Modifying the size distribution of microbubble contrast agents for high-frequency subharmonic imaging

被引:15
|
作者
Shekhar, Himanshu [1 ]
Rychak, Joshua J. [2 ,3 ]
Doyley, Marvin M. [1 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Targeson Inc, San Diego, CA 92121 USA
[3] Univ Calif San Diego, Dept Bioengn, San Diego, CA 92093 USA
关键词
nonlinear ultrasound imaging; subharmonic imaging; microbubble contrast agents; vasa vasorum imaging; atherosclerosis; PHOSPHOLIPID-ENCAPSULATED MICROBUBBLES; CODED EXCITATION; VASA VASORUM; ULTRASOUND; ATTENUATION; SENSITIVITY; SCATTERING;
D O I
10.1118/1.4813017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Subharmonic imaging is of interest for high frequency (>10 MHz) nonlinear imaging, because it can specifically detect the response of ultrasound contrast agents (UCA). However, conventional UCA produce a weak subharmonic response at high frequencies, which limits the sensitivity of subharmonic imaging. We hypothesized that modifying the size distribution of the agent can enhance its high-frequency subharmonic response. The overall goal of this study was to investigate size-manipulated populations of the agent to determine the range of sizes that produce the strongest subharmonic response at high frequencies (in this case, 20 MHz). A secondary goal was to assess whether the number or the volume-weighted size distribution better represents the efficacy of the agent for high-frequency subharmonic imaging. Methods: The authors created six distinct agent size distributions from the native distribution of a commercially available UCA (Targestar-P (R)). The median (number-weighted) diameter of the native agent was 1.63 mu m, while the median diameters of the size-manipulated populations ranged from 1.35 to 2.99 mu m. The authors conducted acoustic measurements with native and size-manipulated agent populations to assess their subharmonic response to 20 MHz excitation (pulse duration 1.5 mu s, pressure amplitudes 100-398 kPa). Results: The results showed a considerable difference between the subharmonic response of the agent populations that were investigated. The subharmonic response peaked for the agent population with a median diameter of 2.15 mu m, which demonstrated a subharmonic signal that was 8 dB higher than the native agent. Comparing the subharmonic response of different UCA populations indicated that microbubbles with diameters between 1.3 and 3 mu m are the dominant contributors to the subharmonic response at 20 MHz. Additionally, a better correlation was observed between the subharmonic response of the agent and the number-weighted size-distribution (R-2 = 0.98) than with the volume-weighted size distribution (R-2 = 0.53). Conclusions: Modifying the size distribution of the agent appears to be a viable strategy to improve the sensitivity of high-frequency subharmonic imaging. In addition, when the size distribution of the UCA has not been suitably modified, the number-weighted size distribution is a useful parameter to accurately describe the efficacy of the agent for high-frequency subharmonic imaging. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] High-frequency subharmonic pulsed-wave Doppler and color flow imaging of microbubble contrast agents
    Needles, A.
    Goertz, D. E.
    Karshafian, R.
    Cherin, E.
    Brown, A. S.
    Burns, P. N.
    Foster, F. S.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (07): : 1139 - 1151
  • [2] High-frequency, nonlinear flow imaging of microbubble contrast agents
    Goertz, DE
    Needles, A
    Burns, PN
    Foster, FS
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (03) : 495 - 502
  • [3] Subharmonic imaging with microbubble contrast agents: Initial results
    Shi, WT
    Forsberg, F
    Hall, AL
    Chia, RY
    Liu, JB
    Miller, S
    Thomenius, KE
    Wheatley, MA
    Goldberg, BB
    [J]. ULTRASONIC IMAGING, 1999, 21 (02) : 79 - 94
  • [4] Nonlinear subharmonic imaging with US microbubble contrast agents
    Shi, WT
    Forsberg, F
    Liu, J
    Needleman, L
    Goldberg, BB
    [J]. RADIOLOGY, 1999, 213P : 362 - 362
  • [5] High frequency subharmonic pulsed-wave Doppler and color flow imaging of microbubble contrast agents
    Needles, A
    Brown, AS
    Karshafian, R
    Burns, PN
    Foster, FS
    Goertz, DE
    [J]. 2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 629 - 632
  • [6] Radial modulation imaging of microbubble contrast agents at high frequency
    Cherin, Emmanuel
    Brown, Jeremy
    Masoy, Svein-Erik
    Shariff, Hamid
    Karshafian, Raffi
    Williams, Ross
    Burns, Peter N.
    Foster, F. Stuart
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (06): : 949 - 962
  • [7] High frequency nonlinear B-scan imaging of microbubble contrast agents
    Goertz, DE
    Cherin, E
    Needles, A
    Karshafian, R
    Brown, AS
    Burns, PN
    Foster, FS
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (01) : 65 - 79
  • [8] Subharmonic imaging of contrast agents
    Forsberg, F
    Shi, WT
    Goldberg, BB
    [J]. ULTRASONICS, 2000, 38 (1-8) : 93 - 98
  • [9] A new real-time high-frequency subharmonic contrast mode for mouse Imaging
    Needles, A.
    Graba, J.
    Bilan, C.
    Coulthard, T.
    Goertz, D. D. E.
    Foster, F. S.
    Goertz, D. E.
    Stapleton, S.
    Foster, F. S.
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 1069 - +
  • [10] Subharmonic Threshold for Chirp Excitations of High Frequency Contrast Agents
    Allen, John S.
    Hayashi, Rintaro
    Chitnis, Parag V.
    Mamou, Jonthan
    Ketterling, Jeffrey A.
    [J]. 2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,