EFFECT OF MICROBUBBLE SIZE ON FUNDAMENTAL MODE HIGH FREQUENCY ULTRASOUND IMAGING IN MICE

被引:135
|
作者
Sirsi, Shashank [1 ]
Feshitan, Jameel [1 ]
Kwan, James [1 ]
Homma, Shunichi [2 ]
Borden, Mark [1 ]
机构
[1] Columbia Univ, Dept Chem Engn, New York, NY 10027 USA
[2] Columbia Univ, Med Ctr, Div Cardiol, New York, NY 10027 USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2010年 / 36卷 / 06期
关键词
Contrast agent; Diameter; Circulation persistence; Scattering cross-section; Absorption; Kidney; CONTRAST AGENTS; FILLED MICROBUBBLES; STANDARD PROPERTIES; TUMOR XENOGRAFTS; DRUG-DELIVERY; BUBBLE-SIZE; ATTENUATION; QUANTIFICATION; MICROSPHERES; INFLAMMATION;
D O I
10.1016/j.ultrasmedbio.2010.03.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
High-frequency ultrasound imaging using microbubble (MB) contrast agents is becoming increasingly popular in pre-clinical and small animal studies of anatomy, flow and vascular expression of molecular epitopes. Currently, in vivo imaging studies rely on highly polydisperse microbubble suspensions, which may provide a complex and varied acoustic response. To study the effect of individual microbubble size populations, microbubbles of 1-2 mu m, 4-5 mu m and 6-8 mu m diameter were isolated using the technique of differential centrifugation. Size-selected microbubbles were imaged in the mouse kidney over a range of concentrations using a Visualsonics Vevo 770 ultrasound imaging system (Visualsonics, Toronto, Ontario, Canada) with a 40-MHz probe in fundamental mode. Results demonstrate that contrast enhancement and circulation persistence are strongly dependent on microbubble size and concentration. Large microbubbles (4-5 and 6-8 mu m) strongly enhanced the ultrasound image with positive contrast, while 1-2 ?m microbubbles showed little enhancement. For example, the total integrated contrast enhancement, measured by the area under the time-intensity curve (AUC), increased 16-fold for 6-8 mu m diameter microbubbles at 5 x 10(7) MB/bolus compared with 4-5 mu m microbubbles at the same concentration. Interestingly, 1-2 mu m diameter microbubbles, at any concentration, did not measurably enhance the integrated ultrasound signal at tissue depth, but did noticeably attenuate the signal, indicating that they had a low scattering-to-attenuation ratio. When concentration matched, larger microbubbles were more persistent in circulation. However, when volume matched, all microbubble sizes had a similar circulation half-life. These results indicated that dissolution of the gas core plays a larger role in contrast elimination than filtering by the lungs and spleen. The results of this study show that microbubbles can be tailored for optimal contrast enhancement in fundamental mode imaging. (E-mail: mb2910@columbia.edu) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:935 / 948
页数:14
相关论文
共 50 条
  • [1] Myocardial ischemic memory imaging using fundamental high frequency ultrasound
    Bowry, Shyani
    Chen, Xucai
    Wang, Jianjun
    Schwartz, Abigail
    Wagner, William R.
    Villanueva, Flordeliza
    [J]. CIRCULATION, 2007, 116 (16) : 647 - 647
  • [2] Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging
    Shekhar, Himanshu
    Rychak, Joshua J.
    Doyley, Marvin M.
    [J]. MEDICAL PHYSICS, 2013, 40 (08)
  • [3] High frequency quantitative ultrasound imaging of solid tumors in mice
    Oelze, M. L.
    O'Brien, W. D., Jr.
    Zachary, J. F.
    [J]. ACOUSTICAL IMAGING, VOL 28, 2007, 28 : 301 - 306
  • [4] Microbubble Detection by Dual-High-Frequency Ultrasound Excitation
    Su, Shin-Yuan
    Shen, Che-Chou
    Yeh, Chih-Kuang
    [J]. 2008 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4 AND APPENDIX, 2008, : 1631 - +
  • [5] Microbubble Destruction by Dual-High-Frequency Ultrasound Excitation
    Yeh, Chih-Kuang
    Su, Shin-Yuan
    Shen, Che-Chou
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (05) : 1113 - 1118
  • [6] Imaging with high frequency ultrasound
    Reid, JM
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (11): : 1577 - 1577
  • [7] The effect of size range on ultrasound-induced translations in microbubble populationsa)
    Supponen, Outi
    Upadhyay, Awaneesh
    Lum, Jordan
    Guidi, Francesco
    Murray, Todd
    Vos, Hendrik J.
    Tortoli, Piero
    Borden, Mark
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2020, 147 (05): : 3236 - 3247
  • [8] Microbubble Composition and Preparation for High-Frequency Contrast-Enhanced Ultrasound Imaging: In Vitro and In Vivo Evaluation
    Daeichin, Verya
    van Rooij, Tom
    Skachkov, Ilya
    Ergin, Bulent
    Specht, Patricia A. C.
    Lima, Alexandre
    Ince, Can
    Bosch, Johan G.
    van der Steen, Antonius F. W.
    de Jong, Nico
    Kooiman, Klazina
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (03) : 555 - 567
  • [9] Radial modulation imaging of microbubble contrast agents at high frequency
    Cherin, Emmanuel
    Brown, Jeremy
    Masoy, Svein-Erik
    Shariff, Hamid
    Karshafian, Raffi
    Williams, Ross
    Burns, Peter N.
    Foster, F. Stuart
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (06): : 949 - 962
  • [10] Dual-high-frequency ultrasound excitation on microbubble destruction volume
    Shen, Che-Chou
    Su, Shin-Yuan
    Cheng, Chih-Hao
    Yeh, Chih-Kuang
    [J]. ULTRASONICS, 2010, 50 (07) : 698 - 703