Lead-selective electrode based on the misfit compound (PbS)1.18TiS2

被引:0
|
作者
Velikanova, TV [1 ]
Titov, AN [1 ]
Shishmintseva, NN [1 ]
机构
[1] Ural State Univ, Yekaterinburg 620083, Russia
基金
俄罗斯基础研究基金会;
关键词
Active Element; Ag2S; Methyl Ethyl Ketone; Lead Sulfide; TiS2;
D O I
10.1007/BF02757330
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A lead-selective solid-contact electrode was prepared on the basis of the misfit compound (PbS)(1.18)TiS2 The electrode exhibits the slope of the electrode function is -(26 +/- 1) mV/pc and provides the determination of 1 x 10(-5)-5 x 10(-2) M lead in the pH range 2.75-5.0. High selectivity of the electrode for Ni2+ Co2+, Zn2+, Cu2+, Ag+, K+, Ba2+, and Sr2+ ions was demonstrated. The addition of graphite to the active phase of the membrane impaired the selectivity of the electrode. The electrode was used for the potentiometric indication of the titration end point in the determination of lead in copper alloys.
引用
收藏
页码:1051 / 1054
页数:4
相关论文
共 50 条
  • [21] LEAD-SELECTIVE NEUTRAL CARRIER BASED LIQUID MEMBRANE-ELECTRODE
    LINDNER, E
    TOTH, K
    PUNGOR, E
    BEHM, F
    OGGENFUSS, P
    WELTI, DH
    AMMANN, D
    MORF, WE
    PRETSCH, E
    SIMON, W
    ANALYTICAL CHEMISTRY, 1984, 56 (07) : 1127 - 1131
  • [22] Prominent texturing and enhanced thermoelectric performance of misfit layered (PbS)1.18(TiS2)2 via an exfoliation-restacking approach
    Bai, Chunhua
    Wang, Junjia
    Ding, Mannv
    Lang, Yudong
    Pan, Lin
    Wang, Yifeng
    He, Shengping
    Wan, Chunlei
    Ahmad, Kaleem
    Almutairi, Zeyad
    JOURNAL OF ALLOYS AND COMPOUNDS, 2024, 976
  • [23] Lead-selective electrode by using benzyl disulphide as ionophore
    Abbaspour, A
    Tavakol, F
    ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) : 145 - 149
  • [24] Lead-selective membrane electrode based on dibenzopyrydino-18-crown-6
    Tavakkoli, N
    Shamsipur, M
    ANALYTICAL LETTERS, 1996, 29 (13) : 2269 - 2279
  • [25] A lead-selective membrane electrode based upon a phosphorylated hexahomotrioxacalix[3]arene
    Yaftian, Mohammad Reza
    Parinejad, Massoumeh
    Matt, Dominique
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (06) : 1535 - 1542
  • [26] LEAD-SELECTIVE ELECTRODES BASED ON LEAD(IV) OXIDE
    MIDGLEY, D
    ANALYTICA CHIMICA ACTA, 1984, 159 (MAY) : 63 - 70
  • [27] LEAD-SELECTIVE ELECTRODES BASED ON LEAD AND SILVER SULFIDES
    VLASOV, YG
    ERMOLENKO, YE
    ISKHAKOVA, OA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1979, 34 (08): : 1175 - 1178
  • [28] CONTINUOUS-FLOW DETERMINATION OF SULFATE WITH A LEAD-SELECTIVE ELECTRODE
    HARA, H
    HORVAI, G
    PUNGOR, E
    ANALYST, 1988, 113 (12) : 1817 - 1820
  • [29] Lead-selective poly(vinyl cholride) membrane electrode based on piroxicam as a neutral carrier
    Sadeghi, S
    Dashti, GR
    Shamsipur, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 81 (2-3): : 223 - 228
  • [30] LEAD-SELECTIVE ELECTRODES BASED ON MACROCYCLIC REAGENTS
    NOVIKOV, EA
    SHPIGUN, LK
    ZOLOTOV, YA
    JOURNAL OF ANALYTICAL CHEMISTRY OF THE USSR, 1987, 42 (05): : 701 - 705