Comparison of surface contamination monitors for in vivo measurement of 131I in the thyroid

被引:0
|
作者
Oliveira, S. M. [1 ]
Dantas, A. L. A. [1 ]
Dantas, B. M. [1 ]
机构
[1] Inst Radioprotecao & Dosimetria, Rio de Janeiro, Brazil
关键词
D O I
10.1088/1742-6596/733/1/012100
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The routine handling of radiopharmaceuticals in nuclear medicine represents a significant risk of internal exposure to the staff. The IAEA recommends the implementation of monitoring plans for all workers subject to a risk of exposures above 1 mSv per year. However, in Brazil, such recommendation is practically unfeasible due to the lack of a sufficient number of qualified internal dosimetry services over the country. This work presents an alternative based on a simple and inexpensive methodology aimed to perform in vivo monitoring of I-131 in the thyroid using portable surface contamination probes. Results show that all models evaluated in this work present enough sensitivity for the evaluation of accidental intakes.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Assurance of the traceability chain for 131I measurement
    Sahagia, Maria
    Razdolescu, Anamaria Cristina
    Ivan, C.
    Luca, A.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (04) : 539 - 544
  • [32] 131I Abnormal Uptake by the Thyroid Bed From Zuckerkandl Tubercle Diagnosis by 131I SPECT/CT
    Kawabe, Joji
    Higashiyama, Shigeaki
    Kotani, Kohei
    Onoda, Naoyoshi
    Shiomi, Susumu
    CLINICAL NUCLEAR MEDICINE, 2015, 40 (03) : 275 - 277
  • [33] 131I Thyroid lesion dosimetry with quantitative imaging
    Richetta, E.
    Cutaia, C.
    Codegone, A.
    Garbaccio, V.
    Pellerito, R.
    Stasi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S405 - S406
  • [34] RADIATION THYROID CELLS AND 131I THERAPY - A HYPOTHESIS
    GREIG, WR
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1965, 25 (10): : 1411 - +
  • [35] THYROID 131I BURDENS IN MEDICAL AND PARAMEDICAL PERSONNEL
    BLUM, M
    LIUZZI, A
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1967, 200 (11): : 992 - &
  • [36] EFFECT OF PROPYLTHIOURACIL AND 131I ON RAT THYROID CHROMOSOMES
    SPEIGHT, JW
    BABA, WI
    WILSON, GM
    JOURNAL OF ENDOCRINOLOGY, 1968, 42 (02) : 267 - &
  • [37] Thyroid cancer after exposure to radioactive 131I
    Holm, Lars-Erik
    ACTA ONCOLOGICA, 2006, 45 (08) : 1037 - 1040
  • [38] Uncertainties in determination of 131I activity in thyroid gland
    Osko, Jakub
    Golnik, Natalia
    Pliszczynski, Tomasz
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 516 - 519
  • [39] Establishing measurement traceability for national laboratories:: Results of an IAEA comparison of 131I
    Zimmerman, B. E.
    Meghzifene, A.
    Shortt, K. R.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 954 - 959
  • [40] COMPARISON OF I-123 AND I-131 FOR THYROID UPTAKE MEASUREMENT
    FILIATRAUT, AZ
    TETALMAN, M
    DARE, J
    SCHEU, J
    GRAY, B
    GERDES, S
    INVESTIGATIVE RADIOLOGY, 1976, 11 (05) : 414 - 414