A Flexible Optical pH Sensor Based on Polysulfone Membranes Coated with pH-Responsive Polyaniline Nanofibers

被引:51
|
作者
Abu-Thabit, Nedal [1 ]
Umar, Yunusa [1 ]
Ratemi, Elaref [1 ]
Ahmad, Ayman [1 ]
Abuilaiwi, Faraj Ahmad [2 ]
机构
[1] Jubail Ind Coll, Dept Chem & Proc Engn Technol, Jubail Ind City 31961, Saudi Arabia
[2] Univ Hafr Al Batin, Dept Chem, Coll Sci, Hafar al Batin 31991, Saudi Arabia
关键词
optical pH sensor membrane; flexible pH sensor; polysulfone; polyaniline; chemical oxidative polymerization; nanofibers; CHEMICAL SENSORS; THIN-FILMS; SOL-GEL; POLYMERIZATION; BIOSENSORS; SENSITIVITY; CALIBRATION; COMPOSITE; POLYMERS; PURPLE;
D O I
10.3390/s16070986
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new optical pH sensor based on polysulfone (PSU) and polyaniline (PANI) was developed. A transparent and flexible PSU membrane was employed as a support. The electrically conductive and pH-responsive PANI was deposited onto the membrane surface by in situ chemical oxidative polymerization (COP). The absorption spectra of the PANI-coated PSU membranes exhibited sensitivity to pH changes in the range of 4-12, which allowed for designing a dual wavelength pH optical sensor. The performance of the membranes was assessed by measuring their response starting from high pH and going down to low pH, and vice versa. It was found that it is necessary to precondition the sensor layers before each measurement due to the slight hysteresis observed during forward and backward pH titrations. PSU membranes with polyaniline coating thicknesses in the range of approximate to 100-200 nm exhibited fast response times of <4 s, which are attributed to the porous, rough and nanofibrillar morphology of the polyaniline coating. The fabricated pH sensor was characterized by a sigmoidal response (R-2 = 0.997) which allows for pH determination over a wide dynamic range. All membranes were stable for a period of more than six months when stored in 1 M HCl solution. The reproducibility of the fabricated optical pH sensors was found to be <0.02 absorption units after one month storage in 1 M HCl solution. The performance of the optical pH sensor was tested and the obtained pH values were compared with the results obtained using a pH meter device.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Microporous thin film membranes from pH-responsive polymer
    Tokarev, Ihor
    Orlov, Maxim
    Minko, Sergiy
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233
  • [42] Preparation of pH-responsive polymer membranes by self-organization
    Hester, JF
    Olugebefola, SC
    Mayes, AM
    JOURNAL OF MEMBRANE SCIENCE, 2002, 208 (1-2) : 375 - 388
  • [43] Highly pH-responsive sensor based on amplified spontaneous emission coupled to colorimetry
    Zhang, Qi
    Smirnov, Jose R. Castro
    Xia, Ruidong
    Pedrosa, Jose M.
    Rodriguez, Isabel
    Cabanillas-Gonzalez, Juan
    Huang, Wei
    SCIENTIFIC REPORTS, 2017, 7
  • [44] Highly pH-responsive sensor based on amplified spontaneous emission coupled to colorimetry
    Qi Zhang
    Jose R. Castro Smirnov
    Ruidong Xia
    Jose M. Pedrosa
    Isabel Rodriguez
    Juan Cabanillas-Gonzalez
    Wei Huang
    Scientific Reports, 7
  • [45] pH-Responsive Micelles Based on Caprylic Acid
    Salentinig, Stefan
    Phan, Stephanie
    Darwish, Tamim A.
    Kirby, Nigel
    Boyd, Ben J.
    Gilbert, Elliot P.
    LANGMUIR, 2014, 30 (25) : 7296 - 7303
  • [46] Investigating the Time Response of an Optical pH Sensor Based on a Polysiloxane-Polyethylene Glycol Composite Material Impregnated with a pH-Responsive Triangulenium Dye
    Frankaer, Christian G.
    Sorensen, Thomas J.
    ACS OMEGA, 2019, 4 (05): : 8381 - 8389
  • [47] The pH sensor based optical fiber coated with PAH/PAA
    Yatim, Khairiah Mohd
    Krishnan, Ganesan
    Bakhtiar, Hazri
    Daud, Suzairi
    Harun, Sulaiman Wadi
    PHOTONICS MEETING 2019, THE 2ND ANNUAL CONFERENCE AND WORKSHOP, 2019, 1371
  • [48] A novel pH-responsive controlled release system based on mesoporous silica coated with hydroxyapatite
    Cui, Liru
    Lin, Huiming
    Guo, Wei
    Xiang, Di
    Zhou, Dan
    Zhang, Ting
    Qu, Fengyu
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2014, 72 (01) : 106 - 113
  • [49] A novel pH-responsive controlled release system based on mesoporous silica coated with hydroxyapatite
    Liru Cui
    Huiming Lin
    Wei Guo
    Di Xiang
    Dan Zhou
    Ting Zhang
    Fengyu Qu
    Journal of Sol-Gel Science and Technology, 2014, 72 : 106 - 113
  • [50] A pH-responsive drug delivery system based on chitosan coated mesoporous silica nanoparticles
    Popat, Amirali
    Liu, Jian
    Lu, Gao Qing
    Qiao, Shi Zhang
    JOURNAL OF MATERIALS CHEMISTRY, 2012, 22 (22) : 11173 - 11178