Bond strengths of two adhesive systems to dentin contaminated with a hemostatic agent

被引:40
|
作者
Kuphasuk, W.
Harnirattisai, C.
Senawongse, P.
Tagami, J.
机构
[1] Mahidol Univ, Fac Dent, Dept Operat Dent, Bangkok 10700, Thailand
[2] Tokyo Med & Dent Univ, Grad Sch, Dept Restorat Sci, Tokyo, Japan
关键词
D O I
10.2341/06-121
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the bond strength of a total-etch and a self-etch adhesive to dentin contaminated with a hemostatic agent containing aluminum chloride (AlCl3). Eighteen occlusal dentin discs were prepared from human molars. Each disc was ground and sectioned into two halves, one for normal dentin and the other for contaminated dentin. The specimens of both normal and contaminated dentin were randomly divided into three groups and treated with the following materials: 1) Excite (EX); 2) Clearfil SE Bond with 20-second primer application time (CB 20) and 3) Clearfil SE Bond with 40-second primer application time (CB 40). The microshear bond strength specimens were prepared using the resin composite Clearfil APX. The bond strengths were evaluated on a universal testing machine. Statistical analysis was performed at alpha=0.05. The surface micromorphology and aluminum content of the different dentin conditions were also examined. In EX, no significant difference was found between the bond strengths of normal dentin and contaminated dentin. The bond strength of CB20 to contaminated dentin was significantly lower than that to normal dentin. The extension of primer application time from 20 to 40 seconds significantly increased the bond strength of CB to contaminated dentin.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 50 条
  • [41] Comparison of dentin bond durability of a universal adhesive and two etch-and-rinse adhesive systems
    Mami Kawazu
    Toshiki Takamizawa
    Eizo Hirokane
    Akimasa Tsujimoto
    Tomohiko Tamura
    Wayne W. Barkmeier
    Mark A. Latta
    Masashi Miyazaki
    [J]. Clinical Oral Investigations, 2020, 24 : 2889 - 2897
  • [42] BOND STRENGTH OF 5 ADHESIVE SYSTEMS TO DENTIN
    HADAVI, F
    HEY, J
    AMBROSE, ER
    QUDDUSI, S
    [J]. JOURNAL OF DENTAL RESEARCH, 1994, 73 : 130 - 130
  • [43] Dentin bond of one bottle adhesive systems
    Giannini, M
    Pimenta, LAF
    Dias, CTS
    [J]. JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1051 - 1051
  • [44] Bracket bond strengths of new adhesive systems
    Minick, Gerald T.
    Oesterle, Larry J.
    Newman, Sheldon M.
    Shellhart, William Craig
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (06) : 771 - 776
  • [45] Effect of tin–chloride pretreatment on bond strength of two adhesive systems to dentin
    Anne Peutzfeldt
    Tamara Koch
    Carolina Ganss
    Simon Flury
    Adrian Lussi
    [J]. Clinical Oral Investigations, 2014, 18 : 535 - 543
  • [46] Effect of 2% Chlorhexidine on the Bond Strength of Two Adhesive Systems to Human Dentin
    Bengtson, Camilla Regina Galvao
    Bengtson, Antonio Lucindo
    Bengtson, Nadya Galvao
    Turbino, Miriam Lacalle
    [J]. PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2008, 8 (01): : 51 - 56
  • [47] Bond strength evaluation of two adhesive systems on dentin treated with air abrasion
    Nogueira, L
    Teixeira, SC
    Araújo, MAM
    [J]. JOURNAL OF DENTAL RESEARCH, 2002, 81 : B173 - B173
  • [48] Microtensile bond strength between crown and root dentin and two adhesive systems
    De Goes, Mario Fernando
    Giannini, Marcelo
    Foxton, Richard Mark
    Nikaido, Toru
    Tagami, Junji
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2007, 97 (04): : 223 - 228
  • [49] Influence of metal conditioner contamination of the dentin surface on bond strengths of dentin adhesive systems using self-etching primers
    Yoshida, T
    Miyazaki, M
    Hirohata, N
    Moore, BK
    [J]. OPERATIVE DENTISTRY, 2005, 30 (03) : 359 - 367
  • [50] Influence of a simulated oral environment on dentin bond strength of two adhesive systems
    Besnault, C
    Attal, JP
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2001, 14 (06): : 367 - 372