12 cases. IVUS at 6 and 12 months revealed a significant increase in mean lumen area of the stented CCA in group A and also showed greater mean lumen area in group A than in group B. The endothelialization process was quicker in group A than in group B. MACS is effective for occlusion of lateral aneurysms and is superior to WCS in growth of the stented CCA and endothelialization. Further work is needed to make this device available for human use. aEuro cent The MACS is an effective approach for occlusion of a lateral aneurysm. aEuro cent IVUS showed that the CCA could grow following degradation of the MACS. aEuro cent The lumen area of the stented CCA was excellent in MACS. aEuro cent HE staining displayed the degradation of the magnesium alloy stent. aEuro cent Combination of IVUS and DSA were applied in this study.
引用
收藏
页码:3694 / 3702
页数:9
相关论文
共 50 条
  • [31] Silicone-covered biodegradable magnesium stent for treating benign esophageal stricture in a rabbit model
    Kai Yang
    Jun Cao
    Tian-Wen Yuan
    Yue-Qi Zhu
    Bi Zhou
    Ying-Sheng Cheng
    World Journal of Gastroenterology, 2019, 25 (25) : 3207 - 3217
  • [32] Silicone-covered biodegradable magnesium stent for treating benign esophageal stricture in a rabbit model
    Yang, Kai
    Cao, Jun
    Yuan, Tian-Wen
    Zhu, Yue-Qi
    Zhou, Bi
    Cheng, Ying-Sheng
    WORLD JOURNAL OF GASTROENTEROLOGY, 2019, 25 (25) : 3207 - 3217
  • [33] A pilot study of a novel biodegradable magnesium alloy airway stent in a rabbit model
    Xue, Bangde
    Liang, Beibei
    Yuan, Guangyin
    Zhu, Limin
    Wang, Hao
    Lu, Zhaohui
    Xu, Zhiwei
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2019, 117 : 88 - 95
  • [34] Comparative study of covered stent with coil embolization in the treatment of cranial internal carotid artery aneurysm: a nonrandomized prospective trial
    Ming-Hua Li
    Bing Leng
    Yong-Dong Li
    Hua-Qiao Tan
    Wu Wang
    Dong-Lei Song
    Yan-Long Tian
    European Radiology, 2010, 20 : 2732 - 2739
  • [35] Comparative study of covered stent with coil embolization in the treatment of cranial internal carotid artery aneurysm: a nonrandomized prospective trial
    Li, Ming-Hua
    Leng, Bing
    Li, Yong-Dong
    Tan, Hua-Qiao
    Wang, Wu
    Song, Dong-Lei
    Tian, Yan-Long
    EUROPEAN RADIOLOGY, 2010, 20 (11) : 2732 - 2739
  • [36] Revascularization of Left Subclavian to Common Carotid Artery Prepares for Covered Stent Implantation in Patients With Complex Aortic Coarctation
    Schleiger, Anastasia
    Michel, Joerg
    Kramer, Peter
    Buz, Semih
    Peters, Bjorn
    Photiadis, Joachim
    Berger, Felix
    Nordmeyer, Johannes
    Schubert, Stephan
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2022, 17 (03) : 237 - 243
  • [37] The Clinical Efficacy Analysis of Treatment With a Willis Covered Stent in Traumatic Pseudoaneurysm of the Internal Carotid Artery
    Zhao, Yueyuan
    Liu, Zhiwen
    Sun, Ronghui
    Pan, Li
    Yang, Ming
    Song, Jian
    Ma, Lianting
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [38] Using PTFE covered stent-artery anastomosis in a new hybrid operation for giant juxta-skull internal carotid aneurysm with tortuous internal carotid artery
    Wu, Jianjin
    Chen, Yi
    Qu, Lefeng
    He, Yuan
    Zhi, Kangkang
    Bai, Jun
    Zou, Sili
    Wu, Yongfa
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 185 : 25 - 28
  • [39] ANEURYSM OF THE RABBIT COMMON CAROTID-ARTERY INDUCED BY PERIARTERIAL APPLICATION OF CALCIUM-CHLORIDE INVIVO
    GERTZ, SD
    KURGAN, A
    EISENBERG, D
    JOURNAL OF CLINICAL INVESTIGATION, 1988, 81 (03): : 649 - 656
  • [40] An in vitro porcine model evaluating a novel stent retriever for thrombectomy of the common carotid artery
    Jiang, Yongjun
    Li, Yun
    Xu, Xiaomeng
    Yu, Yongyi
    Liu, Wenhua
    Liu, Xinfeng
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (03) : 457 - 464