Modelling the measurement accuracy of pre-atmosphere velocities of meteoroids

被引:43
|
作者
Vida, Denis [1 ,2 ]
Brown, Peter G. [2 ]
Campbell-Brown, Margaret [2 ]
机构
[1] Univ Western Ontario, Dept Earth Sci, London, ON N6A 5B7, Canada
[2] Univ Western Ontario, Dept Phys & Astron, London, ON N6A 3K7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
comets; meteors; meteoroids; 2011 OCTOBER DRACONIDS; FAINT METEORS; LIGHT CURVES; ORBIT-RADAR; SHOWERS; VIDEO; FRAGMENTATION; TRAJECTORIES; POPULATIONS; OUTBURST;
D O I
10.1093/mnras/sty1841
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Many existing optical meteor trajectory estimation methods use the approximation that the velocity of the meteor at the beginning of its luminous phase is equivalent to its velocity before atmospheric entry. Meteoroid kinetic energy loss prior to the luminous phase cannot be measured, but for some masses and entry geometries neglecting this loss may lead to non-negligible deceleration prior to thermal ablation. Using a numerical meteoroid ablation model, we simulate the kinematics of meteoroids beginning at 180 km with initial velocities ranging from 11 km s(-1) to 71 km s(-1), and compare model velocities at the moment of detection to measurements. We validate the simulations by comparing the simulated luminous beginning heights with observed beginning heights of different populations of meteors detected with different optical systems. We find that most low-velocity meteoroids have a significant velocity difference of 100 ms(-1) to 750 ms(-1) (depending on meteoroid type, mass, and observation system). This systematic underestimate of meteoroid speeds also results in systematically lower semimajor axes for meteoroid orbits.
引用
收藏
页码:4307 / 4319
页数:13
相关论文
共 36 条
  • [31] Modelling 18O2 and 16O2 unidirectional fluxes in plants: I. Regulation of pre-industrial atmosphere
    Andre, Marcel J.
    BIOSYSTEMS, 2011, 103 (02) : 239 - 251
  • [32] Measurement and modelling of strain-path dependent anisotropic hardening behaviors of high strength steels subjected to pre-strains
    Aung, Thein Lin
    Ma, Ninshu
    Okitsu, Yoshitaka
    Hayashi, Seiji
    Takada, Kenji
    Naito, Tadashi
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2023, 23 : 451 - 465
  • [33] Assessing the effects of head modelling errors and measurement noise on EEG source localization accuracy in preterm newborns: A single-subject study
    Azizollahi, Hamed
    Aarabi, Ardalan
    Kazemi, Kamran
    Wallois, Fabrice
    EUROPEAN JOURNAL OF NEUROSCIENCE, 2023, 58 (03) : 2746 - 2765
  • [34] Improving the accuracy of global precipitation measurement integrated multi-satellite retrievals (GPM IMERG) using atmosphere precipitable water and altitude in climatic regions of Iran
    Beyk Ahmadi, Niloufar
    Rahimzadegan, Majid
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2021, 42 (07) : 2759 - 2781
  • [35] Accuracy of Post-Void Residual Urine Volume Measurement Using a Portable Ultrasound Bladder Scanner With Real-Time Pre-Scan Imaging
    Park, Yong Hyun
    Ku, Ja Hyeon
    Oh, Seung-June
    NEUROUROLOGY AND URODYNAMICS, 2011, 30 (03) : 335 - 338
  • [36] Real-time high-accuracy 3D facial (micro) expression measurement based on pre-aligned micro-projection arrays
    Guo, Yanqiong
    You, Zhisheng
    Lv, Kun
    Ren, Kun
    Xiong, Wei
    OPTICS EXPRESS, 2025, 33 (05): : 11077 - 11096