Corneal power determination after previous corneal refractive surgery for intraocular lens calculation

被引:24
|
作者
Stakheev, AA
Balashevich, LJ
机构
关键词
myopia; corneal refractive surgery; LASIK; photorefractive keratectomy;
D O I
10.1097/00003226-200304000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the accuracy of different corneal power determination methods in patients who had undergone myopic laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and radial keratotomy (RK). Methods. The results for 208 eyes of 116 patients who had had corneal refractive surgery (LASIK, PRK, RK) for myopia were analyzed retrospectively. Keratometry measurements, i.e., autokeratometry readings (K-meas), simulated keratotopography readings (Sim-K), and topographically measured average central corneal power in a 3-mm zone (ACP) were compared with calculated refraction-derived keratometric value. Correction factors based on the difference between measured and calculated keratometric powers were rated. Results. Direct power measurements with standard keratometers and planokeratotopography systems overestimate corneal power after myopic PRK and LASIK. The average K-meas and K-topo were significantly greater than the average calculated refraction-derived keratometric values. Corneal power overestimation correlated significantly with the spherical equivalent change after refractive surgery (p < 0.001). After RK, there is no significant correlation of the difference between all measured K values and refraction-derived power with the spherical equivalent change. In these cases, the Sim-K value seems the most accurate among measured keratometric powers. The precision of measurement significantly depends on the parameters of the autokeratometer (i.e., measurement place, number of measurement points, keratometric index of refraction). Conclusions. To avoid underestimation of intraocular lens power after cataract surgery in the eyes that had previously undergone myopic corneal refractive surgery, the measured corneal power must be corrected. Although correction factors may be calculated for cases after PRK and LASIK, there are no universal and absolutely reliable methods to determine corneal power in these cases. More than one accessible method should be used, and the lowest, most reliable data should be used.
引用
下载
收藏
页码:214 / 220
页数:7
相关论文
共 50 条
  • [31] A new centralperipheral corneal curvature method for intraocular lens power calculation after excimer laser refractive surgery
    Saiki, Megumi
    Negishi, Kazuno
    Kato, Naoko
    Arai, Hiroyuki
    Toda, Ikuko
    Torii, Hidemasa
    Dogru, Murat
    Tsubota, Kazuo
    ACTA OPHTHALMOLOGICA, 2013, 91 (02) : e133 - e139
  • [32] Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery
    Wang, Li
    Spektor, Tatyana
    de Souza, Rodrigo G.
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1416 - 1421
  • [33] Clinical Results of a Corneal Radius Correcting Factor in Calculating Intraocular Lens Power After Corneal Refractive Surgery
    Rosa, Nicola
    Capasso, Luigi
    Lanza, Michele
    Borrelli, Maria
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (07) : 599 - 603
  • [34] Intraocular lens power calculation after refractive surgery
    Argento, C
    Cosentino, MJ
    Badoza, D
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1346 - 1351
  • [35] Trifocal diffractive intraocular lens implantation in patients after previous corneal refractive laser surgery for myopia
    Li, Qiu-Mei
    Wang, Feng
    Wu, Zhe-Ming
    Liu, Zhen
    Zhan, Chuan
    Chen, Bing-Heng
    Sima, Jing
    Stieger, Knut
    Li, Shao-Wei
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [36] Intraocular lens power calculation after myopic laser in situ keratomileusis: Estimating the corneal refractive power
    Awwad, Shady T.
    Manasseh, Christian
    Bowman, R. Wayne
    Cavanagh, H. Dwight
    Verity, Steven
    Mootha, Vinod
    McCulley, James P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (07): : 1070 - 1076
  • [37] IOL Power Calculation after Corneal Refractive Surgery
    De Bernardo, Maddalena
    Capasso, Luigi
    Caliendo, Luisa
    Paolercio, Francesco
    Rosa, Nicola
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [38] IOL power calculation after corneal refractive surgery
    Rosa, Nicola
    Capasso, Luigi
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (08) : 735 - 735
  • [39] Trifocal diffractive intraocular lens implantation in patients after previous corneal refractive laser surgery for myopia
    Qiu-Mei Li
    Feng Wang
    Zhe-Ming Wu
    Zhen Liu
    Chuan Zhan
    Bing-Heng Chen
    Jing Sima
    Knut Stieger
    Shao-Wei Li
    BMC Ophthalmology, 20
  • [40] Modified double-K method for intraocular lens power calculation after excimer laser corneal refractive surgery
    Saiki, Megumi
    Negishi, Kazuno
    Kato, Naoko
    Ogino, Rika
    Arai, Hiroyuki
    Toda, Ikuko
    Dogru, Murat
    Tsubota, Kazuo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (04): : 556 - 562