Nanostructured electrodes for biocompatible CMOS integrated circuits

被引:10
|
作者
Graham, Anthony H. D. [1 ]
Bowen, Chris R. [2 ]
Robbins, Jon [3 ]
Lalev, Georgi [4 ]
Marken, Frank [5 ]
Taylor, John [1 ]
机构
[1] Univ Bath, Dept Elect & Elect Engn, Bath BA2 7AY, Avon, England
[2] Univ Bath, Dept Mech Engn, Bath BA2 7AY, Avon, England
[3] Kings Coll London, Receptors & Signalling Wolfson CARD, Higher Educ Acad Teaching Practice, London SE1 1UL, England
[4] Cardiff Univ, Mfg Engn Ctr, Nanomfg Technol Lab, Cardiff CF24 3AA, S Glam, Wales
[5] Univ Bath, Dept Chem, Bath BA2 7AY, Avon, England
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2010年 / 147卷 / 02期
基金
英国工程与自然科学研究理事会;
关键词
Electrode; CMOS; Anodic aluminum oxide (AAO); Biocompatibility; Impedance; Biosensor; POROUS ANODIC ALUMINA; PULSED ELECTRODEPOSITION; NANOWIRE ARRAYS; BARRIER LAYER; CU ALLOY; SILICON; GROWTH; OXIDE; FABRICATION; TEMPLATE;
D O I
10.1016/j.snb.2010.03.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports on the adaptation of standard complementary metal oxide semiconductor (CMOS) integrated circuit (IC) technology for biocompatibility, enabling a low-cost solution for drug discovery pharmacology, neural interface systems, cell-based biosensors and electrophysiology. The basis for the process is the anodisation of IC aluminium electrodes to form nanoporous alumina. The porous alumina was electrochemically thinned to reduce the alumina electrode impedance. For applications where a porous electrode surface is either preferred or acceptable, we demonstrated that porosity can be manipulated at room temperature by modifying the anodising electrolyte to include up to 40% polyethylene glycol and reducing the phosphoric acid concentration from 4% (w/v) to 1%. For applications requiring a planar microelectrode surface, a noble metal was electrodeposited into the pores of the alumina film. Limited success was achieved with a pH 7 platinum and pH 5 gold cyanide bath but good results were demonstrated with a pH 0.5 gold chloride bath which produced planar biocompatible electrodes. A further reduction in impedance was produced by deposition of platinum-black, which may be a necessary additional step for demanding applications such as neuronal recording. During this work a capability for real-time electrochemical impedance spectroscopy (EIS) was developed to study anodisation, barrier oxide thinning, oxide breakdown and electrodeposition processes. To study the pore morphology, focused ion beam (FIB) was employed to produce cross-sectional cuts of the IC features which were inspected by SEM with an 'In-lens' detector. The anodisation process and the optional electrodeposition steps require only simple bench equipment operated at room temperature and is therefore a viable route for manufacturing low-cost biocompatible electrodes from standard CMOS ICs. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:697 / 706
页数:10
相关论文
共 50 条
  • [1] Applications of metallic borides for gate electrodes in CMOS integrated circuits
    Zagozdzon-Wosik, W
    Darne, C
    Radhakrishnan, D
    Rusakova, I
    van der Heide, P
    Zhang, ZH
    Bennett, J
    Trombetta, L
    Majhi, P
    Matron, D
    REVIEWS ON ADVANCED MATERIALS SCIENCE, 2004, 8 (02) : 185 - 194
  • [2] Terahertz CMOS Integrated Circuits
    Lee, Thomas H.
    2014 IEEE INTERNATIONAL SYMPOSIUM ON RADIO-FREQUENCY INTEGRATION TECHNOLOGY (RFIT): SILICON TECHNOLOGY HEATS UP FOR THZ, 2014,
  • [3] Design of Electrodes and Circuits for Cell Trapping on CMOS
    Park, Kyoungchul
    Kabiri, Shideh
    Sonkusale, Sameer
    2015 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2015, : 552 - 555
  • [4] Reverse Engineering of CMOS Integrated Circuits
    Masalskis, G.
    Navickas, R.
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2008, (08) : 25 - 28
  • [5] Novel integrated CMOS sensor circuits
    Kleinfelder, S
    Bieser, F
    Chen, YD
    Gareus, R
    Matis, HS
    Oldenburg, M
    Retiere, F
    Ritter, HG
    Wieman, HH
    Yamamoto, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2328 - 2336
  • [6] Phototransistors for CMOS Optoelectronic Integrated Circuits
    Kostov, P.
    Schneider-Hornstein, K.
    Zimmermann, H.
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 172 (01) : 140 - 147
  • [7] Paths to Terahertz CMOS Integrated Circuits
    Shim, D.
    Mao, C.
    Han, R.
    Sankaran, S.
    Seok, E.
    Cao, C.
    Knap, W.
    Kenneth, O.
    PROCEEDINGS OF THE IEEE 2009 CUSTOM INTEGRATED CIRCUITS CONFERENCE, 2009, : 657 - +
  • [8] RELIABILITY OF CMOS INTEGRATED-CIRCUITS
    SCHNABLE, GL
    GALLACE, LJ
    PUJOL, HL
    COMPUTER, 1978, 11 (10) : 6 - 17
  • [9] Scaling limits of CMOS integrated circuits
    Dilger, M
    NANOFAIR 2004 NEW IDEAS FOR INDUSTRY, 2004, 1839 : 17 - 23
  • [10] Crosstalk analysis in CMOS integrated circuits
    Novák, J
    Foit, J