Hold-up time in gas chromatography -: IV.: Improved determination of Kovats' retention indices

被引:14
|
作者
Lebrón-Aguilar, R [1 ]
García-Domínguez, JA [1 ]
Quintanilla-López, JE [1 ]
机构
[1] CSIC, Inst Quim Fis Rocasolano, E-28006 Madrid, Spain
关键词
retention times; retention indices; alkanes;
D O I
10.1016/S0021-9673(98)00037-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Kovats' retention indices of n-alkanes eluted under isothermal conditions, in nine columns (packed and capillary), at temperatures between 60 and 150 degrees C are calculated by three different methods, and the results are compared with their theoretical values. Two of the methods are based on the linearity assumption of the plot of the logarithms of the adjusted retention times versus carbon number. The third one does not accept the linearity assumption. Results show that methods based on the linearity assumption may produce a clear deviation from the true value of the retention index, while the third method tested, considerably improves the accuracy of the results, showing a similar precision than that obtained by the classical procedures. (C) 1998 Elsevier Science B.V.
引用
收藏
页码:161 / 168
页数:8
相关论文
共 50 条
  • [31] Cluster and principal component analysis for Kovats retention indices on apolar and polar stationary phases in gas chromatography
    Dallos, A.
    Ngo, H. S.
    Kresz, R.
    Heberger, K.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1177 (01) : 175 - 182
  • [32] An Improved Synchronous Rectification LLC Resonant Converter for Hold-Up Time Operation
    Luo, Zuohao
    Wu, Zaijun
    Quan, Xiangjun
    Hu, Qinran
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (06) : 8305 - 8314
  • [33] Evaluation of Hold-Up Volume Determination Methods and Markers in Hydrophilic Interaction Liquid Chromatography
    Redon, Lidia
    Subirats, Xavier
    Roses, Marti
    MOLECULES, 2023, 28 (03):
  • [34] The hold-up time in gas chromatography .2. Validation of the estimation based on the concept of a zero carbon atoms alkane
    QuintanillaLopez, JE
    LebronAguilar, R
    GarciaDominguez, JA
    JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) : 127 - 136
  • [35] THEORETICAL CALCULATION OF GAS HOLD-UP TIME IN CAPILLARY GAS-CHROMATOGRAPHY - INFLUENCE OF COLUMN, INSTRUMENT PARAMETERS AND ANALYSIS CONDITIONS AND COMPARISON OF DIFFERENT METHODS OF DEAD-TIME DETERMINATION
    CASTELLO, G
    VEZZANI, S
    MORETTI, P
    JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (01) : 95 - 106
  • [36] Exploring the application limits of different hold-up time markers in supercritical fluid chromatography
    Csanád Rédei
    Alessandro Buratti
    Martina Catani
    Attila Felinger
    Analytical and Bioanalytical Chemistry, 2024, 416 : 1485 - 1492
  • [37] Exploring the application limits of different hold-up time markers in supercritical fluid chromatography
    Redei, Csanad
    Buratti, Alessandro
    Catani, Martina
    Felinger, Attila
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (06) : 1485 - 1492
  • [38] GAS HOLD-UP AND RESIDENCE TIME DISTRIBUTION OF GAS-BUBBLES IN A TOWER TYPE GAS ENTRAINER
    KONISHI, H
    MATSUMURA, M
    KOBAYASHI, J
    HAKKOKOGAKU KAISHI-JOURNAL OF THE SOCIETY OF FERMENTATION TECHNOLOGY, 1982, 60 (06): : 423 - 431
  • [39] Impact of an error in the column hold-up time for correct adsorption isotherm determination in chromatography - I. Even a small error can lead to a misunderstanding of the retention mechanism
    Samuelsson, Joergen
    Sajonz, Peter
    Fornstedt, Torgny
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1189 (1-2) : 19 - 31
  • [40] Improved Hold-Up Time for WBG-based Single-Phase Converters
    Rajamony, Rajesh
    Ming, Wenlong
    2019 21ST EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE '19 ECCE EUROPE), 2019,