A Novel Physiologic Model for the Study of Abdominal Compartment Syndrome (ACS)

被引:18
|
作者
Shah, Shinil K. [1 ,2 ]
Jimenez, Fernando [1 ]
Walker, Peter A. [1 ,2 ]
Xue, Hasen [1 ]
Uray, Karen S. [1 ,3 ]
Aroom, Kevin R. [1 ]
Fischer, Uwe M. [1 ,2 ,3 ]
Laine, Glen A. [3 ]
Stewart, Randolph H. [3 ]
Norbury, Kenneth C. [4 ]
Cox, Charles S., Jr. [1 ,2 ,3 ]
机构
[1] Univ Texas Med Sch Houston, Dept Pediat Surg, Houston, TX 77030 USA
[2] Univ Texas Med Sch Houston, Dept Surg, Houston, TX 77030 USA
[3] Texas A&M Univ, Michael E De Bakey Inst Comparat Cardiovasc Sci &, College Stn, TX USA
[4] Kinet Concepts Inc, San Antonio, TX USA
关键词
Compartment syndrome; Models; Animal; Trauma; Resuscitation; Abdomen; MULTIPLE ORGAN FAILURE; INTESTINAL EDEMA DECREASES; INDUCED GUT EDEMA; PORCINE MODEL; SALINE; HYPOPROTEINEMIA; DYSFUNCTION; OPERATIONS; HARBINGERS; STIFFNESS;
D O I
10.1097/TA.0b013e3181c453cb
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Current abdominal compartment syndrome (ACS) models rely on intraperitoneal instillation of fluid, air, and other space-occupying substances. Although this allows for the study of the effects of increased abdominal pressure, it poorly mimics its pathogenesis. We have developed the first reported large animal model of ACS incorporating hemorrhagic shock/resuscitation. Methods: Hemorrhagic shock was induced and maintained ( 1 hour) in 12 Yorkshire swine by bleeding to a mean arterial pressure ( MAP) of 50 mm Hg. The collected blood plus two additional volumes of crystalloid was then reinfused. Mesenteric venous hypertension was induced by tightening a previously placed portal vein snare in a nonocclusive manner to mimic the effects of abdominal packing. Crystalloids were infused to maintain MAP. Hemodynamic measurements, abdominal pressure, peak inspiratory pressures, urine output, and blood chemistries were measured sequentially. Animals were studied for 36 hours after decompression. Results: ACS (intra-abdominal pressure of >= 20 mm Hg with new organ dysfunction) developed in all animals. There were significant increases in peak inspiratory pressure, central venous pressure, and pulmonary artery pressure and decreases in MAP upon development of ACS. Urine output was significantly decreased before decompression. Mean blood lactate decreased and base excess increased significantly after decompression. Conclusions: We have created the first reported physiologic animal ACS model incorporating hemorrhagic shock/resuscitation and the effects of damage control surgery.
引用
收藏
页码:682 / 689
页数:8
相关论文
共 50 条
  • [31] Abdominal compartment syndrome
    Scott T. Reeves
    Mark L. Pinosky
    T. Karl Byrne
    E. Douglas Norcross
    Canadian Journal of Anaesthesia, 1997, 44 : 308 - 312
  • [32] Abdominal compartment syndrome
    van Mook, WNKA
    Huslewe-Evers, RPMG
    LANCET, 2002, 360 (9344): : 1502 - 1502
  • [33] Abdominal compartment syndrome
    De Backer, D
    CRITICAL CARE, 1999, 3 (06): : R103 - R104
  • [34] Abdominal compartment syndrome
    Cheatham, Michael Lee
    CURRENT OPINION IN CRITICAL CARE, 2009, 15 (02) : 154 - 162
  • [35] Abdominal compartment syndrome
    Decker, G
    JOURNAL DE CHIRURGIE, 2001, 138 (05): : 270 - 276
  • [36] Abdominal compartment syndrome
    Wilhelm, S
    Standl, T
    ANASTHESIOLOGIE & INTENSIVMEDIZIN, 2004, 45 (01): : 14 - 22
  • [37] Abdominal compartment syndrome
    Bailey, J
    Shapiro, MJ
    CRITICAL CARE, 2000, 4 (01): : 23 - 29
  • [38] Abdominal compartment syndrome
    Maerz, Linda
    Kaplan, Lewis J.
    CRITICAL CARE MEDICINE, 2008, 36 (04) : S212 - S215
  • [39] ABDOMINAL COMPARTMENT SYNDROME
    Berude, Maria E.
    Villagran, C. Federico
    Novati, Laura
    Faraoni, Ernesto
    Di Salvo, Hector
    REVISTA ARGENTINA DE RESIDENTES DE CIRUGIA, 2010, 15 (1-2): : 9 - 15
  • [40] Abdominal compartment syndrome
    Sugrue, M
    CURRENT OPINION IN CRITICAL CARE, 2005, 11 (04) : 333 - 338