Rare case of implantable cardioverter defibrillator infection caused by Stenotrophomonas maltophilia and Pantoea calida

被引:7
|
作者
Ajam, Mustafa [1 ]
Shokr, Mohamed [2 ]
Ajam, Firas [3 ]
Lieberman, Randy [2 ]
机构
[1] Detroit Med Ctr, Internal Med, Detroit, MI 48201 USA
[2] Wayne State Univ, DMC, Cardiol, Detroit, MI USA
[3] Jersey Shore Univ, Med Ctr, Internal Med, Neptune City, NJ USA
关键词
infectious diseases; pacing and electrophysiology;
D O I
10.1136/bcr-2019-230506
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Despite the numerous advancements in cardiac implantable electronic defibrillator (CIED) designs and implantation techniques, device-related infections continue to represent significant morbidity and mortality. Although Gram-positive bacteria remain the most commonly reported organisms, various other bacterial families have been reported. We describe a 61-year-old patient with a history of non-ischaemic cardiomyopathy who presented with implantable cardioverter defibrillator pocket infection due to Stenotrophomonas maltophilia and Pantoea calida that developed a few days following the device generator replacement. Early device explantation, tissue sampling and initiation of sensitivity-directed antibiotics are necessary steps for early diagnosis and management of such CIED-related infections. S. maltophilia and P. calida should be added to the expanding list of the causative organisms behind CIED-related infections. Our case and available literature demonstrated excellent sensitivity of these two organisms to sulfamethoxazole-trimethoprim treatment.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] INFECTION OF IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR SYSTEMS - A PREVENTABLE COMPLICATION
    SHAHIAN, DM
    WILLIAMSON, WA
    MARTIN, D
    VENDITTI, FJ
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (10): : 1956 - 1960
  • [33] Neonatal infection with Stenotrophomonas maltophilia (2 case studies)
    Issaoui, S.
    Maoulainine, F. M. R.
    Elidrissi, N. S.
    Sorra, N.
    Chabaa, L.
    Aboussad, A.
    ARCHIVES DE PEDIATRIE, 2012, 19 (04): : 404 - 407
  • [34] CASE PRESENTATION OF URINARY TRACT INFECTION BY STENOTROPHOMONAS MALTOPHILIA
    Seitopoulou, C.
    Stamouli, M.
    Kalliora, G.
    Mourtzikou, A.
    INFEKTSIYA I IMMUNITET, 2024, 14 (02): : 392 - 396
  • [35] Case Report: Inappropriate Discharge of an Implantable Cardioverter-Defibrillator Caused by the Combined Count Criterion
    Wolpert C.
    Jung W.
    Spehl S.
    Korte T.
    Lüderitz B.
    Journal of Interventional Cardiac Electrophysiology, 1997, 2 (1) : 53 - 56
  • [36] Pocket infection as a complication of a subcutaneous implantable cardioverter-defibrillator
    Calvagna, Giuseppe Mario
    Ceresa, Fabrizio
    Patane, Salvatore
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (02) : 616 - 618
  • [37] Implantable cardioverter-defibrillator infection due to Corynebacterium xerosis
    Marti, Juan
    Anton, Enrique
    Idoate, Ana
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2008, 128 (01) : E1 - E2
  • [38] Meningitis caused by Stenotrophomonas maltophilia:: Case report and review of the literature
    Caylan, R
    Aydin, K
    Koksal, I
    ANNALS OF SAUDI MEDICINE, 2002, 22 (3-4) : 216 - 218
  • [39] ERRONEOUS DISCHARGE OF AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR CAUSED BY AN ELECTRIC RAZOR
    SEIFERT, T
    BLOCK, M
    BORGGREFE, M
    BREITHARDT, G
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (08): : 1592 - 1594
  • [40] Bronchomediastinal fistula caused by implantable cardioverter defibrillator epicardial patch electrode
    Driscoll, JA